Southtowns Record

PBA06.11.2026packet

Government
Town of West Seneca
Board
Planning Board
Meeting
Jun 11, 2026, 6:00 p.m.
Posted by publisher
Jun 3, 2026
Kind
Agenda packet
Topics
Water, sewer and drainage, Housing, Zoning and land use, Roads and traffic, Parks and recreation, Budget and taxes, Public safety

Original document

Same meeting

Text · page 538 of 849

Read the whole document on one page (all 849 pages, each with its own heading)

23-4121 storm calcs - Proposed  Type II 24-hr 10-Year Rainfall=3.14"
Prepared by Carmina Wood Design  Printed 5/14/2026
HydroCAD® 10.20-8a s/n 05019 © 2025 HydroCAD Software Solutions LLC  Page 16

  Summary for Subcatchment 1S: Proposed - North

[47] Hint: Peak is 1821% of capacity of segment #3
[47] Hint: Peak is 242% of capacity of segment #4
[47] Hint: Peak is 203% of capacity of segment #5

Runoff  =  7.22 cfs @ 12.18 hrs, Volume=  26,940 cf, Depth= 2.03"
  Routed to Pond 1P : Detention Pond

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.50-70.02 hrs, dt= 0.04 hrs
Type II 24-hr 10-Year Rainfall=3.14"

  Area (sf)  CN  Description
  32,787  98  Roofs, HSG D
  45,906  98  Paved parking, HSG D
*  3,518  98  Sidewalk, HSG D
  77,291  80  >75% Grass cover, Good, HSG D
  159,502  89  Weighted Average
  77,291  48.46% Pervious Area
  82,211  51.54% Impervious Area

  Tc Length Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  6.4  21 0.0090  0.05  Sheet Flow,
  Grass: Dense n= 0.240 P2= 2.50"
  15.1  65 0.0100  0.07  Sheet Flow,
  Grass: Dense n= 0.240 P2= 2.50"
  1.5  182 0.0050  2.02 0.40 Pipe Channel, 6" @ 0.5%
  6.0" Round Area= 0.2 sf Perim= 1.6' r= 0.13'
  n= 0.013 Corrugated PE, smooth interior
  0.3  70 0.0070  3.80 2.98 Pipe Channel, 12" @ 0.7%
  12.0" Round Area= 0.8 sf Perim= 3.1' r= 0.25'
  n= 0.013 Corrugated PE, smooth interior
  1.5  400 0.0100  4.54 3.56 Pipe Channel, 12" @ 1.0%
  12.0" Round Area= 0.8 sf Perim= 3.1' r= 0.25'
  n= 0.013 Corrugated PE, smooth interior
  24.8  738 Total