Southtowns Record

TBA Agenda Packet 5.11.26

Government
Town of West Seneca
Board
Town Board
Meeting
May 11, 2026, 6:00 p.m.
Posted by publisher
May 9, 2026
Kind
Agenda packet
Topics
Budget and taxes, Parks and recreation, Water, sewer and drainage, Zoning and land use, Public safety, Roads and traffic, Audits and oversight, Short-term rentals, Housing

Original document

Same meeting

Text · page 110 of 280

Read the whole document on one page (all 280 pages, each with its own heading)

CoolToppers® 154397 CoolToppers,
  Single Post Shade

Parts List  Installation Instructions
Part#  Description  Qty.  1)  Dig footing hole as shown.
152833  Umbrella Ext. Arm Weldt., Specify Color......................4
153560  Clamp, Specify Color.....................................................2  2)  Place post in footing hole. With post braced plumb pour concrete
153663  Brace (Installation & Removal), Specify Color.............4  footing. NOTE: Allow concrete footing to cure for a minimum of 72
154136  Post, Specify Color.........................................................1  hours before proceeding.
210962  LSI Shade 12x12 Cooltopper .......................................1
  3)  Attach clamps to post at height shown using 3/8” x 1 1/8” BHCS w/pin
175824  Single Post Shade Hardware Package ......................1  with 3/8” SAE flat washers and 3/8” standard hex nuts with 3/8” SAE flat
  100322  1
  /2” Standard Hex Nut, SST...........................................8  washers. Refer to the Upper Arm Attachment Detail. NOTE: Orientate
  100323  5
  /8” Standard Hex Nut, SST............................................8  clamp flanges in the direction you want extension arms to face.
  100327  3
  /8” Standard Hex Nut, SST............................................8
  100365  3
  /8” SAE Flat Washer, SST.............................................16  4)  Lift extension arm into position and attach the top bolt only to clamp
  100366  5
  /8” Flat Washer, SST......................................................8  flange, using 5/8” x 1 1/2” BHCS w/pin with 5/8” flat washer and 5/8”
  175652  5
  /8” Lock Washer, SST....................................................8  standard hex nut with 5/8” lock washer. Attach remaining extension
  127547  3
  /8” x 1 1/8” BHCS w/Pin, SST........................................8  arms following the same sequence. Refer to the Upper Arm Attachment
  127551  5
  /8” x 1 1/2” BHCS w/Pin, SST........................................8  Detail. NOTE: Lightly tighten bolts, so arms move freely up and down.
  For ease of installation a 12’-16’ ladder or bucket lift is recommended.
  5)  Lift extension arm up and attach temporary brace to clamp flange and
Specifications  extension arm using 1/2” standard hex nuts. Attach temporary braces
  to remaining extension arms following the same sequence. Refer to
  CoolToppers  the Brace Attachment Detail.
  Shade Top:  High-density polyethylene with ultra violet additives.
  All corners to be strengthened with 16 oz. non-tear  6)  Place the shade over the extension arms and attach each corner to
  vinyl material. Protective webbing is sewn into all  extension arm pin.
  areas where steel cable enters/exits cloth pockets.
  Live loads 20 psf. Wind design speed withstands  7)  Remove temporary braces from extension arms and clamps. NOTE:
  up to 90 mph. Uplift 19 psf. Snow loads 5 psf. Tear  Retain temporary braces for future use.
  strength warp 221 lb. and weft 463 lb.. Burst strength
  38 PSIA.  8)  Simultaneously pull the arms down and bolt the remaining hole in
  the arm to post flange using 5/8” x 1 1/2” BHCS w/pin with 5/8” flat
 Extension Arms:  Weldment comprised of 2.875” O.D. RS-40 (.149” -
  .182”) galvanized steel tubing, 1/4” steel plate and 1/4”  washers and 5/8” standard hex nuts with 5/8” lock washers. Refer to the
  diameter carbon steel J-hooks. Finish: ProShield®,  Lower Arm Attachment Detail. Final tighten hardware. NOTE: When
  color specified.  CoolToppers shade top is properly tensioned, it should be difficult to
  insert fingers between fabric and top of post. To increase tension to
  Clamp:  Weldment comprised of 1/4” x 3” HRPO flat steel
  and 1/4” HRPO steel plate. Finish: ProShield, color  shade top, loosen clamp fasteners and pull down on extension arms
  specified.  and clamps. Retighten clamp fasteners.
CoolToppers Post: Weldment comprised of 5” O.D. x 11 GA (.120”)  9)  Thread cable along perimeter of fabric.
  galvanized steel tubing and 1/4” steel plate. Finish:
  ProShield, color specified  10) Cable should lay on top of fabric at the corners. Pull cable tight by
  hand and attach with cable clamp provided. Refer to the Cable Clamp
  Fasteners: Primary fasteners shall be socketed and pinned tam-  Attachment Detail.
  perproof in design, stainless steel (SST) per ASTM F
  879 unless otherwise indicated (see specific product
  installation/specifications).
Installation Time:  Approx. 10 Hours
  Actual Size:  12’ (3,65 m) x 12’ (3,65 m)
  Concrete:  9.5 cu. ft.
  Weight:  266 lbs.

  ECO 0110949 Document 35525200 replaces 30846900. Update instructions steps and time.

  Page 5
  Page 110 of 280