The Soil Conservation Service defines the hydrologic soil groups as follows:
  •  Type A Soils: Soils having a high infiltration rate and low runoff potential when thoroughly wet.
  These soils consist mainly of deep, well drained to excessively drained sands or gravelly sands.
  These soils have a moderate rate of water transmission.
  •  Type B Soils: Soils having a moderate infiltration rate when thoroughly wet and consisting
  mainly of moderately deep to deep, moderately well to well drained soils with moderately fine
  to moderately course textures. These soils have a moderate rate of water transmission.
  •  Type D Soils: Soils having a very low infiltration rate and high runoff potential when thoroughly
  wet. These soils consist chiefly of clays that have high shrink-swell potential, soils that have a
  permanent high water table, soils that have a clay pan or clay layer at or near the surface, and
  soils that are shallow over nearly impervious material. These soils have a very low rate of water
  transmission.

 The soils map for the study area is presented in Appendix A, as Figure A-2.

 2.4 Watershed Designation

 The project site is not located in a restricted watershed identified in Appendix C of GP-0-25-001.

 2.5 Receiving Water Bodies

 The nearest natural classified water course into which runoff from the project site will discharge is
 Cayuga Creek. Cayuga Creek is classified by NYSDEC as a Class C water course, and is not included
 in the Section 303(d) list of impaired waters found in Appendix D of GP-0-25-001.

 2.6 Aquifer Designation

 The project site is not located over a US EPA designated Sole Source aquifer; nor is it located over a
 Primary or Principal aquifer listed in the NYSDEC Technical and Operational Guidance Series (TOGS)
 2.1.3 (1980).

 2.7 Wetlands

 A search on the NYSDEC Environmental Resource Mapper on April 16, 2026, and a review of GIS
 data, determined that there are no known regulated wetlands located on or in the vicinity of the project
 site. A wetland delineation is scheduled for Spring 2026 to field verify if there are any wetland on site.

 2.8 Flood Plains

 According to the National Flood Insurance Program Flood Insurance Rate Map (FIRM), Town of West
 Seneca, New York, Community, the project site lies within Flood Zone X, areas determined to be outside
 500-year floodplain The FEMA Flood Map has been provided in Appendix A, as Figure A-5.

Stormwater Pollution Prevention Plan
  Page 4
2241067
  Page 94 of 1493