Text · page 9 of 11
This document was a scan. Its text was produced by character recognition and may contain errors; check the original for exact wording.
CONTRACTOR |TEMPIRESOLAR EMPIRE SOLAR SOLUTIONS Powerwall 3 Powerwall 3 Technical Specifications Power Everything 2-8 JOHNES ST NEWBURGH, 12550 System Technical Model Number 1707000-xx-y PHONE - (845) 728-2165 Specifications Nominal Grid Voltage (Input & Output) 120/240 VAC LIC. NO, - WC-29806-H17 Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Grid Type Split phase Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to FEM gs 60 He customize system behavior to meat their energy goals. Nominal Battery Energy _ BSRWHACT Nominal Output Power (AC) 5.8 kW 7.6 kW 10 kW 11.5 kW Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing up to 11.5 kW AC of continuous power per Maximum Apparent Power 5,800 VA 7,600 VA 10,000 VA 11,500 VA unit. It has the ability to start heavy loads rated up to 185 LRA, meaning a single unit can support the power needs of most hornes. Powerwall 3 Expansions make it easier and more affordable to scale up customers’ systems to meet their current or Maximum Continuous Current 2A SA ALTA 4BA future needs. Powerwall 3 is designed for fast and efficient installations, modular system expansion, and simple connection to Overcurrent Protection Device? 30A 40A 60A 60A any electrical service. Configurable Maximum Continuous Discharge 15.4 kW Power Off-Grid (PV Only, -20°C to 25°C) Maximum Continuous Charge Current / Power 20.8 A AC /5kW (Powerwall 3 only) Maximum Continuous Charge Current / Power 33.3A AC /8kW (Powerwall 3 with up to (3) Expansion units) Output Power Factor Rating A) -1(Grid Code configurable) Maximum Output Fault Current (1s) 160A PROJECT NAME & ADDRESS Maximum Short-Circuit Current Rating THOMAS MILLER 1OkA 50 CENTER RIDGE RD, Load Start Capability 185 LRA EAST AURORA, NY 14052 Solar to Battery to Home/Grid Efficiency BK" Solar to Home/Grid Efficiency 97.5%§ Power Scalability Up es 4 Pawerwall 3 units supported APN #: 142489A187020000201 7000 AHJ: TOWN OF AURORA Energy Scalability Up to 3 Expansion units (for a maximum total of 7 units) UTILITY: NEW YORK STATE Supported Islanding Devices Gateway 3, Backup Switch, Backup Gateway 2 ELECTRIC & GAS Connectivity SYSTEM DETAILS Hardware Interface Dry contact relay, Rapid Shutdown (RSD) certified switch 32.190 KW DC-(STC) / 23.000 KW AC and 2-pin connector, RS-485 for meters (74) HYUNDAI HIN-T435NF(BK) AC Metering Revenue Grade (+/- 0.5%, ANSI C12.20) (2) TESLA 1707000-XX-Y (29) TESLA MCI-2 RSD'S HIGH CURRENT Protections Integrated arc fault circuit interrupter (AFCI), Isolation Monitor interrupter (IMI), PV Rapid Shutdown (RSD) using Tesla Mid-Circuit interrupters Customer Interface Tesla Mobile App REVISIONS Warranty 10 years Values provided for 25°C (77°F), at beginning of life. 3.3 kW charge/discharge power. REV} DESCRIPTION DATE 2See Powerwall 3 Installation Manual for fuse requirements if using fuse for overcurrent protection. 315.4kW off-grid maximum continuous discharge power is only available if on-grid rating is 11.5 kW. If enabled, Powerwall 3 must be installed with an 80 A breaker and appropriately sized conductors. ‘Typical solar shifting use case. 5Tested using CEC weighted efficiency methodology. ’The customer Is expected to provide internet connectivity for Powerwall 3; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. SHEET TITLE RESOURCE DOCUMENTS 2025 2025 Poworwali 3 Datashest DRAWN DATE 9/9/2025 DRAWN BY VHN SHEET NUMBER R-02