23-4121 storm calcs - Existing  Type II 24-hr 10-Year Rainfall=3.14"
Prepared by Carmina Wood Design  Printed 5/14/2026
HydroCAD® 10.20-8a s/n 05019 © 2025 HydroCAD Software Solutions LLC  Page 11

  Summary for Subcatchment 2S: Existing - South

Runoff  =  3.19 cfs @ 12.13 hrs, Volume=  10,615 cf, Depth= 1.36"
  Routed to nonexistent node 6L

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.50-70.02 hrs, dt= 0.04 hrs
Type II 24-hr 10-Year Rainfall=3.14"

  Area (sf)  CN  Description
  93,939  80  Pasture/grassland/range, Good, HSG D
  93,939  100.00% Pervious Area

  Tc Length Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  17.5  150 0.0370  0.14  Sheet Flow,
  Grass: Dense n= 0.240 P2= 2.50"
  2.6  212 0.0370  1.35  Shallow Concentrated Flow,
  Short Grass Pasture Kv= 7.0 fps
  20.1  362 Total

  Subcatchment 2S: Existing - South
  Hydrograph

  Runoff
  3.19 cfs

  3
  Type II 24-hr
  10-Year Rainfall=3.14"
  Runoff Area=93,939 sf
  Runoff Volume=10,615 cf
  Flow (cfs)

  2
  Runoff Depth=1.36"
  Flow Length=362'
  Slope=0.0370 '/'
  1  Tc=20.1 min
  CN=80

  0
  5  10  15  20  25  30  35  40  45  50  55  60  65  70
  Time (hours)

  Page 516 of 849