Southtowns Record

PBA06.11.2026packet

Government
Town of West Seneca
Board
Planning Board
Meeting
Jun 11, 2026, 6:00 p.m.
Posted by publisher
Jun 3, 2026
Kind
Agenda packet
Topics
Water, sewer and drainage, Housing, Zoning and land use, Roads and traffic, Parks and recreation, Budget and taxes, Public safety

Original document

Same meeting

Text · page 455 of 849

Read the whole document on one page (all 849 pages, each with its own heading)

sections 7209N and 7301 of the New York State Education Law for any person, unless acting under the direction of a registered architect, licensed engineer or land surveyor
to alter this drawing. If altered such R.A., P.E. or L.L.S. shall affix his or her seal, signature, the date,the notation "Altered By" and a specific description of the alteration.
All Rights Reserved. Reuse of these documents without the expressed written permission of CARMINAWOOD DESIGN is prohibited. WARNING it is a violation of article 145

  Greensboro
  UE

  G
  UE
  EX. PIN  CB

  W
  RIM:683.34

  Utica
  APPROX. LOCATION

  G
  N. INV:672.94 (18")

  ST
  UE
  S. INV:673.10 (18")

  OE

  SA
  CB

  W

  Buffalo
  2"  RIM:680.53

  G
  3
  8'-

  UE
  N. INV:671.23 (18")

  EX 5A' N .
  CB
  °-5

  OE

  ST W

  5.2 S 2' E OE
  0  S. INV:671.23 (18")

  .N .
  0  RIM:685.39

  0.3G
  1

  AI
  C.O.  N. INV:677.49 (18")

  L
  UE
  CONNECT DOWNSPOUTS TO 6" HDPE PERIMETER  87°-09'-45"  S. INV:677.49 (16")
  UE

  DRAIN @ 1.0%. COORDINATE DOWNSPOUT  YD 4  E. INV:676.99 (4")

  W
  LOCATIONS WITH ARCHITECTURAL PLANS.

  STG
  RIM 680.20

  OR
  INV 678.70
  UE

  UE

  SA
  OT  MH

  OE
  L
  IT.  RIM:685.89

  W
  CB 6  C.O.  B
  NW. INV:676.14 (12")

  CH
  G
  RIM 679.00

  UE
  INV 676.80  SE. INV:676.22 (12")

  SA

  Multifamily Development
  1 .0
  130 LF 6"

  W
  PP .

  OE

  AR
  HDPE @ 0.5%

  G
  CB 1

  'E
  CONNECT DOWNSPOUTS TO 6" HDPE PERIMETER

  UE
  RIM 683.25

  ST
  DRAIN @ 1.0%. COORDINATE DOWNSPOUT
  EX. REBAR

  BU
  PRO ING .F.E.
  LOCATIONS WITH ARCHITECTURAL PLANS.  INV 681.00

  ILD F
  126 LF 8"

  PO W/A = 68
  4.11' N.

  W
  HDPE @ 0.5%

  SED TT 1.6

  OE

  D
  SA
  C.O.  C.O.

  G
  UE
  1-S ACH 0
  100 LF 8"

  TO ED
  HDPE @ 0.7%  C.O.

  RY GA

  PA
  5-U RAG

  W
  NIT ES
  113°-18'-53"

  OE
  CB 7

  UE

  G
  RIM 678.80

  SA
  INV 676.30

  RK
  C.O.  C.O.  YD 5  CONNECT DOWNSPOUTS TO 6" HDPE PERIMETER

  SWT
  OE
  RIM 680.20  DRAIN @ 1.0%. COORDINATE DOWNSPOUT

  UE

  1425 & 1475 Orchard Park Rd
  INV 678.05

  G
  CB 2  LOCATIONS WITH ARCHITECTURAL PLANS.

  BUILDING W/ATTACHED GARAGES
  51 LF 12"  32 LF 6" HDPE ROOF
  EX.  PIN  RIM 683.25

  PROPOSED 1-STORY 4-UNIT
  HDPE @ 0.5%  LEADER @ 1.0%  C.O.  INV 680.30 NE

  RO
  82 LF 12"

  SA GS
  F.F.E. = 681.15
  CONNECT DOWNSPOUTS TO 6" HDPE PERIMETER  INV 677.97 SW  IT S

  OE

  PP 8' E.
  UN RAGE

  W
  HDPE @ 0.3%  CB 5

  UE
  DRAIN @ 1.0%. COORDINATE DOWNSPOUT  52 LF 6"  4  C.O.

  0.
  RIM 679.80  Y -  A
  LOCATIONS WITH ARCHITECTURAL PLANS.  YD 7  HDPE @ 0.5%  T OR ED G

  T
  RIM 680.00  INV 676.17  32 LF 6" HDPE ROOF  S
  1- CH 0
  BUILDING W/ATTACHED GARAGES

  S ED ATTA 84.8  YD 1

  AD
  INV 675.92  LEADER @ 1.0%  O  6
  OP W/ =
  PROPOSED 1-STORY 4-UNIT

  RIM 683.70
  PR ING .F.E.
  © CARMINA WOOD DESIGN

  OE
  YD 6

  W

  EX 9' N
  INV 681.98

  UE
  RIM 680.20  ILD F

  SA

  West Seneca, NY
  5.8 /L W G
  BU

  G
  F.F.E. = 680.40

  C.O.  C.O.

  .R .
  INV 677.28  12"x6" TEE

  ±OST E
  CB 8

  EB
  RIM 678.80
  STOP  INV 677.79

  (6
  INV 676.05

  AR
  O
  UE
  30 LF 6" HDPE ROOF  17 LF 6" HDPE ROOF  66 LF 6"
  LEADER @ 1.0%  132 LF 12"  LEADER @ 1.0%  HDPE @ 0.5%

  6.0
  HDPE @ 0.7%

  SA
  46 LF 6"
  HDPE @ 0.5%  149 LF 8"  YD 2

  UE

  ST
  71 LF 12"  HDPE @ 0.8%  RIM 683.70
  HDPE @ 0.5%

  W
  C.O.  C.O.  INV 681.65

  ')
  CB 3

  OE
  OE
  32 LF 6" HDPE ROOF  RIM 682.15  PP

  G
  63 LF 12"  70 LF 8"  OE
  LEADER @ 1.0%  INV 679.90 E  C.O.  OE
  OE  PP
  HDPE @ 0.5%  HDPE @O0.8%
  E  1.0' E.

  SA
  UE
  148 LF 12"  INV 677.05 NE, NW, W  OE
  32 LF 6" HDPE ROOF  OE
  OE  EX. IP.

  11
  HDPE @ 1.0%  OE  YD 3
  LEADER @ 1.0%

  WST
  BIORETENTION AREA #1  OE

  OE
  RIM 684.00

  5°
  2,855 S.F.  CB 4  PP  7.27' NW.

  OE
  INV 681.09

  -0
  G
  (2,850 S.F. REQUIRED)  RIM 679.90

  Date
  4'- SA
  C.O.  C.O.  PARKING
  TOP ELEV = 673.50  INV 675.57

  47
  YD 12-15 (TYP.)
  RIM 673.50
  BOTTOM ELEV = 673.00  STOP  LOT

  "
  W
  30 LF 6" PERF.  131 LF 12"

  OE
  OE
  INV 669.67  HDPE @ 0.0%  121 LF 12"  STM MH 1  HDPE @ 1.0%

  G
  HDPE @ 1.0%  RIM 679.20

  ST
  31 LF 6"  INV 675.74 N  12"  W
  A
  48 LF 6" HDPE ROOF  INV 674.21 SW, E
  RE

  OE
  HDPE @ 0.3%  EX. PIPE TO DISCHARGE
  .A

  OE

  W
  LEADER @ 1.0%  DIRECTLY TO CB 12
  BIT

  SA
  12"  170°-37'-13"

  OE
  HYD

  ST G E
  APPROX. LOCATION  CB 12

  No. Description
  12"x6" TEE  CONTRACTOR TO VERIFY LIMITS OF

  O

  W
  INV 673.58  OF CEMETERY  CEMETERY AND NOTIFY DESIGN  RIM 682.90
  INV 679.28

  REVISIONS:
  END SECTION  ENGINEER OF ANY POTENTIAL CONFLICTS
  INV 673.00
  HEAD STONES NOT

  SA
  673  LOCATED  127°-49'-44"

  G
  OE

  W
  673  YD 16-18 (TYP.)

  ST
  RIM 673.50  14"
  INV 669.67  28"
  14"
  END SECTION  EX. IP.
  INV 673.00  W. INV: 682.97
  355 LF 12" HDPE @ 1.0%
  EX. STORM SEWER TO BE  (12" HDPE)
  12" E-W INV 675.41
  48 LF 12"  12" NW-SE INV 673.40  RE-ROUTED.
  END SECTION
  INV 669.57  HDPE @ 1.1%  73 LF 12" HDPE @ 1.0%
  EX. STORM SEWER TO BE
  31 LF 6"  RE-ROUTED.
  HDPE @ 0.3%
  TOP OF  CB 10  STM MH 2
  POND 675.30  BIORETENTION AREA #2  END SECTION  PARKING
  1,700 S.F.  CB 11  12"x6" TEE  123 LF 12"  RIM 679.50  RIM 683.00
  INV 675.00  RIM 678.00  INV 675.98  HDPE @ 1.1%  INV 676.83  INV 678.55
  (1,620 S.F. REQUIRED)
  INV 675.48 E
  LOT
  TOP ELEV = 673.50
  BOTTOM ELEV = 673.00  INV 673.53 NW

  STORMWATER RUNOFF SUMMARY

  Drainage Plan - North  TO DETENTION:
  PROPOSED UTILITY LEGEND
  PROPOSED STORM SEWER  ST
  SCALE: 1"=30'  EVENT  PROP. RUNOFF (CFS) ELEVATION (FEET)  STORAGE (CF)
  1-YEAR  1.94  671.04  5,335
  10-YEAR  2.82  672.95  15,013  PROPOSED SANITARY SEWER  6" SA  DRAWING NAME:
  25-YEAR  3.10  673.70  21,268
  100-YEAR  3.45  674.73  34,966  Drainage
  PROPOSED WATERLINE  1" W
  DIRECT:  Plan - North
  EVENT  PROP. RUNOFF (CFS)  PROPOSED CATCH BASIN  CB
  1-YEAR  0.38
  10-YEAR  1.12
  25-YEAR  1.57  PROPOSED YARD DRAIN  YD
  100-YEAR  2.52  Date:  5/22/26
  Drawn By:  A. Pandolfe
  TOTAL SITE:  PROPOSED MANHOLE  MH  Scale:  As Noted
  EVENT  EX. RUNOFF (CFS)  PROP. RUNOFF (CFS)  DRAWING NO.
  1-YEAR  2.63  2.32  PROPOSED HYDRANT ASSEMBLY
  10-YEAR  8.17  3.94
  25-YEAR
  100-YEAR
  11.66
  18.97
  4.67
  5.97  PROPOSED GATE VALVE
  NOTE: FOR PROPOSED VALVE BOXES, CLEANOUTS, ETC., INSTALL A
  3,000 PSI CONCRETE COLLAR AROUND THE ITEM AT GRADE. THE
  GV  NOTE: BOUNDARY AND TOPOGRAPHIC INFORMATION PROVIDED BY OTHERS,
  CARMINA WOOD DESIGN ASSUMES NO RESPONSIBILITY FOR ITS ACCURACY.

  30  0  30  60Ft.
  C-301
  Project No:  23-4121
  COLLAR SHALL BE A MINIMUM OF 6" WIDER, ON ALL SIDES, THAN THE  30'
  BOX, CLEANOUT, ETC. THE COLLAR SHALL BE A MINIMUM OF 6" THICK.
  Page 455 of 849