Text · page 1151 of 1493
Read the whole document on one page (all 1493 pages, each with its own heading)
6' sections 7209N and 7301 of the New York State Education Law for any person, unless acting under the direction of a registered architect, licensed engineer or land surveyor to alter this drawing. If altered such R.A., P.E. or L.L.S. shall affix his or her seal, signature, the date,the notation "Altered By" and a specific description of the alteration. All Rights Reserved. Reuse of these documents without the expressed written permission of CARMINAWOOD DESIGN is prohibited. WARNING it is a violation of article 145 Greensboro 2' DETECTABLE TAPE, 1'-6" TRENCH WIDTH BELOW FINISHED GRADE WIDTH OF PIPE (I.D. + 24") 2 Utica 2' 12" (I.D.) 12" Buffalo 12" 1 . PLAN VIEW O.D. IA .) D D (I. (6"MIN.) 1/3 I.D. (12"MAX.) NOTES: A. PIPE INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. Multifamily Development B. TRENCHING OPERATIONS SHALL INCLUDE ALL NECESSARY DEWATERING. 6'-0" C. TRENCH DETAILS ARE ONLY SHOWN FOR PURPOSES OF MATERIAL PLACEMENT AND MAXIMUM PAY LIMITS. D. AN OSHA APPROVED MOVABLE PROTECTIVE TRENCH SHIELD SHALL BE USED IN ALL UNSHEETED TRENCH AREAS. TYPICAL PRECAST CATCH BASIN MATERIALS ELEVATION PIPE BEDDING MATERIAL (NYSDOT 1985 EDITION) 1 NO. 1 CRUSHED STONE OR CRUSHED GRAVEL WITH A GRADATION CONFORMING WITH NYSDOT SECTION 703-02. THE MATERIAL SHALL BE WELL GRADED WITH NO PARTICLES LARGER THAN ONE INCH AND HAVING A MAXIMUM GRADATION MEETING THE LIMITS DESCRIBED IN THE GRADE TYPICAL PIPE OUTLET W/END SECTION & RIP RAP SPECIFICATIONS. THE BEDDING SHALL BE COMPACTED IN 6" LIFTS WITH EQUIPMENT ACCEPTABLE TO THE PIPE MANUFACTURER. 1425 & 1475 Orchard Park Rd NO SLAG SHALL BE ALLOWED FOR MATERIAL 1 8" DIA. INLINE YARD DRAIN WITH "STANDARD" GRATE 2 TYPE 2 CRUSHED STONE OR CRUSHED GRAVEL WITH A GRADATION CONFORMING WITH NYSDOT 6" SECTION 304-2.02 TYPE 2. THE MATERAIL SHALL BE WELL GRADED WITH NO PARTICLES LARGER THAN TWO INCHES AND HAVING A MAXIMUM GRADATION MEETING THE LIMITS DESCRIBED IN THE SPECIFICATIONS. THE BEDDING SHALL BE COMPACTED IN 6" LIFTS WITH EQUIPMENT © CARMINA WOOD DESIGN ACCEPTABLE TO THE PIPE MANUFACTURER. HYDROSEED West Seneca, NY 3H NO SLAG SHALL BE ALLOWED FOR MATERIAL 2 YARD DRAINS SHALL BE 1V NOTES: NYLOPLAST AMERICA INC. OR APPROVED EQUAL MAX. PONDING/ OVERFLOW ELEV. 1. FILTER FABRIC TO BE NON-WOVEN CLASS 'C', MIRAFI 180-N OR RIM OF YD 6" PONDING HEIGHT EL. 673.50 APPROVED EQUIVALENT EL. 673.00 2. DRAINAGE GRAVEL TO MEET AASHTO M-43. NO.67, SIZE 0.25" TO 0.75" STORM SEWER TRENCH SECTION 3. CONTRACTOR TO PROVIDE PLANTING SOIL SUBMITTAL SPECIFICATION FOR REVIEW AND APPROVAL PRIOR TO HDPE RISER PIPE IN PAVED AREAS CONSTRUCTION. 4. BIORETENTION SOIL IS NOT TO BE INSTALLED UNTIL SITE IS STABILIZED. 30" MIN. PLANTING SOIL DEPTH PLANTING SOIL BED NOTE:PLANTING SOIL SHALL BE LOAM/SAND MIX CONTAINING A MINIMUM OF 35 TO 60% SAND BY VOLUME AND LESS THAN 25% CLAY. SOIL SHOULD FALL WITHIN USCS TYPES SM OR ML WITH PERMEABILITY OF AT LEAST 1.0 FEET PER DAY. SOIL SHOULD BE FREE FROM STONES, 6/15/26 STUMPS, ROOTS OR OTHER WOODY MATERIAL OVER 1" IN DIAMETER. Date 6" PERFORATED HDPE PLACEMENT OF THE PLANTING SOIL SHOULD BE IN LIFTS OF 12" TO UNDERDRAIN IN 10" EL. 670.50 18", LOOSELY COMPACTED. 6" TOPSOIL (MIN.) 90° HDPE ELBOW DRAINAGE GRAVEL JACKET EL. 669.67 CHARACTERISTICS SHALL BE: PH RANGE: 5.2 - 7.00 NOTE: ORGANIC MATTER: 1.5 - 4.0% FILTER FABRIC Per Engineering comments FOR INLINE DRAINS, THE ELBOW SHALL 6" PHDPE SUBGRADE OR EX. MAGNESIUM: 35 LBS PER ACRE MIN. BE REPLACED BY A TEE SOIL PHOSPHORUS: 75 LBS PER ACRE MIN. UNDERDRAIN DRAINAGE GRAVEL EXCAVATED FROM TRENCH POTASSIUM: 85 LBS PER ACRE MIN. BACKFILL WITH MATERIAL DETECTABLE TAPE, 1'-6" BELOW FINISHED GRADE PIPE @ 0.0% SOLUBLE SALTS: 500 PPM TRENCH WIDTH HDPE PIPE, SEE PLAN FOR SIZE & SLOPE CLAY: 10 TO 25% (I.D. + 24") SILT: 30 TO 55% BIORETENTION AREA #1 & #2 - TYPICAL SECTION No. Description SAND: 35 TO 60% 2 REVISIONS: NOTE: SEE TYPICAL TRENCH SECTION FOR BEDDING REQUIREMENTS bio-retention area seeding spec (Northeast Wetland Grass Seed Mix): 1 12" (I.D.) 12" Seed Mixture Variety Percent by No. of Seeds Creeping Bentgrass Agrostis stolonifera 63.0 TOP OF PIPE ZONE TYPICAL YARD DRAIN DETAIL Rough Bluegrass Meadow Foxtail Poa trivialis Alopecurus arundinaceus 17.0 11.0 12" Annual Ryegrass Lolium multiflorum 4.5 1 Deertongue Panicum clandestinum 4.5 . O.D. IA .) D D (I. 3H (6"MIN.) BASIN GRADE 1/3 I.D. (12"MAX.) HEAVY DUTY FRAME 1V AND GRATE, NEENAH R4832B, HS20-44, BICYCLE PROOF NOTES: RIM 674.80 A. PIPE INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. TOP OF POND 3:1 (H:V) MAX 3H ELEV. 675.30 SIDE SLOPE BASIN GRADE 10' B. TRENCHING OPERATIONS SHALL INCLUDE ALL NECESSARY DEWATERING. 1V C. TRENCH DETAILS ARE ONLY SHOWN FOR PURPOSES OF MATERIAL PLACEMENT AND MAXIMUM PAY LIMITS. PRECAST CONCRETE SPILLWAY ELEV. D. AN OSHA APPROVED MOVABLE PROTECTIVE TRENCH SHIELD SHALL CATCH BASIN UNIT, 674.80 BE USED IN ALL UNSHEETED TRENCH AREAS. KISTNER CB-2436 6" 2'-0" 6" OR EQUAL MIN. 6" FREEBOARD 100-YR FLOOD MATERIALS ELEV. 674.73 DRAWING NAME: 12" LIGHT STONE PIPE BEDDING MATERIAL (NYSDOT 1985 EDITION) FLOW INV 668.93 8" HDPE OUTLET PIPE FILL RIP-RAP Drainage Details 1 NO. 1 CRUSHED STONE OR CRUSHED GRAVEL WITH A GRADATION CONFORMING WITH NYSDOT SECTION 703-02. THE MATERIAL SHALL BE WELL GRADED WITH NO PARTICLES LARGER THAN ONE INV. 668.93 (SEE PLAN) EMERGENCY SPILLWAY DETAIL INCH AND HAVING A MAXIMUM GRADATION MEETING THE LIMITS DESCRIBED IN THE SUMP SPECIFICATIONS. THE BEDDING SHALL BE COMPACTED IN 6" LIFTS WITH EQUIPMENT INV 669.00 ACCEPTABLE TO THE PIPE MANUFACTURER. END SECTION 17 LF 8" HDPE @ 0.5% BOTTOM OF CB 667.93 NOT TO SCALE 6" NO SLAG SHALL BE ALLOWED FOR MATERIAL 1 Date: 5/22/26 2 BACKFILL MATERIAL SHALL BE NATIVE SOIL CONTAINING NO UNSUITABLE MATERIAL COMPACTED IN 6" LIFTS. Drawn By: A. Pandolfe 6" COMPACTED NYSDOT Scale: As Noted TYPE 2 R.O.C. STONE BASE NYSDOT ITEM 304.12 DRAWING NO. STORM SEWER TRENCH SECTION IN UNPAVED AREAS DETENTION BASIN OUTLET STRUCTURE NOT TO SCALE C-303 Project No: 23-4121 Page 1151 of 1493