GENERAL NOTES  CONTRACTOR

  GROUNDING NOTES
SITE NOTES  2.5.1 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED  INTERCONNECTION NOTES
  2.7.1 LOAD SIDE INTERCONNECTION SHALL BE IN
  |_JEMPIRESOLAR
2.1.1  ALADDER WILL BE IN PLACE FOR INSPECTION IN ACCORDANCE  FOR THEIR PURPOSE, AND GROUNDING DEVICES EXPOSED TO
WITH OSHA REGULATIONS.  THE ELEMENTS SHALL BE RATED FOR SUCH USE.  ACCORDANCE WITH NEC 705.
2.1.2 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND  2.7.2 THE SUM OF THE UTILITY OCPD AND INVERTER
  2.5.2 PV EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE  EMPIRE SOLAR SOLUTIONS
THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH STORAGE  CONTINUOUS OUTPUT MAY NOT EXCEED 120 PERCENT OF
  WITH NEC 690 AND NEC TABLE 250.122.
BATTERIES.  BUSBAR RATING PER NEC 705.
  2.5.3 METAL PARTS OF MODULE FRAMES, MODULE RACKING,  2-8 JOHNES ST
2.1.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY  2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)  NEWBURGH, 12550
  AND ENCLOSURES CONSIDERED GROUNDED IN ACCORDANCE
PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.  WITH NEC 250.  OUTPUT CIRCUIT CURRENT AND THE RATING OF THE  PHONE - (845) 728-2165
2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING  2.5.4 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED  OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL  LIC. NO, - WC-29806-H17
AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED IN  IN ACCORDANCE WITH NEC 690 AND INVERTER  NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE
ACCORDANCE WITH SECTION NEC 110.  BUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE
  MANUFACTURER'S INSTALLATION PRACTICES
2.1.5 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND  2.5.5 EACH MODULE WILL BE GROUNDED AS SHOWN IN  LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY
MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED  SOURCE OCPD PER NEC 705.
  MANUFACTURER DOCUMENTATION AND APPROVED BY THE
MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING  AHJ.  2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT
SERVES TO PROTECT THE BUILDING OR STRUCTURE.  2.5.6 THE GROUNDING CONNECTION TO A MODULE SHALL BE  COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT
  ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES  PROTECTION DEVICES SHALL NOT EXCEED AMPACITY OF
EQUIPMENT LOCATIONS  NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER  BUSBAR. HOWEVER, THE MAIN OVERCURRENT PROTECTION
2.2.1 ALL EQUIPMENT SHALL MEET MINIMUM WORKING CLEARANCES IN  MODULE.  DEVICE MAY BE EXCLUDED IN ACCORDANCE WITH NEC 705.
ACCORDANCE WITH NEC 110.  2.5.7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED,  2.7.5 FEEDER TAP INTERCONNECTION (LOAD SIDE) IN
2.2.2 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE  SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR  ACCORDANCE WITH NEC 705.
RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY  LARGER PER NEC 250.  2.7.6 SUPPLY SIDE TAP INTERCONNECTION IN ACCORDANCE
2017 NATIONAL ELECTRICAL CODE.  2.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH  WITH TO NEC 705 WITH SERVICE ENTRANCE CONDUCTORS
2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV  NEC 690 AND NEC 250. IF EXISTING SYSTEM IS INACCESSIBLE,  IN ACCORDANCE WITH NEC 230.
  2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWER  PROJECT NAME & ADDRESS
MODULES IN ACCORDANCE WITH NEC 690.  OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM  THOMAS MILLER
2.2.4 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED  PROVIDED IN ACCORDANCE WITH NEC 250, NEC 690 AND THE  SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL
  50 CENTER RIDGE RD,
PERSONNEL IN ACCORDANCE WITH NEC APPLICABLE CODES.  AHJ.  FASTENING PER NEC 705.
  EAST AURORA, NY 14052
2.2.5 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED  2.5.9 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690
FOR OUTDOOR USAGE WHEN APPROPRIATE.  TO REDUCE FIRE HAZARDS
  APN #: 142489A187020000201 7000
STRUCTURAL NOTES  DISCONNECTION AND OVERCURRENT PROTECTION NOTES  AHJ: TOWN OF AURORA
2.3.1 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED IN  UTILITY: NEW YORK STATE
  2.6.1 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT
ACCORDANCE WITH THE CODE-COMPLIANT INSTALLATION MANUAL.  ELECTRIC & GAS
  WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING
TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES,  ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED  SYSTEM DETAILS
AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER  32.190 KW DC-(STC) / 23.000 KW AC
  “LINE SIDE” (TYPICALLY THE UPPER TERMINALS).  (74) HYUNDAI HIN-T435NF(BK)
EDGE OF THE ARRAY/SUB-ARRAY, INACCORDANCE WITH RAIL  2.6.2 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY  (2) TESLA 1707000-XX-Y
MANUFACTURER'S INSTALLATION PRACTICES.  PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH  (29) TESLA MCI-2 RSD'S HIGH CURRENT
2.3.2 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S  2.6.3 PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLE
SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED  BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO
& SEALED PER LOCAL REQUIREMENTS.  REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN  Nae  sa
  REVISIONS
2.3.3 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE
COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER
  ACCORDANCE WITH 690.
  2.6.4 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING
  Wyssling Consulting, PLLC  REV|  DESCRIPTION  DATE
  76 N. Meadowbrook Drive, Alpine UT
CODE BY ALICENSED CONTRACTOR.  TO NEC 690 AND 240.  New York COA #0022571
2.3.4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO  2.6.5 INVERTER ON-GRID BRANCHES SHALL BE CONNECTED TO
GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING  A SINGLE BREAKER OR GROUPED FUSE DISCONNECT(S) IN  Signed 9/10/2025
MANUFACTURER OR PROFESSIONAL ENGINEERING GUIDANCE.  ACCORDANCE WITH NEC 110.  Expires 7/31/2027
  itis a violation of the law for any person, unless
2.3.5 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL  2.6.6 IF REQUIRED BY THE AHJ, SYSTEM WILL INCLUDE
  acting under the direction of a licensed
BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS.  ARC-FAULT CIRCUIT PROTECTION IN ACCORDANCE WITH NEC
  690 AND UL1699B.
  professional, to aiter an item in any way. If an  SHEET TITLE
WIRING & CONDUIT NOTES  item bearing  the seal of a licensed professional
2.4.1 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR  is altered, the altering licensed professional shall  NOTES
THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON  affix to their item their seal and the notation
  “altered by” followed by their signature and the
MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT  DRAWN DATE  9/9/2025
UP-SIZING.  date of such alteration, and a specific
2.4.2 CONDUCTORS SIZED IN ACCORDANCE WITH THE NEC  description of the alteration.  DRAWN BY  VHN
2.4.3 AC CONDUCTORS TO BE COLORED OR MARKED PER NEC
2.4.4 LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USED  SHEET NUMBER
IN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING
OR LABELING PER NEC  PV-05