PART 5 District Regulations  39 OF 148

§5-10  LIGHT INDUSTRY OVERLAY (LI)
A. Purpose. The primary purpose of the Light  D. Accessory Uses and Structures. The following
  Industry Overlay District is to encourage  are permitted in the Light Industry Overlay
  the development of a mix of uses, such as  District:
  offices, research and development facilities,
  1.  Communication towers/dishes required for
  wholesale, warehousing/distribution, and light
  operation of primary use;
  manufacturing uses, with the intent of offering
  a wide range of job opportunities with a focus  2.  Employee services, such as cafeterias, credit
  on contributing to the City’s tax base. Properties  unions and recreational facilities, which are
  in the BRA-LI are visible from New York State  located within the primary structure and
  Route 5 and/or the Hamburg Turnpike and help  occupy no more than 10% of the developed
  establish the image of the area. Development in  floor area;
  this district is subject to higher design standards  3.  Satellite television receiving antenna;
  in order to present an attractive setting.
  4.  Truck shipping and delivery facilities
B. Principal and Special Uses. The Permitted  accessory to primary operation;
  principal uses within this overlay district are listed
  5.  Warehouse and distribution facilities ancillary
  in the use schedule in §4-1.
  to the primary use and limited to a floor area
  not to exceed 35% of the gross floor area of
C. Dimensional Standards  the primary use; and,

ACCESSORY USE/STRUCTURE  STANDARDS  6.  Rooftop solar energy system apparatus, if
  not visible from a public right-of-way, and
Minimum Lot Size  5 Acres; or 50 Acres for PUD  if attached to a primary structure, and if
Minimum Lot Frontage  300 ft.  not creating an exceedance of area height
  restrictions measured from top of apparatus
Maximum Building Height  45 feet or 3 Stories  to ground [Amended 3-29-2021].

Minimum Front Yard  30 ft./50-foot Setback Required  E. Accessory Use and Structure Dimensional
  from New York State Route  Standards. Accessory use and structures shall
  5 Right-of-Way/Hamburg  meet the minimum dimensional requirements
  Turnpike Right-of-Way  of the principal uses and structures of the Light
  Industrial Overlay District.
Minimum Side Yard  25 ft.

Minimum Rear Yard  N/A

Minimum Buffer to Smokes
  50 ft.
Creek Mean Water Line

Minimum Building Coverage  15%

Maximum Lot Coverage  75%

Minimum Landscaping
  25%
Coverage

Minimum Setback for Parking
  10 ft.
from Right-of-Way