D_App D_Pre-Development Model  NY-West Seneca 24-hr S1 10-yr Rainfall=3.14"
Prepared by Labella Associates  Printed 4/17/2026
HydroCAD® 10.20-7a s/n 09581 © 2025 HydroCAD Software Solutions LLC  Page 10

  Summary for Subcatchment ES-1: W Site

Runoff  =  12.32 cfs @ 12.15 hrs, Volume=  0.961 af, Depth= 1.49"
  Routed to Reach AP-1 : Cayuga Creek

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs
NY-West Seneca 24-hr S1 10-yr Rainfall=3.14"

  Area (sf)  CN  Description
  38,223  98  Paved parking, HSG D
  298,971  80  >75% Grass cover, Good, HSG D
  337,194  82  Weighted Average
  298,971  88.66% Pervious Area
  38,223  11.34% Impervious Area

  Tc Length Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  8.5  100 0.0450  0.20  Sheet Flow, SF
  Grass: Short n= 0.150 P2= 2.20"
  5.3  271 0.0148  0.85  Shallow Concentrated Flow, SCF
  Short Grass Pasture Kv= 7.0 fps
  0.2  20 0.1500  1.94  Shallow Concentrated Flow, SCF
  Woodland Kv= 5.0 fps
  14.0  391 Total

  Subcatchment ES-1: W Site
  Hydrograph

  Runoff
  13  12.32 cfs
  12  NY-West Seneca 24-hr S1 10-yr
  11  Rainfall=3.14"
  10
  Runoff Area=337,194 sf
  Runoff Volume=0.961 af
  9
  Runoff Depth=1.49"
  8
  Flow (cfs)

  Flow Length=391'
  7
  Tc=14.0 min
  6
  CN=82
  5

  4

  3

  2

  1

  0
  0  2 4  6  8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72
  Time (hours)

  Page 186 of 359