Rustys_Post-Construction - Copy  Type II 24-hr 25-yr Rainfall=3.84"
Prepared by Waves AE  Printed 7/29/2026
HydroCAD® 10.20-7a s/n 13900 © 2025 HydroCAD Software Solutions LLC  Page 9

  Summary for Subcatchment 2: Subcat 2

Runoff  =  1.32 cfs @ 11.97 hrs, Volume=  2,586 cf, Depth> 1.91"
  Routed to Pond 6P : INFIL. BED 5

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Type II 24-hr 25-yr Rainfall=3.84"

  Area (sf)  CN  Description
  10,593  73  Brush, Good, HSG D
  2,424  98  Paved parking, HSG D
  3,239  98  Unconnected pavement, HSG D
  16,257  82  Weighted Average
  10,593  65.16% Pervious Area
  5,663  34.84% Impervious Area
  3,239  57.20% Unconnected

  Tc Length  Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  6.0  Direct Entry,

  Subcatchment 2: Subcat 2
  Hydrograph

  Runoff
  1.32 cfs
  Type II 24-hr
  25-yr Rainfall=3.84"
  1
  Runoff Area=16,257 sf
  Runoff Volume=2,586 cf
  Flow (cfs)

  Runoff Depth>1.91"
  Tc=6.0 min
  CN=82

  0
  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20
  Time (hours)