23-4121 storm calcs - Proposed  Type II 24-hr 100-Year Rainfall=5.23"
Prepared by Carmina Wood Design  Printed 5/14/2026
HydroCAD® 10.20-8a s/n 05019 © 2025 HydroCAD Software Solutions LLC  Page 34

  Summary for Subcatchment 2S: Proposed - South

[47] Hint: Peak is 1092% of capacity of segment #3
[47] Hint: Peak is 293% of capacity of segment #4
[47] Hint: Peak is 250% of capacity of segment #5

Runoff  =  9.33 cfs @ 12.12 hrs, Volume=  31,254 cf, Depth= 3.99"
  Routed to Pond 1P : Detention Pond

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.50-70.02 hrs, dt= 0.04 hrs
Type II 24-hr 100-Year Rainfall=5.23"

  Area (sf)  CN  Description
  22,791  98  Roofs, HSG D
  22,002  98  Paved parking, HSG D
*  1,626  98  Concrete, HSG D
  47,520  80  >75% Grass cover, Good, HSG D
  93,939  89  Weighted Average
  47,520  50.59% Pervious Area
  46,419  49.41% Impervious Area

  Tc Length Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  1.4  10 0.0900  0.12  Sheet Flow,
  Grass: Dense n= 0.240 P2= 2.50"
  15.6  43 0.0040  0.05  Sheet Flow,
  Grass: Dense n= 0.240 P2= 2.50"
  1.3  194 0.0050  2.45 0.85 Pipe Channel, 8" @ 0.5%
  8.0" Round Area= 0.3 sf Perim= 2.1' r= 0.17'
  n= 0.013 Corrugated PE, smooth interior
  0.9  209 0.0080  4.06 3.19 Pipe Channel, 12" @ 0.8%
  12.0" Round Area= 0.8 sf Perim= 3.1' r= 0.25'
  n= 0.013 Corrugated PE, smooth interior
  0.6  171 0.0110  4.76 3.74 Pipe Channel, 12" @ 1.1%
  12.0" Round Area= 0.8 sf Perim= 3.1' r= 0.25'
  n= 0.013 Corrugated PE, smooth interior
  19.8  627 Total

  Page 556 of 849