Water Quality Peak Flow Calclations

NYSDEC Water Quality Volume (WQv) & Water Quality Peak Flow (Qp) Calculation
  Worksheet (REQUIRED Qp)

PROJECT INFORMATION
  Total Drainage Area  A:  2.09 ac
  Impervious Area  I:  1.90 ac
  Percent Impervious  90.9 %
  NYSDEC 90% Rainfall  P:  1.00 in.
  Time of Concentration  Tc:  0.27 hrs
  Rv:  0.87
WATER QUALITY VOLUME
  Water Quality Volume WQv=([(P)*(Rv)*(A)]/12)*43560  WQv:  6,587 cf

WATER QUALITY PEAK FLOW (NEW DEVELOPMENT)
  Runoff Volume Q=WQv/(A*3600)  Q:  0.87 in.
  2  ½
  CN=1000/(10+5*P+10*Q-10(Q +1.25*Q*P) )  CN:  98.80
  CN Rounded  CN:  99
  CN < or = 98  CN:  98
  Initial Abstraction (Ia=200/CN-2)  Ia:  0.04 in.
  RATIO R=Ia/P  R:  0.04
  2
  C0 = A*R +B*R +C  C0:  2.54
  2
  C1 = A*R +B*R +C  C1:  -0.58
  2
  C2 = A*R +B*R +C  C2:  -0.17
  2
  Unit Peak Discharge qu=10^(C0+C1*Log(Tc)+C2*(log(Tc)) )  qu:  663.03 cfs/mi2/in
  Water Quality Peak Flow Qp=qu*A*Q/640 (100%)  Qp:  1.88 cfs

REDVELOPMENT
  Impeverious Area Reduction  IC  0.00 %
  WQv Treatment by Standard Practice  SP  0.00 %
  Runoff Reduction  RR  0.00 %
  Req. WQv% By Alt. Practice AP=(25-(% IC+%SP+%RR))*3:  AP  75.0 %
  Required Water Quality Peak Flow RD QP=(Qp*AP):  RD Qp:  1.41 cfs

Page 1 of 1

  Page 172 of 359