Text · page 447 of 849
Read the whole document on one page (all 849 pages, each with its own heading)
UE EX. PIN CB UE sections 7209N and 7301 of the New York State Education Law for any person, unless acting under the direction of a registered architect, licensed engineer or land surveyor to alter this drawing. If altered such R.A., P.E. or L.L.S. shall affix his or her seal, signature, the date,the notation "Altered By" and a specific description of the alteration. RIM:683.34 G APPROX. LOCATION All Rights Reserved. Reuse of these documents without the expressed written permission of CARMINAWOOD DESIGN is prohibited. WARNING it is a violation of article 145 W N. INV:672.94 (18") ST Greensboro S. INV:673.10 (18") SA CB OE " RIM:680.53 32 UE 8'- N. INV:671.23 (18") EX 5' N .ST CB °-5 G 5.2 32' E OE 0 S. INV:671.23 (18") .N . 10 RIM:685.39 0W. AI N. INV:677.49 (18") L 87°-09'-45" S. INV:677.49 (16") E. INV:676.99 (4") UE LIMIT OF TREE CLEARING SA G UE OR T MH LO W Utica ACK T. RIM:685.89 IDE SETB BI 25' S UE NW. INV:676.14 (12") CH SE. INV:676.22 (12") UE 25' SI D PRO 1 .0 E PP . G OE SE T AR 20'x8.5' MAIL KIOSK SW PO /AT SA 'E BAC T UE Buffalo SED TA K EX. REBAR & BUS SHELTER W 1-S CHED 4.11' N. D N UE TO G O TI RY AR X. UE CA G E PA 5-U AGE LO O W 113°-18'-53" NIT S O PROPOSED 1-STORY 4-UNIT BUILDING BU SA S PR RK UE IL UE AP DIN 40' ING T FRO W/ATTACHED GARAGES G ILD NT G E PROPOSED 1-STORY 4-UNIT BUILDING EX. PIN O SET BU W RO BA I T CK UN ES UE PP 8' E.SA GSW -4 ARAG 0. UE Y W/ATTACHED GARAGES OR G -ST CHED A 1 SED TA EX 9' N OE UE PO W/AT D 5.8 /L .R . T O ±O PR 30' REAR SETBACK EB STOP (6 AR UE UE 6. 0 Multifamily Development SA SOE ') OE UE UE PP G T OE PP OE 1.0' E. OE W OE EX. IP. 14 11 OE 3.8 5° PP 7.27' NW. NW. COR. LOT 417 -0 BACK 6' UE LIMIT OF TREE CLEARING E SET 4'- SA W PARKING OE 25' SID MS 47 STOP LOT OE . S. LINE LOT 369 " G W ST 12" UE EX. IP. EA OE . AR N. INV: 660.98 (18" HDPE) BIT 25' SIDE SETBACK 12" 170°-37'-13" OE 89°-57'-36" APPROX. LOCATION CONTRACTOR TO VERIFY LIMITS OF HYD WG OF CEMETERY CEMETERY AND NOTIFY DESIGN SA S UE HEAD STONES NOT ENGINEER OF ANY POTENTIAL CONFLICTS STORM WATER LOCATED T OE 127°-49'-44" 1425 & 1475 Orchard Park Rd MANAGEMENT AREA 14" 28" 14" UE EX. IP. W. INV: 682.97 (12" HDPE) ST 23" UE COM 12" © CARMINA WOOD DESIGN PARKING S. INV: 662.31 (18" HDPE) West Seneca, NY LOT UE EX. IP. 729.52' . O/L STOP PART OF & MS 97.18' 146°-28'-21" D. W. LINE LOT 417 1' UE L-11442, P-836 29 9.7 PROPOSED 1-STORY 6 UNIT BUILDING UE PROPOSED 1-STORY 6 UNIT BUILDING W/ATTACHED GARAGES 38" W/ATTACHED GARAGES UE EXCEPTION COM 30" 149°-26'-50" 11" L-3327 10 24" EX. IP. P-87 30' REAR SETBACK PARKING Date 3. 2.04' NW. UE LOT 00 'D .& M S. SCRUB SHRUB WETLANDS (PSS) 36" 33 UE (APPROXIMATE LOCATION) 153°-18'-56" 8. " 14" 0' 10 D. 6'- & °-4 24" M S. 89 8" UE S. 113°-43'-57" 'M 18" 00 No. Description 729.26' 3. 11 UE COM REVISIONS: 5" T ND RA .B UE NE EX. REBAR LI S. N. M EXCEPTION .& 'D 8" 12" 11" O/L L-3036 70 2. 6" 8" 144.58' 12" 146.98' 150.63' 12" 26 153.06' 7" P-217 20" 6" & 89' S. 6" 12" D. 72. M 6" 13" 6" 0') EX. IP. 133°-32'-58" 0. 25' SIDE SETBACK 12.33' W. (7 COM EX. IP. 3.20' S. 275.56' D. & MS. AD 87°-23'-54" RO 20" N. INV: 669.78 (18" HDPE) RG SITE DATA ( REZONED TO C-1 (S) ) - 1425 & 1475 ORCHARD PARK RD - 16.59 ACRES GENERAL NOTES: Overall Site Plan SITE LEGEND BE MULTI-FAMILY ALLOWED BY SPECIAL PERMIT 1. INSTALL ALL MATERIALS TO MANUFACTURER'S RECOMMENDATIONS AND BEST STANDARDS OF TRADE INVOLVED. PROPERTY LINE MIN. LOT WIDTH = 50 FT FOR FIRST DWELLING UNIT, PLUS 10 FT FOR EACH ADDITIONAL UNIT NEED NOT EXCEED 100 FT 2. SUBSTITUTIONS SHALL BE MADE ONLY WITH OWNER'S APPROVAL AND BE OF EQUIVALENT QUALITY TO SCALE: 1"=50' WHAT IS SPECIFIED. MIN. LOT AREA = 8,000 SF FOR FIRST DWELLING UNIT, PLUS 5,000 FOR EACH ADDITIONAL DWELLING UNIT 3. WORK SHALL BE COMPLETED IN STRICT ACCORDANCE WITH ALL LOCAL CODES AND OSHA SAFETY PROPOSED CONCRETE CURB RULES AND REGULATIONS. FRONT SETBACK = 40 FT 4. VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AT THE SITE. NOTIFY OWNER & ENGINEER OF DISCREPANCIES IN CONDITIONS SHOWN ON DRAWINGS PRIOR TO PROCEEDING WITH THE WORK. DRAWING NAME: 1 SIDE SETBACK = 25 FT MIN. OR A DISTANCE EQUAL 2 HGT. TO OF SUCH BUILDING, WHICHEVER IS GREATER PROPOSED SIDEWALK / CONCRETE PAD 5. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF ANY EXISTING STRUCTURES TO REMAIN REAR SETBACK = 30 FT or EQUAL TO THE HEIGHT OF THE BUILDING AND ANY FINISH MATERIAL INSTALLED WHILE WORKING ON OTHER COMPONENTS. Overall Site Plan 6. CONTRACTOR SHALL KEEP JOB FREE OF DEBRIS AND MAKE FINAL CLEANUP TO SATISFACTION OF NUMBER OF PARKING SPACES MAXIMUM BUILDING HEIGHT = 40 FT (MULTI-FAMILY) OWNER. 27 7. CONTRACTOR SHALL ASCERTAIN THE LOCATION OF ALL UTILITIES PRIOR TO CONSTRUCTION SO THAT DRIVEWAY: 30 FT WIDE REQUIRED FOR MULTI-FAMILY THIS WORK WILL NOT DISTURB EXISTING LINES AND/OR INSTALLATIONS. COORDINATE ALL WORK WITHPROPOSED SIGN THE APPLICABLE UTILITY COMPANIES. DWELLING SIZE: 500 SF EACH MULTI-FAMILY UNIT 8. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS NECESSARY TO PERFORM THE WORK. PROPOSED STANDARD DUTY GROUP DWELLING: NO BUILDING SHALL BE NEARER TO ANY OTHER PRINCIPAL STRUCTURE THAN A DISTANCE EQUAL TO THE AVERAGE HEIGHT OF 9. ALL REASONABLE MEASURES SHALL BE TAKEN TO PROTECT EXISTING TREES WHICH ARE TO BE SUCH BUILDINGS ASPHALT PAVEMENT Date: 5/22/26 PRESERVED FROM ALL POSSIBLE TYPES OF ROOT, TRUNK, AND LIMB DAMAGE; INCLUDING BUT NOT Drawn By: A. Pandolfe LIMITED TO, RETAINING WALLS WHICH PREVENT FILLING ON TOP OF ROOTS OR EXCAVATING TREE ROOTS. Scale: As Noted PARKING CALCULATION: DENSITY CALCULATION (16.59 AC) PROPOSED LIGHT POLE MULTI-FAMILY: DRAWING NO. REQ'D = 8,000 SF FOR FIRST DWELLING UNIT, PLUS 5,000 FOR EACH REQ'D = 2 SPACES PER UNIT + 5/25 UNITS VISITORS ADDITIONAL DWELLING UNIT C-100 NOTES: REQ'D = 2 SPACES x 29 UNITS + (29/25 x645)SPACES = NOTE: BOUNDARY AND TOPOGRAPHIC INFORMATION PROVIDED BY OTHERS, ALLOWED NUMBER OF UNITS: 1. ALL RADII SHALL BE 3'-0" UNLESS OTHERWISE NOTED. CARMINA WOOD DESIGN ASSUMES NO RESPONSIBILITY FOR ITS ACCURACY. TOTAL PROVIDED = 65 SPACES + 42 GARAGE SPACES 107 SPACES = 1ST UNIT: 722,660 SF - 8,000 SF = 714,660 SF REMAINING 2. ALL DISTURBED AREAS: SHALL HAVE 4" MIN. OF TOPSOIL & SEED. ADDITIONAL UNITS: 714,660 SF / 5,000 SF = 142 UNITS 3. ALL DIMENSIONS FROM PROPERTY LINES SHALL BE MEASURED PERPENDICULAR TO THE PROPERTY LINE. 50 0 50 100Ft. 4. CENTER ENTRANCE SIDEWALKS ON DOOR OPENINGS. 50' Project No: 23-4121 TOTAL ALLOWED UNITS = 143 UNITS 5. BUILDING DIMENSIONS ARE APPROXIMATE, REFER TO ARCHITECTURAL DRAWINGS FOR LAYOUT DIMENSIONS. Page 447 of 849