GENERAL NOTES A. REFER TO PROJECT MANUAL FOR ADDITIONAL REQUIREMENTS. B. SITE CONDITIONS BASED UPON SURVEY PROVIDED BY OWNER. FIELD VERIFY EXISTING CONDITIONS BY DETAILED INSPECTION PRIOR TO SUBMITTING BID AND BEGINNING CONSTRUCTION. NOTIFY ARCHITECT IF EXISTING CONDITIONS DEVIATE W E SYMBOL LEGEND SUBSTANTIALLY FROM THOSE INDICATED HEREIN. REFER TO SURVEY FOR EXISTING CONDITION SYMBOLS LEGEND NEW UTILITIES (SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) KEY NOTES WATER SERVICE WATER: S S SANITARY SEWER 1 PROPOSED ± 70 LF OF 2-INCH “TYPE K” COPPER POTABLE WATER SERVICE IN ACCORDANCE WITH UTILITY PROVIDER SPECIFICATIONS. STORM SEWER GC TO COORDINATE FINAL PENETRATION LOCATIONS & SIZE WITH NAD83 E&T U/G ELECTRIC ARCHITECT/MEP PLANS PRIOR TO CONSTRUCTION. GC TO COORDINATE WATER CONNECTION AND INSTALLATION WITH UTILITY T U/G PHONE (BY PHONE CO.) PROVIDER PRIOR TO CONSTRUCTION FOR ANY SPECIAL OH OVERHEAD ELECTRIC CONTRACTOR PERMITS, INSPECTIONS, RESPONSIBILITIES, OR G GAS SERVICE (BY GAS CO.) SUBMITTAL REQUIREMENTS. C/O SANITARY CLEANOUT 2 EXISTING WATER SHUT OFF VALVE TO REMAIN S SANITARY MANHOLE SAW CUT 3 PROPOSED BACKFLOW PREVENTION AND RPZ LOCATED WITH IN BUILDING. REFER TO ARCHITECT/MEP PLANS BY OTHERS FOR SPECIFICATIONS AND REQUIREMENTS. 4 EXISTING WATER MAIN (TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION) NOT USED 5 PROPOSED 1" IRRIGATION LINE. GC TO COORDINATE FINAL PENETRATION LOCATION & SIZE WITH ARCHITECT/MEP PLANS PRIOR TO CONSTRUCTION. APPROXIMATE LOCATION OF SEPARATE S88°43'30"E BACKFLOW/METERING TO BE CONFIRMED WITH MEP PLANS. GC TO 357.97' ENSURE AT LEAST (1) 4"PVC CONDUIT IS AVAILABLE UNDER ALL LOD ACCESS DRIVES AND PARKING LOTS FOR IRRIGATION INSTALLATION. LOD LOD LOD LOD GAS: LOD LOD LOD LOD LOD LOD LOD 6 PROPOSED GAS SERVICE LINE AND VALVE CONNECTION IN LOD LOD ACCORDANCE WITH UTILITY PROVIDER SPECIFICATIONS. GC TO COORDINATE FINAL PENETRATION CONNECTION POINTS AND SIZE LOD WITH ARCHITECT/MEP PLANS PRIOR TO CONSTRUCTION. GC TO 13 13 13 COORDINATE GAS SERVICE CONNECTION AND INSTALLATION WITH UTILITY PROVIDER PRIOR TO CONSTRUCTION FOR ANY SPECIAL LOD CONTRACTOR PERMITS, INSPECTIONS, RESPONSIBILITIES, OR SUBMITTAL REQUIREMENTS. LOD SITE UTILITY PLAN SEWER: ABB LOD LOD 7 PROPOSED ± 35 LF OF 4" SDR-21 PVC @ 2.0% AND 5' MIN DEPTH IN CNDT ACCORDANCE WITH UTILITY PROVIDER SPECIFICATIONS. GC TO COORDINATE FINAL PENETRATION LOCATIONS, SIZE, AND DEPTH N00°05'25"W WITH ARCHITECT/MEP PLANS PRIOR TO CONSTRUCTION. GC TO LOD (ASP WAY ED LIM (30 M 94.90' (TWOPH SPE COORDINATE SEWER CONNECTION AND INSTALLATION WITH UTILITY LOD (66' W 12 CNDT PROVIDER PRIOR TO CONSTRUCTION FOR ANY SPECIAL O LOD HAL CONTRACTOR PERMITS, INSPECTIONS, RESPONSIBILITIES, OR LANDS N/F OF SUBMITTAL REQUIREMENTS. IDE R DWA TT R T RORAFFIC)T) DANIEL ZIELINSKI LOD 8 PROPOSED CONNECTION TO EXISTING MUNICIPAL SEWER ±598.80 IN D.B. 11091, PG. 698 NEW O'REILLY AUTO PARTS STORE LOD 1255,1265,1269,1271 ABBOTT ROAD ACCORDANCE WITH UTILITY PROVIDER SPECIFICATIONS. GC TO T .O.W Y) TM #142.07-2-8 A COORDINATE SEWER CONNECTION AND INSTALLATION WITH UTILITY HSE #1255 ABBOTT ROAD 13 PROVIDER PRIOR TO CONSTRUCTION FOR ANY SPECIAL .) LOD CONTRACTOR PERMITS, INSPECTIONS, RESPONSIBILITIES, OR OAD SUBMITTAL REQUIREMENTS. LOD S12°56'27"E I 220.71' 9 PROPOSED UTILITY CROSSING. GC TO ENSURE MINIMUM 18" VERTICAL SEPARATION BETWEEN WATER & SEWER SERVICE LOD LATERALS. NOT USED D LO LOD LOD LOD LOD LOD D INV IN 598.70 (12") A-30 10 PROPOSED SANITARY SEWER CLEANOUT ET& N88°08'23"W LOD LOD C ELECTRIC: 257.94' 15 PORTAL: 52'-0" 11 PROPOSED ELECTRIC SERVICE CONNECTION TO THE BUILDING IN BUILDING TYPE: PEMB ACCORDANCE WITH UTILITY PROVIDER SPECIFICATIONS. GC TO LACKAWANNA, NY 17 SQ. FT. = 7,650 COORDINATE FINAL EQUIPMENT LOCATIONS AND SERVICE ET&C 15 CONNECTION POINT WITH ARCHITECT/MEP PLANS PRIOR TO LOD LOD OH 85'-0" X 90'-0" CONSTRUCTION. GC TO COORDINATE ELECTRIC SERVICE OH CONNECTION AND INSTALLATION WITH UTILITY PROVIDER PRIOR TO O'Reilly Auto Parts CONSTRUCTION FOR ANY SPECIAL CONTRACTOR PERMITS, OH INSPECTIONS, RESPONSIBILITIES, OR SUBMITTAL REQUIREMENTS. ET&C EGRESS LOD LOD DOOR 12 PROPOSED (2) 4” CONDUIT SLEEVES FOR SITE LIGHTING OR SIGNAGE ELECTRICAL NEEDS. REFER TO ARCHITECT/MEP PLANS FOR N00°18'33"E ADDITIONAL SITE ELECTRICAL REQUIREMENTS TO LIGHT POLES, OH ET&C PROJECT: 118.99' 15 SIGNAGE, OR OTHER SITE FEATURES. LOD LOD 13 PROPOSED LIGHT POLE. GC TO COORDINATE WITH MEP PLAN FOR FINAL POLE LOCATIONS, FIXTURE SPECIFICATIONS, FOUNDATION ET 11 DETAILS, AND ELECTRICAL ROUTING AND REQUIREMENTS. OH 15 14 &C LOD AUTO PARTS LOD 5 COMMUNICATIONS: DOOR INV: 599.50 PROPOSED TELEPHONE/COMMUNICATION SERVICE CONNECTION TO 14 DEALER 3 W THE BUILDING IN ACCORDANCE WITH UTILITY PROVIDER 10 OH SPECIFICATIONS. GC TO COORDINATE FINAL EQUIPMENT LOCATIONS LOD LOD W C/O AND SERVICE CONNECTION POINTS WITH ARCHITECT/MEP PLANS LOD PRIOR TO CONSTRUCTION. GC TO COORDINATE SERVICE CONNECTION AND INSTALLATION WITH UTILITY PROVIDER PRIOR TO G LOD CONSTRUCTION FOR ANY SPECIAL CONTRACTOR PERMITS, S OH 1 INSPECTIONS, RESPONSIBILITIES, OR SUBMITTAL REQUIREMENTS. LOD W 6 13 16 STORMWATER: 7 15 PROPOSED ROOF DRAINAGE DOWNSPOUT. GC TO COORDINATE LOD G S FINAL LOCATIONS AND SIZE WITH ARCHITECT/MEP PLANS PRIOR TO OH W LOD CONSTRUCTION. 8 S 16 PROPOSED OVERHEAD WIRE INSTALLED BY ELECTRIC SERVICE LOD PROVIDER M:\MA\2025\NYB250127.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PROP-NYB250127.00-0A----->LAYOUT: C4.1 UTIL 17 2 OH D LO 17 PROPOSED UTILITY POLE INSTALLED BY ELECTRIC SERVICE PROVIDER OH LO P.O.B. ENVIRONMENTAL GENER D SURVEYOR'S DESCRIPTION LOD LOD LOD LOD LOD OH LOD LOD LOD LOD LOD LOD JULIAN AVE(50' WIDE R.O.W.) OH N89°41'29"W NOTES 150.00' (ASPHALT ROADWAY) OH A. AN ENVIRONMENTAL ANALYSIS HAS BEEN PERFORMED ON (TWO WAY TRAFFIC) OH THE EXISTING SITE. REFER TO PROJECT MANUAL. (30 MPH SPEED LIMIT) OH B. IF THIS PROJECT CONTAINS HAZARDOUS MATERIALS, CONTRACTOR TO PROVIDE WORK REQUIRED FOR PROPER REMOVAL, HANDLING, AND DISPOSAL PER ENVIRONMENTAL ANALYSIS RECOMMENDATIONS. PLAN REFERENCES · REFER TO GENERAL NOTES SHEET FOR ADDITIONAL NOTES COMM # XXXX · THIS PLAN TO BE UTILIZED OR UTILITIES PURPOSES ONLY DATE: 02/24/2026 REVISION DATE: CAUTION: INFORMATION ON THIS DRAWING CONCERNING TYPE AND LOCATION OF UNDERGROUND AND OTHER UTILITIES IS NOT GUARANTEED TO BOHLER PLANNING, LANDSCAPE ARCHITECTURE, ENGINEERING AND SURVEYING NY, PLLC BE ACCURATE OR ALL INCLUSIVE. 17 COMPUTER DRIVE WEST, ALBANY, NY 12205 1 SITE UTILITY PLAN THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN Phone: (518) 438-9900 Fax: (518) 438-0900 C4.1 DETERMINATION AS TO THE TYPE www.BohlerEngineering.com Mar 05, 2026 AND LOCATION OF UNDERGROUND 20 10 5 0 20 AND OTHER UTILITIES AS MAY BE NECESSARY TO AVOID DAMAGE C4.1SCALE: 1"=20'-0" PROJECT NO: NYB250127.00-0A DRAWN BY / CHECKED BY: KLR/TCF SCALE: CAD I.D.: 1" SCALE = 20' P-CIVL-PROP THERETO. SCALE: 1" = 20'