E_App E_Post-Development Model  NY-West Seneca 24-hr S1 1-yr Rainfall=1.82"
Prepared by Labella Associates  Printed 4/20/2026
HydroCAD® 10.20-7a s/n 09581 © 2025 HydroCAD Software Solutions LLC  Page 7

  Summary for Subcatchment PS-2:

Runoff  =  3.74 cfs @ 12.04 hrs, Volume=  0.194 af, Depth= 1.40"
  Routed to Pond CH-1 : Chambers

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs
NY-West Seneca 24-hr S1 1-yr Rainfall=1.82"

  Area (sf)  CN  Description
  64,081  98  Paved parking, HSG D
  8,235  80  >75% Grass cover, Good, HSG D
  72,316  96  Weighted Average
  8,235  11.39% Pervious Area
  64,081  88.61% Impervious Area

  Tc Length  Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  6.0  Direct Entry, Direct

  Subcatchment PS-2:
  Hydrograph

  Runoff
  4  3.74 cfs
  NY-West Seneca 24-hr S1 1-yr
  Rainfall=1.82"
  3
  Runoff Area=72,316 sf
  Runoff Volume=0.194 af
  Runoff Depth=1.40"
  Flow (cfs)

  Tc=6.0 min
  2
  CN=96

  1

  0
  0  2 4  6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72
  Time (hours)