23-4121 storm calcs - Proposed  Type II 24-hr 100-Year Rainfall=5.23"
Prepared by Carmina Wood Design  Printed 5/14/2026
HydroCAD® 10.20-8a s/n 05019 © 2025 HydroCAD Software Solutions LLC  Page 31

  Time span=0.50-70.00 hrs, dt=0.04 hrs, 1739 points
  Runoff by SCS TR-20 method, UH=SCS, Weighted-CN
  Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method

Subcatchment 1S: Proposed - North  Runoff Area=159,502 sf 51.54% Impervious Runoff Depth=3.99"
  Flow Length=738' Tc=24.8 min CN=89 Runoff=13.94 cfs 53,068 cf

Subcatchment 2S: Proposed - South  Runoff Area=93,939 sf 49.41% Impervious Runoff Depth=3.99"
  Flow Length=627' Tc=19.8 min CN=89 Runoff=9.33 cfs 31,254 cf

Subcatchment 3S: Direct  Runoff Area=21,732 sf 0.00% Impervious Runoff Depth=3.09"
  Flow Length=58' Tc=7.8 min CN=80 Runoff=2.52 cfs 5,604 cf

Pond 1P: Detention Pond  Peak Elev=674.73' Storage=34,966 cf Inflow=22.95 cfs 84,322 cf
  Outflow=3.45 cfs 84,322 cf

  Total Runoff Area = 275,173 sf Runoff Volume = 89,926 cf Average Runoff Depth = 3.92"
  53.25% Pervious = 146,543 sf 46.75% Impervious = 128,630 sf