Text · page 1330 of 1493
Read the whole document on one page (all 1493 pages, each with its own heading)
23-4121 storm calcs - Proposed Type II 24-hr 100-Year Rainfall=5.23" Prepared by Carmina Wood Design Printed 6/18/2026 HydroCAD® 10.20-8a s/n 05019 © 2025 HydroCAD Software Solutions LLC Page 58 Summary for Link 3L: Proposed - Total Inflow Area = 275,173 sf, 46.75% Impervious, Inflow Depth = 3.83" for 100-Year event Inflow = 4.61 cfs @ 12.01 hrs, Volume= 87,794 cf Primary = 4.61 cfs @ 12.01 hrs, Volume= 87,794 cf, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.50-70.02 hrs, dt= 0.04 hrs Link 3L: Proposed - Total Hydrograph Inflow 4.61 cfs Primary 5 4.61 cfs Inflow Area=275,173 sf 4 3 Flow (cfs) 2 1 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Time (hours) Page 1330 of 1493