Part IV.B.1.
  implemented within the active work area daily to ensure that they are being
  maintained in effective operating condition at all times. If deficiencies are
  identified, the contractor must:

  a. if the corrective action does not require engineering design:

  i. begin implementing corrective actions within one business day; and

  ii. complete the corrective actions within five business days; or

  b. if the corrective action requires engineering design:

  i. begin the engineering design process within five business days;
  and

  ii. complete the corrective action in a reasonable time frame but no
  later than within 60 calendar days.

  2. For construction sites where soil disturbance activities have been temporarily
  suspended (e.g. winter shutdown) and temporary stabilization measures have
  been applied to all disturbed areas, the trained contractor can stop conducting
  the maintenance inspections in accordance with Part IV.B.1. The trained
  contractor must begin conducting the maintenance inspections in accordance
  with Part IV.B.1. as soon as soil disturbance activities resume.

  3. For construction sites where soil disturbance activities have been shut down
  with partial project completion, the trained contractor can stop conducting the
  maintenance inspections in accordance with Part IV.B.1. if all areas disturbed
  as of the project shutdown date have achieved final stabilization and all SMPs
  required for the completed portion of the project have been constructed in
  conformance with the SWPPP and are operational.

C. Qualified Inspector Inspection Requirements

  1. With the exception of the following construction activities identified in Tables 1
  and 2 of Appendix B, a qualified inspector must conduct site inspections for
  all other construction activities identified in Tables 1 and 2 of Appendix B:

  a. the construction of a single-family residential subdivision with 25% or less
  impervious cover at total site build-out that involves a soil disturbance of
  one (1) or more acres of land but less than or equal to five (5) acres and is

  38