Text · page 54 of 359
Read the whole document on one page (all 359 pages, each with its own heading)
599 CONTECH CASCADE CS4 WQU RIM=598.89 WATER SERVICE SYSTEM SC-3500 NE INV=595.00 SA W INV=593.62 RIM=599.00 N INV=593.30 24 NOT FOR CONSTRUCTION NE INV=593.62 E INV=591.15 (100 CHAMBERS) W INV=593.30 599 W INV=595.00 W NEW 4" PVC SDR-21 W INV=591.15 INV=591.25 NEW PRIVATE SA SANITARY LATERAL FIRE HYDRANT MATCH TO SHEET: C301 SA W 300 Pearl Street, Suite 130 FS 600 Buffalo, NY 14202 716-551-6281 SA W C0 SAN CO NEW 6" FIRE SERVICE 600 labellapc.com FS TYP. (AFTER BACKFLOW PREVENTOR) 598 599 598 W 599 DS 599 W W EXP: EXP: W CERTIFICATE OF AUTHORIZATION NUMBER: DS PROFESSIONAL ENGINEERING: 0021272 NEW BACKFLOW PREVENTOR LAND SURVEYING: 0021271 (IN MECHANICAL ROOM) FOR GEOLOGICAL: 0021659 W 598 COMBINED SERVICE. 597 DOMESTIC SERVICE WILL BE 597 598 599 METERED AFTER THE It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 BACKFLOW. NEW BIORETENTION Sec. 7307, for any person, unless acting under the direction of a licensed 600 AREA #2 (± 370 SF) architect, professional engineer, or land surveyor, to alter an item in any W C0 ST-5.2 UD way. If an item bearing the seal of an architect, engineer, or land surveyor 24"x24" CB is altered; the altering architect, engineer, or land surveyor shall affix to 599 UD RIM=597.00 the item their seal and notation "altered by" followed by their signature and 598 UD W INV=592.58 UD date of such alteration, and a specific description of the alteration. 597 UD W 596 UD UD 132 LF 12" UD UD © 2024 2026 LaBella Associates UD UD UD 60 SICPP @ 0.50% UD 596 W 0 ST NEW 6" COMBINED 597 W ST 598 WATER SERVICE STW W W W W W W W W W W W W W HOME LEASING T ST 600 W 75 S CLINTON AVE SUITE 700, ST-5.0 ST ROCHESTER, NEW YORK 14604 4' DIA. MH ST RIM=599.08 S INV=591.30 598 59 ST 9 W E INV=591.92 W INV=591.20 ST 59 597 T D ST 9 ST ST 596 ST 28 LF 12" SICPP 6 ST 59 7 ST W ST @ 1.00% 59 8 ST ST ST-5.1 59 ST ST 9 598 ST ST 220 LF 12" 598 24"x24" CB 59 ST SICPP @ 0.50% 597 RIM=596.00 596 N INV=591.58 W END SECTION 595 UD UD UD UD UD UD INV=589.00 C0 UD UD UD UD UD UD T UD UD UD UD UD 595 W NEW BIORETENTION NEW 6" COMBINED AREA #3 (± 700 SF) WATER SERVICE 9 59 W ST-6.0 596 4' DIA. MH 597 WEST SENECA APARTMENTS T RIM=597.50 598 E INV=590.10 2544 CLINTON ST, 598 599 597 W 596 595 595 W INV=590.00 596 597 WEST SENECA, NY 14224 598 599 ST ST ST ST ST D ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST 175 LF 12" 175 LF 12" W END SECTION ST-6.1 T SICPP @ 1.00% SICPP @ 1.00% INV=5#.## 36"x36" CB RIM=594.35 598 W INV=591.85 W T NO: DATE: DESCRIPTION: CONNECT TO EXISTING 6" W \\cash.lab\P\GLOBAL\Projects\Home Leasing Services\2241067 - Affordable Housing West Seneca\06_Drawings\Civil\C300 UTILITY PLAN.dwg WATERMAIN WITH TS&V Revisions PROJECT NUMBER: 2241067 W DRAWN BY: EMM / SCB REVIEWED BY: SRV / DPB ISSUED FOR: SITE PLAN APPROVAL DATE: 4/20/2026 DRAWING NAME: UTILITY PLAN DRAWING NUMBER: UTILITY PLAN NOTES: 4/20/2026 1:17:32 PM 1. A MINIMUM OF 10 FEET OF HORIZONTAL AND 18" OF VERTICAL SEPARATION N MUST BE MAINTAINED BETWEEN ALL SANITARY AND WATER SERVICES 1 UTILITY PLAN 0' 20' 40' 60' 2. THE ERIE COUNTY WATER AUTHORITY IS TO BE NOTIFIED A MINIMUM OF C302 48-HOURS PRIOR TO STARTING THE CONNECTION TO THE NEW WATER SERVICE C302 SCALE: 1" = 20' 3. SELECT BACKFILL IS REQUIRED FOR ALL UTILITIES (GAS, WATER, STORM, SANITARY) THAT CROSS THROUGH ANY PAVEMENT AREA Page 54 of 359