GENERAL NOTES CONTRACTOR GROUNDING NOTES SITE NOTES 2.5.1 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED INTERCONNECTION NOTES 2.7.1 LOAD SIDE INTERCONNECTION SHALL BE IN |_JEMPIRESOLAR 2.1.1 ALADDER WILL BE IN PLACE FOR INSPECTION IN ACCORDANCE FOR THEIR PURPOSE, AND GROUNDING DEVICES EXPOSED TO WITH OSHA REGULATIONS. THE ELEMENTS SHALL BE RATED FOR SUCH USE. ACCORDANCE WITH NEC 705. 2.1.2 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND 2.7.2 THE SUM OF THE UTILITY OCPD AND INVERTER 2.5.2 PV EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE EMPIRE SOLAR SOLUTIONS THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH STORAGE CONTINUOUS OUTPUT MAY NOT EXCEED 120 PERCENT OF WITH NEC 690 AND NEC TABLE 250.122. BATTERIES. BUSBAR RATING PER NEC 705. 2.5.3 METAL PARTS OF MODULE FRAMES, MODULE RACKING, 2-8 JOHNES ST 2.1.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY 2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) NEWBURGH, 12550 AND ENCLOSURES CONSIDERED GROUNDED IN ACCORDANCE PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. WITH NEC 250. OUTPUT CIRCUIT CURRENT AND THE RATING OF THE PHONE - (845) 728-2165 2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING 2.5.4 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL LIC. NO, - WC-29806-H17 AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED IN IN ACCORDANCE WITH NEC 690 AND INVERTER NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE ACCORDANCE WITH SECTION NEC 110. BUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE MANUFACTURER'S INSTALLATION PRACTICES 2.1.5 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND 2.5.5 EACH MODULE WILL BE GROUNDED AS SHOWN IN LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED SOURCE OCPD PER NEC 705. MANUFACTURER DOCUMENTATION AND APPROVED BY THE MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING AHJ. 2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT SERVES TO PROTECT THE BUILDING OR STRUCTURE. 2.5.6 THE GROUNDING CONNECTION TO A MODULE SHALL BE COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES PROTECTION DEVICES SHALL NOT EXCEED AMPACITY OF EQUIPMENT LOCATIONS NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER BUSBAR. HOWEVER, THE MAIN OVERCURRENT PROTECTION 2.2.1 ALL EQUIPMENT SHALL MEET MINIMUM WORKING CLEARANCES IN MODULE. DEVICE MAY BE EXCLUDED IN ACCORDANCE WITH NEC 705. ACCORDANCE WITH NEC 110. 2.5.7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, 2.7.5 FEEDER TAP INTERCONNECTION (LOAD SIDE) IN 2.2.2 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR ACCORDANCE WITH NEC 705. RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY LARGER PER NEC 250. 2.7.6 SUPPLY SIDE TAP INTERCONNECTION IN ACCORDANCE 2017 NATIONAL ELECTRICAL CODE. 2.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH WITH TO NEC 705 WITH SERVICE ENTRANCE CONDUCTORS 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV NEC 690 AND NEC 250. IF EXISTING SYSTEM IS INACCESSIBLE, IN ACCORDANCE WITH NEC 230. 2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWER PROJECT NAME & ADDRESS MODULES IN ACCORDANCE WITH NEC 690. OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM THOMAS MILLER 2.2.4 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PROVIDED IN ACCORDANCE WITH NEC 250, NEC 690 AND THE SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL 50 CENTER RIDGE RD, PERSONNEL IN ACCORDANCE WITH NEC APPLICABLE CODES. AHJ. FASTENING PER NEC 705. EAST AURORA, NY 14052 2.2.5 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED 2.5.9 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690 FOR OUTDOOR USAGE WHEN APPROPRIATE. TO REDUCE FIRE HAZARDS APN #: 142489A187020000201 7000 STRUCTURAL NOTES DISCONNECTION AND OVERCURRENT PROTECTION NOTES AHJ: TOWN OF AURORA 2.3.1 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED IN UTILITY: NEW YORK STATE 2.6.1 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT ACCORDANCE WITH THE CODE-COMPLIANT INSTALLATION MANUAL. ELECTRIC & GAS WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED SYSTEM DETAILS AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER 32.190 KW DC-(STC) / 23.000 KW AC “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). (74) HYUNDAI HIN-T435NF(BK) EDGE OF THE ARRAY/SUB-ARRAY, INACCORDANCE WITH RAIL 2.6.2 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY (2) TESLA 1707000-XX-Y MANUFACTURER'S INSTALLATION PRACTICES. PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH (29) TESLA MCI-2 RSD'S HIGH CURRENT 2.3.2 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S 2.6.3 PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLE SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO & SEALED PER LOCAL REQUIREMENTS. REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN Nae sa REVISIONS 2.3.3 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER ACCORDANCE WITH 690. 2.6.4 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING Wyssling Consulting, PLLC REV| DESCRIPTION DATE 76 N. Meadowbrook Drive, Alpine UT CODE BY ALICENSED CONTRACTOR. TO NEC 690 AND 240. New York COA #0022571 2.3.4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO 2.6.5 INVERTER ON-GRID BRANCHES SHALL BE CONNECTED TO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING A SINGLE BREAKER OR GROUPED FUSE DISCONNECT(S) IN Signed 9/10/2025 MANUFACTURER OR PROFESSIONAL ENGINEERING GUIDANCE. ACCORDANCE WITH NEC 110. Expires 7/31/2027 itis a violation of the law for any person, unless 2.3.5 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL 2.6.6 IF REQUIRED BY THE AHJ, SYSTEM WILL INCLUDE acting under the direction of a licensed BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. ARC-FAULT CIRCUIT PROTECTION IN ACCORDANCE WITH NEC 690 AND UL1699B. professional, to aiter an item in any way. If an SHEET TITLE WIRING & CONDUIT NOTES item bearing the seal of a licensed professional 2.4.1 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR is altered, the altering licensed professional shall NOTES THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON affix to their item their seal and the notation “altered by” followed by their signature and the MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT DRAWN DATE 9/9/2025 UP-SIZING. date of such alteration, and a specific 2.4.2 CONDUCTORS SIZED IN ACCORDANCE WITH THE NEC description of the alteration. DRAWN BY VHN 2.4.3 AC CONDUCTORS TO BE COLORED OR MARKED PER NEC 2.4.4 LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USED SHEET NUMBER IN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING OR LABELING PER NEC PV-05