sections 7209N and 7301 of the New York State Education Law for any person, unless acting under the direction of a registered architect, licensed engineer or land surveyor
to alter this drawing. If altered such R.A., P.E. or L.L.S. shall affix his or her seal, signature, the date,the notation "Altered By" and a specific description of the alteration.
All Rights Reserved. Reuse of these documents without the expressed written permission of CARMINAWOOD DESIGN is prohibited. WARNING it is a violation of article 145

  Greensboro
  Utica
  Buffalo
  NOTE: CONTRACTOR SHALL APPLY FOR
  AND OBTAIN A NYSDOT HIGHWAY WORK
  PERMIT FOR UTILITY WORK - PERM 32
  FOR ALL UTILITY CONNECTIONS WITHIN
  THE UNION ROAD RIGHT-OF-WAY

  8"x6" WYE, INV 522.8±
  CONTRACTOR TO VERIFY DEPTH
  10 LF SDR-35 PVC  PRIOR TO CONSTRUCTION
  SANITARY SEWER
  LATERAL @ 1.O% MIN.  23 LF SDR-35 PVC
  SANITARY SEWER
  LATERAL @ 1.O% MIN.
  28 LF SDR-35 PVC
  SANITARY SEWER
  LATERAL @ 1.O% MIN.

  1" TYPE "K" COPPER
  DOMESTIC SERVICE  C.O.
  1" CURB STOP &  (MIN. 5' COVER)  C.O.
  BOX (BY ECWA)
  18" MIN. VERTICAL  8
  SEPARATION  INSTALL 1" RPZ
  1" TAPPING SADDLE AND  & METER INSIDE
  CORP. STOP (BY ECWA)  UTILITY ROOM

  Proposed Bank
  PROPOSED
  INSTALL C.O.,  SINGLE-STORY BANK
  TRAP & VENT  EXISTING 2-STORY
  IN GREENSPACE  INV 525.40 2,750± S.F.  OFFICE BUILDING
  F.F.E. = 530.40
  3,150 S.F. FOOTPRINT
  7 LF SDR-35 PVC  F.F.E. = 530.90
  SANITARY SEWER
  LATERAL @ 1.O% MIN.
  © CARMINA WOOD DESIGN

  APPROXIMATE LOCATION OF EX. 6"

  West Seneca, NY
  1465 Union Road
  CIP WATER MAIN. CONTRACTOR TO
  VERIFY SIZE AND LOCATION PRIOR
  TO CONSTRUCTION.

  COORDINATE GAS, ELECTRIC AND TELEPHONE
  CONDUIT SIZE AND LOCATIONS WITH UTILITY

  STOP
  COMPANIES AND MEP PLANS

  STOP

  Date
  DO NOT
  ENTER

  No. Description
  REVISIONS:
  15
  NOTES:

  1.  ALL SANITARY SEWER CONSTRUCTION SHALL CONFORMTOWNTOOF WEST SENECA

  ARY
  CTION
  SPECIFICATIONS AND DETAILS, AND ERIE COUNTY DEPARTMENT OF HEALTH RULES AND
  REGULATIONS.

  2.  PRIOR STARTING ANY WORK ASSOCIATED WITH OR NEAR EXISTING SANITARY MANHOLES,

  CONSTRU
  THE CONTRACTOR SHALL MEET WITHTOWN
  THE OF WEST SENECA
  TO DISCUSS AND AGREE

  PRELIMIN
  TO THE WORK.
  PROPOSED UTILITY LEGEND
  POTENTIAL FUTURE  3.  FILL SHALL BE PLACED AND SATISFACTORILY COMPACTED PRIOR TO INSTALLATION OF
  PROPOSED STORM SEWER  ST
  PARKING EXPANSION  UTILITIES, AND MUST BE APPROVED BY THE SUPERVISING PROJECT ENGINEER.
  PROPOSED SANITARY SEWER  6" SA

  NOT FOR
  4.  ALL OTHER REQUIRED PERMITS BY THE STATE OF NEW YORK, COUNTY OFTOWN
  ERIE AND
  OF WEST SENECA
  ARE THE RESPONSIBILITY OF THE CONTRACTOR/DEVELOPER.
  PROPOSED WATERLINE  1" W

  UTILITY NOTES:  PROPOSED CATCH BASIN  CB
  1.  FOR ALL SANITARY SEWERS, INSTALL SELECT FILL IN PAVED AREAS, EXTEND 5' MIN. BEYOND PAVEMENT LIMITS
  PROPOSED YARD DRAIN  YD
  2.  BUILDINGS TO HAVE6"AHOUSE TRAP, VENT AND CLEANOUT INSTALLED AT ENTRANCE POINT. INVERT ELEVATION
  TO BE5' MIN.BELOW F.F.E. OF THE BUILDING. PIPE TO
  6" SDR-35
  BE PVC @ 1.0% MIN WITH MIN 4' OF COVER. ADD
  ADDITIONAL CLEANOUTS @ 100' MAX. SPACING 6" LATERALS
  FOR  OVER 90' IN LENGTH.  PROPOSED MANHOLE  MH
  DRAWING NAME:
  3.  COORDINATE GAS & ELEC. METER BANK LOCATIONS ON BUILDINGS WITH M.E.P. PLANS & UTILITY CO.'S.
  PROPOSED HYDRANT ASSEMBLY
  4.  COORDINATE LOCATION OF CTV & TELEPHONE SERVICE TO BUILDINGS WITH M.E.P. PLANS AND UTILITY CO.'S.
  Utility Plan
  5.  ANY EXISTING UTILITIES WHICH ARE TO BE ABANDONED AND FALL UNDER PAVEMENT OR BUILDINGS SHALL BE  PROPOSED GATE VALVE  GV
  REMOVED VS. BEING ABANDONED UNLESS THOSE UTILITIES ARE FILLED WITH FLOWABLE FILL.
  NOTE: FOR PROPOSED VALVE BOXES, CLEANOUTS, ETC., INSTALL A
  6.  EXISTING GAS SERVICES TO REMAIN UNLESS OTHERWISE NOTED. ANY PORTIONS TO BE RELOCATED SHALL BE  3,000 PSI CONCRETE COLLAR AROUND THE ITEM AT GRADE. THE
  COORDINATED WITH NATIONAL FUEL GAS.  COLLAR SHALL BE A MINIMUM OF 6" WIDER, ON ALL SIDES, THAN THE
  BOX, CLEANOUT, ETC. THE COLLAR SHALL BE A MINIMUM OF 6" THICK.
  7.  ALL UNDERGROUND TELEPHONE SERVICES SHALL REMAIN AND BE PROTECTED DURING CONSTRUCTION.  Date:  1/20/26
  Drawn By:  A. Pandolfe

  Utility Plan  8.  A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES OF VERTICAL SEPARATION MUST BE MAINTAINED BETWEEN ALL
  SANITARY SEWER AND WATER SERVICES.  NOTE: BOUNDARY AND TOPOGRAPHIC INFORMATION PROVIDED BY OTHERS,
  CARMINA WOOD DESIGN ASSUMES NO RESPONSIBILITY FOR ITS ACCURACY.
  Scale:
  DRAWING NO.
  As Noted

  9. ERIE COUNTY WATER AUTHORITY (ECWA) IS TO BE NOTIFIED A MINIMUM OF 48-HOURS PRIOR TO STARTING THE
  SCALE: 1"=30'

  C-400
  CONNECTION TO THE NEW WATER SERVICE.  20  0  20  40Ft.
  20'
  10. SELECT BACKFILL IS REQUIRED FOR ALL UTILITIES (GAS, WATER, STORM, SANITARY) THAT CROSS THROUGH
  PAVEMENT AREAS.
  Project No:  25-4181