23-4121 storm calcs - Existing  Type II 24-hr 25-Year Rainfall=3.84"
Prepared by Carmina Wood Design  Printed 5/14/2026
HydroCAD® 10.20-8a s/n 05019 © 2025 HydroCAD Software Solutions LLC  Page 12

  Time span=0.50-70.00 hrs, dt=0.04 hrs, 1739 points
  Runoff by SCS TR-20 method, UH=SCS, Weighted-CN
  Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method

Subcatchment 1S: Existing - North  Runoff Area=181,234 sf 0.00% Impervious Runoff Depth=1.91"
  Flow Length=806' Tc=28.2 min CN=80 Runoff=7.12 cfs 28,850 cf

Subcatchment 2S: Existing - South  Runoff Area=93,939 sf 0.00% Impervious Runoff Depth=1.91"
  Flow Length=362' Slope=0.0370 '/' Tc=20.1 min CN=80 Runoff=4.54 cfs 14,954 cf

  Total Runoff Area = 275,173 sf Runoff Volume = 43,803 cf Average Runoff Depth = 1.91"
  100.00% Pervious = 275,173 sf 0.00% Impervious = 0 sf