Text · page 365 of 849
Read the whole document on one page (all 849 pages, each with its own heading)
© 2023 Crafted Concepts Architecture P.C. All rights reserved. No part of this document may be reproduced or utilized in any form, without prior written authorization by Crafted Concepts Architecture P.C. GENERAL CONSTRUCTION NOTES 1 2 3 4 5 4 1. ALL CONSTRUCTION IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND THE REQUIREMENTS OF ALL REGULATORY AGENCIES HAVING JURISDICTION OVER THE PROJECT. UNDER NO CONDITION DOES THE ARCHITECT HAVE RESPONSIBILITY FOR THE MEANS OR METHODS USED BY THE CONTRACTOR IN THE PERFORMANCE OF THE WORK OR FOR CONDITIONS OF SAFETY AT THE JOB SITE. 2. THE CONTRACTOR IS RESPONSIBLE FOR THE PAYMENT FOR AND THE ACQUISITION OF ALL REQUIRED PERMITS AND FEES ASSOCIATED WITH THE PROJECT. A 3. THE CONTRACTOR SHALL CONFIRM THE LOCATION OF ALL EXISTING UTILITIES AND COORDINATE THE INSTALLATION OF ALL NEW UTILITIES AND METER LOCATIONS WITH THE UTILITY COMPANY OR GOVERNMENTAL AUTHORITY HAVING JURISDICTION OVER THE PROJECT. 4. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO THOROUGHLY REVIEW AND BECOME FAMILIAR WITH ALL PERTINENT DOCUMENTS AVAILABLE REGARDING THE CONSTRUCTION OF THIS PROJECT. ANY AMBIGUITY OR DISCREPANCY DISCOVERED IN THE DOCUMENTS SHALL BE IMMEDIATELY MANDATORY CLEARANCE REPORTED TO THE ARCHITECT WHO SHALL MAKE CLARIFICATIONS AND INTERPRETATIONS IN A 2 TIMELY MANNER. THE CONTRACTOR'S FAILURE TO DISCOVER AND NOTIFY THE ARCHITECT OF SAID 101A AMBIGUITY OR DISCREPANCY PRIOR TO THE START OF CONSTRUCTION SHALL NOT RELIEVE THE INFILL DOOR EX101 OPENING IN KIND GOLF CONTRACTOR OF RESPONSIBILITY RELATING TO THE MATTER. WITH ADJACENT SIMULATOR 5. CHANGES, OR DEVIATIONS FROM THE DOCUMENTS, MADE BY THE CONTRACTOR OR THEIR WALL ENTRY SUPPLIERS, WITHOUTTHE WRITTEN CONSENT OF THE ARCHITECT, ARE UNAUTHORIZED CHANGES 103 TO THE WORK AND AS SUCH SHALL RELIEVE THE ARCHITECT OF ALL RESPONSIBILITY FOR THE 101 CONSEQUENCES ARISING THEREFROM. 6. PRIOR TO THE BEGINNING ANY NEW WORK OR INSTALLATION, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT PREVIOUSLY INSTALLED WORK AND/OR SUBSTRATE AND VERIFY THAT ALL WORK IS SATISFACTORY AND COMPLETE TO THE REQUIRED LEVEL OF ACCEPTANCE TO ALLOW FOR THE START OF SUBSEQUENT WORK. THE COMMENCEMENT OF ANY WORK SHALL INDICATE THAT ALL PREVIOUSLY INSTALLED WORK AND/OR SUBSTRATE WAS FOUND TO BE ACCEPTABLE AND INSTALLED ACCORDING TO INDUSTRY STANDARDS. ANY WORK FOUND TO BE IN UNACCEPTABLE CONDITION SHALL BE REMOVED AND REPLACED AT NO ADDITIONAL COST TO THE OWNER. 7. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO ESTIMATING THE COST OF THE SCOPE BACK BAR OF WORK AND PRIOR TO ORDERING OR FABRICATING MATERIALS OR BEGINNING ANY EX107 4' - 1 1/4" 4' - 6" CONSTRUCTION RELATED ACTIVITIES FOR THE PURPOSE OF BECOMING COMPLETELY FAMILIAR THE 102 SITE AND ALL EXISTING CONDITIONS WHICH MIGHT IMPACT THE COST OF, OR PERFORMANCE OF THE B SCOPE OF WORK. ADA COUNTER, 34" MAX. 8. IF AT ANY TIME HAZARDOUS WASTE IS ENCOUNTERED IT SHALL BE REMOVED AND DISPOSED OF AS HEIGHT - OVER 5% OF REQUIRED BY THE AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. THE ARCHITECT AND HALL TOTAL COUNTER GENERAL CONTRACTOR IS NOT KNOWLEDGEABLE OF THE EXISTENCE OF HAZARDOUS WASTE AND 105 SHALL NOT BE HELD RESPONSIBLE FOR THE REMOVAL OF HAZARDOUS WASTE. EX106 9. THE CONTRACTOR(S) SHALL KEEP PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS EX105 AND DEBRIS. 108A 10. ALL DIMENSIONS OF NEW WALLS ARE TO FACE THE WALL UNLESS OTHERWISE NOTED ON DRAWING. 11. DO NOT SCALE THE DRAWINGS, IF QUESTIONS ARISE AS TO DIMENSIONAL REQUIREMENTS, C CONTACT THE ARCHITECT FOR CLARIFICATION. 12. FRAME DOOR OPENINGS SUCH THAT EACH ROUGH OPENING JAMB IS A MINIMUM OF 4 1/2" INCHES TO THE NEAREST INSIDE CORNER UNLESS OTHERWISE NOTED, TO ALLOW FOR FULL CASING AND TRIM. MANDATORY CLEARANCE MANDATORY CLEARANCE 13. ALL DOORS THAT DO NOT HAVE LABELS ARE EXISTING DOORS THAT SHOULD BE EXAMINED FOR 18' - 1 1/2" EX109 STORAGE POSSIBLE REUSE. 109 6' - 2 1/2" GOLF GOLF SIMULATOR SIMULATOR 101B 3 106 107 STRUCTURAL 4 1/2" 6 1/2" COLUMN AND KITCHEN / BAR 14' - 6" FOOTER, SEE A100 PREP 1/2" 3 1/2" 1/2" 1/2" 5 1/2" 1/2" A 108 UTILITY SINK DESIGNED 1/2" GWB (BOTH 1/2" GWB (BOTH D CABINET STRUCTURAL COLUMN AND BY OTHERS SIDES) USE MR NOTE: SIDES) USE MR NOTE: GWB IN WET 5/8" GWB TO BE GWB IN WET 5/8" GWB TO BE FOOTER, SEE A100 LOCATIONS USED FOR MORE LOCATIONS USED FOR MORE INTERIOR PARTITIONS UNISEX UNISEX DURABLE WALL DURABLE WALL 25' - 0" A 2x4 WOOD 2x6 WOOD FRAMING CONSTRUCTION FRAMING CONSTRUCTION 110 111 4' - 0" 2' - 0" PER OWNER OR PER OWNER OR SOUND CONTRACTOR SOUND CONTRACTOR DAMPENING PREFERENCE DAMPENING PREFERENCE INSULATION AT INSULATION 110A 111A +/- 27' - 0" BEDROOMS AND BATH UP E HALL STAIR INTERIOR WOOD STUD & DRYWALL INTERIOR DRYWALL PARTITION HALL A PARTITION WITH INSULATION B 113 112 A 120 3 5 7/8" 7 7/8" A 5/8" 1/2" 5/8" 1/2" 113A 112B 112A 5/8" 3 1/2" 5/8" 5/8" 5 1/2" 5/8" 4' - 0" MIN. ACCESSIBLE COUNTER, 34" (2) 5/8" GWB 1/2" (2) 5/8" GWB 1/2" 116A MAX. HEIGHT - OVER 5% OF SIMULATOR COUNTERS SPRINKLER USE MR GWB IN RESILIENT USE MR GWB IN RESILIENT WET CHANNELS WET CHANNELS ELEV. RISER ROOM LOCATIONS LOCATIONS 06 AUG 2025 24 APR 2026 08 JAN 2026 30 JUL 2025 115 114 EX114 2x4 WOOD 2x4 WOOD FRAMING FRAMING Date SOUND 5/8" GWB, USE SOUND 5/8" GWB, USE DAMPENING MR GWB IN WET DAMPENING MR GWB IN WET INSULATION LOCATIONS INSULATION LOCATIONS BUILDING PERMIT SUBMISSION STRUCTURAL AND CEILING STRUCTURAL UPDATE COAT ADDITION OF GOLF 119 INTERIOR DRYWALL PARTITION INTERIOR DRYWALL PARTITION 1HR C D E STRUCTURAL UL U305 1 HOUR FIRE RATING - STC 50+ UL U305 1 HOUR FIRE RATING - STC 50 1HR SIMULATORS COLUMN AND ADDITIONAL MECH. REVISIONS 4 1/2" Description +/- 24' - 6" FOOTER, SEE A100 SEATING 121 RECREATION HALL 117 1/2" 3 1/2" 1/2" 233 118 EXTERIOR PATIO 116 1/2" GWB (BOTH +/- 18' - 8" SIDES) USE MR NOTE: Rev. GWB IN WET 5/8" GWB TO BE 4 3 2 1 EXISTING WALL LOCATIONS USED FOR MORE IN MECH. ROOM 2x4 WOOD DURABLE WALL AND SLOPED FRAMING CONSTRUCTION E WALL BELOW PER OWNER OR STAIR TO EX122 SOUND CONTRACTOR REMAIN MECH. DAMPENING PREFERENCE WEST SENECA, NEW YORK 14224 INSULATION AT 122 BEDROOMS 5700 SENECA AND BATH F 5700 SENECA STREET EX118 EX116 3 INTERIOR WOOD STUD & DRYWALL E PARTITION WITH INSULATION 1HR UL U305 1 HOUR FIRE RATING - STC 48 G 2 3 A300 A101 5/12/2026 5:35:22 PM 1 GROUND FLOOR PLAN A101 1/4" = 1'-0" FIRST FLOOR PLAN Page 365 of 849