23-4121 storm calcs - Existing  Type II 24-hr 25-Year Rainfall=3.84"
Prepared by Carmina Wood Design  Printed 5/14/2026
HydroCAD® 10.20-8a s/n 05019 © 2025 HydroCAD Software Solutions LLC  Page 13

  Summary for Subcatchment 1S: Existing - North

Runoff  =  7.12 cfs @ 12.23 hrs, Volume=  28,850 cf, Depth= 1.91"
  Routed to nonexistent node 6L

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.50-70.02 hrs, dt= 0.04 hrs
Type II 24-hr 25-Year Rainfall=3.84"

  Area (sf)  CN  Description
  131,812  80  Pasture/grassland/range, Good, HSG D
  49,422  79  Woods/grass comb., Good, HSG D
  181,234  80  Weighted Average
  181,234  100.00% Pervious Area

  Tc Length Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  16.9  150 0.0400  0.15  Sheet Flow,
  Grass: Dense n= 0.240 P2= 2.50"
  5.2  287 0.0170  0.91  Shallow Concentrated Flow,
  Short Grass Pasture Kv= 7.0 fps
  4.0  284 0.0280  1.17  Shallow Concentrated Flow,
  Short Grass Pasture Kv= 7.0 fps
  2.1  85 0.0180  0.67  Shallow Concentrated Flow,
  Woodland Kv= 5.0 fps
  28.2  806 Total

  Subcatchment 1S: Existing - North
  Hydrograph

  Runoff
  7.12 cfs
  7  Type II 24-hr
  25-Year Rainfall=3.84"
  6
  Runoff Area=181,234 sf
  5  Runoff Volume=28,850 cf
  Flow (cfs)

  Runoff Depth=1.91"
  4
  Flow Length=806'
  3  Tc=28.2 min
  CN=80
  2

  1

  0
  5  10  15  20  25  30  35  40  45  50  55  60  65  70
  Time (hours)

  Page 518 of 849