Text · page 145 of 219
Read the whole document on one page (all 219 pages, each with its own heading)
122 OF 148 CITY OF LACKAWANNA • NY 2026 ZONING ORDINANCE | Chapter 300: Zoning E. Construction standards. iv. Proposed development shall not result in physical damage to 1. General standards. The following standards any other property (e.g., stream apply to new development, including new bank erosion or increased flood and substantially improved structures, in velocities). If requested by the local the areas of special flood hazard shown on administrator, the applicant shall the Flood Insurance Rate Map designated in provide a technical analysis, by Subsection C(2). a licensed professional engineer, a. Coastal high hazard areas and Coastal A demonstrating that this condition has Zones. The following requirements apply been met. within Zones V1-V30, VE and V: v. Proposed development shall be i. All new construction, including designed, located, and constructed manufactured homes and so as to offer the minimum resistance recreational vehicles on site 180 to the flow of water and shall be days or longer and not fully licensed designed to have a minimum effect for highway use, shall be located upon the height of floodwater. landward of the reach of high tide. vi. Any equipment or materials located ii. The use of fill for structural support in a special flood hazard area shall be of buildings, manufactured homes or elevated, anchored, and floodproofed recreational vehicles on site 180 days as necessary to prevent flotation, or longer is prohibited. flood damage, and the release of iii. Man-made alteration of sand dunes hazardous substances. which would increase potential flood vii. No alteration or relocation of a damage is prohibited. watercourse shall be permitted unless: b. Subdivision and development proposals. The following standards apply to all (A) A technical evaluation by a new subdivision proposals and other licensed professional engineer proposed development in areas of special demonstrates that the altered or flood hazard (including proposals for relocated segment will provide manufactured home and recreational conveyance equal to or greater vehicle parks and subdivisions): than that of the original stream segment and will not result in i. Proposals shall be consistent with the physical damage to any other need to minimize flood damage. property; ii. Public utilities and facilities such as sewer, gas, electrical and water systems shall be located and constructed to minimize flood damage. iii. [Adequate drainage shall be provided to reduce exposure to flood damage.