E_App E_Post-Development Model  NY-West Seneca 24-hr S1 1-yr Rainfall=1.82"
Prepared by Labella Associates  Printed 4/20/2026
HydroCAD® 10.20-7a s/n 09581 © 2025 HydroCAD Software Solutions LLC  Page 6

  Summary for Subcatchment PS-1:

Runoff  =  0.72 cfs @ 12.04 hrs, Volume=  0.038 af, Depth= 0.72"
  Routed to Pond BIO-1 : Filtration Bioretention

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs
NY-West Seneca 24-hr S1 1-yr Rainfall=1.82"

  Area (sf)  CN  Description
  9,376  98  Paved parking, HSG D
  18,220  80  >75% Grass cover, Good, HSG D
  27,596  86  Weighted Average
  18,220  66.02% Pervious Area
  9,376  33.98% Impervious Area

  Tc Length  Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  6.0  Direct Entry, Direct

  Subcatchment PS-1:
  Hydrograph

  0.8  Runoff
  0.75
  0.72 cfs
  0.7  NY-West Seneca 24-hr S1 1-yr
  0.65  Rainfall=1.82"
  0.6  Runoff Area=27,596 sf
  0.55  Runoff Volume=0.038 af
  0.5  Runoff Depth=0.72"
  Flow (cfs)

  0.45  Tc=6.0 min
  0.4
  CN=86
  0.35
  0.3
  0.25

  0.2
  0.15
  0.1
  0.05
  0
  0 2  4 6  8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72
  Time (hours)

  Page 206 of 1493