Text · page 78 of 219
Read the whole document on one page (all 219 pages, each with its own heading)
PART 7 General Development Standards 55 OF 148 §7-4-8 Enforcement and 3. Multi-family dwellings over four units. Maintenance B. Lighting Plan. A lighting plan shall be submitted as part of the site plan review process. Lighting A. All landscaped areas required and/or permitted plans must be prepared by a lighting professional by these regulations shall be maintained and just include the following: and preserved according to the approved landscape plan. Landscaped areas shall be 1. Location of all exterior lights and their kept free of trash, litter, weeds and other such specifications. materials. Failure to maintain the landscaping 2. The level of illumination at each property line, in accordance with the approved landscape measured in footcandles. plan or to keep landscaped areas free of trash, 3. Height of pole and fixture and/or distance litter, weeds and other such materials shall be a above grade for wall-mounted lighting violation of this Ordinance, and this requirement fixtures. shall be enforced by the Code Enforcement Office. 4. A detail of the proposed light fixtures and any shielding. B. All plant materials provided for a development in accordance with the approved landscape C. The following minimum lighting levels shall be plan shall be in a healthy and vigorous provided for uses requiring site plan review: growing condition and exhibit good form. All 1. Parking lots: 0.5 footcandles. plant materials which are considered to be 2. Driveways: 0.25 footcandles. unacceptable for the purposes of compliance with these regulations shall be replaced with 3. Pedestrian walkways: 0.18 footcandles. acceptable plant material prior to the issuance of 4. Building entrances: 0.5 footcandles. a final Certificate of Occupancy or Certificate of 5. Accent illumination: 0.5 footcandles. Compliance by the Code Enforcement Office. D. All outdoor lighting shall be designed and located C. Plantings intended to serve as a visual screen such that the maximum illumination measured which die or are not maintained in a healthy in footcandles at the property line does not and growing condition after three years from exceed 0.2 on adjacent residential use, and the date of issuance of the final Certificate of 0.5 on adjacent commercial sites and public Occupancy or Certificate of Compliance by the rights-of-way. Code Enforcement Office shall be replaced with plantings of a size and nature sufficient to achieve E. Light sources shall not be higher than 20 feet; the visual screen intended. pedestrian light fixtures shall not exceed 15 feet in height. §7-5 LIGHTING F. Security lighting fixtures and exterior wall- A. Applicability. These regulations shall apply to all mounted floodlights are restricted to enclosed exterior lighting on any property utilized for the service courtyards. following purposes: G. High intensity lighting is prohibited. 1. Nonresidential uses, including industrial uses; 2. Mixed-uses, whether located on the same site or within the same structure; and,