CARMINA WOOD DESIGN  Project No.:  23-4121  Date:  5/22/2026
  80 Silo City Row, Suite 100  Project Name:  Multifamily Development
  Buffalo, New York 14203  Project Address: 1425-1475 Orchard Park Road - West Seneca
  (716) 842-3165  Subject:  Sanitary Sewer Demand Calcs
  FAX (716) 842-0263  Sheet:  1  of  1

Sanitary Sewage Demand Calculations:

  Proposed Townhomes

  220 gal/d/unit  x  29 units  =  6,380  gpd  *use 220 gallons per unit per day (2-bdrm)

Find Peak Sanitary Demand:

  Peaking Factor based on Population:
  Total demand:  6,380 gpd  / 51.96 gpcd  =  123 per capita

  Population (P)  =  123 people

  Peaking Factor : (18 +√P) / (4 + √P )  where P is in thousands

  Peaking Factor =  4.22

  Peak Sanitary Demand  =  6,380 x  4.22  =  26,911 gpd
  =  0.027 MGD
  =  0.042 cfs

Required Infiltration and Inflow Mitigation:

  Mitigation Fee  =  $2.40 /gal  =  $15,312.00

  Page 475 of 849