12" #3 DOWEL @ 24" O.C.,
  LOCATE AT MID-POINT OF
  DEPTH OF SIDEWALK, EMBED 4"  FINISH GRADE 1" BELOW TOP OF CURB IN ALL LAWN
  6"  INTO CURB  6"  AREAS. TOP OF SOD TO BE FLUSH WITH TOP OF CURB
  AS SHOWN
sections 7209N and 7301 of the New York State Education Law for any person, unless acting under the direction of a registered architect, licensed engineer or land surveyor

  1"  5"  1"  5"
to alter this drawing. If altered such R.A., P.E. or L.L.S. shall affix his or her seal, signature, the date,the notation "Altered By" and a specific description of the alteration.

  1" RADIUS  SIDEWALK, SEE DETAIL  1" RADIUS
All Rights Reserved. Reuse of these documents without the expressed written permission of CARMINAWOOD DESIGN is prohibited. WARNING it is a violation of article 145

  SOD

  Greensboro
  PAVING AS  PAVING AS  SEE  PAVEMENT WIDTH VARIES SEE SITE PLAN

  6"

  6"
  SPECIFIED  SPECIFIED  4" LAYER TOPSOIL  TRAFFIC REFLECTIVE  PLAN
  SIDEWALK SUBBASE  STOP SIGN -
  2'-0"

  1'-6"

  1'-6"
  WHITE PAINT  6" CONCRETE SLAB (MIN. 4000 PSI)

  1'-0"

  1'-0"
  TACK COAT PRIOR TO  M.U.T.C.D. SIGN
  TACK COAT PRIOR TO  CONTROL JOINTS @ 10' O.C. BOTH WAYS. SEAL
  PAVING  NO. R1-1  ALL JOINTS WITH ASPHALT CEMENT, NYSDOT
  PAVING  SPECIFICATIONS 702-0700
  4'-0"
  3,500 PS1 CONCRETE  3,500 PS1 CONCRETE  1'-6"  2'-0"  6"x6" 10/10 WELDED WIRE FABRIC

  CENTER LINE TWO LANE PAVEMENT
  PAVEMENT ELEVATION &  PAVEMENT ELEVATION & DIMENSION  STOP BAR  (3" BELOW TOP OF SLAB)
  DIMENSION REFER TO THIS POINT  REFER TO THIS POINT

  STOP  X  X  X  X  X  X  X

  Utica
  8'-0"
  MIN 6" STONE MATERIAL UNDER CURB  MIN 6" STONE MATERIAL UNDER CURB  8" SUBBASE COURSE
  TYPE 2 (N.Y.S.D.O.T. ITEM 304.12)  TYPE 2 (N.Y.S.D.O.T. ITEM 304.12)  MATERIAL, TYPE 1
  FACE OF CURB OR  (NYSDOT ITEM 304.11)
  EDGE OF PAVEMENT,
  ABUTTING SIDEWALK  ABUTTING LANDSCAPE/GRASS  SEE PLAN  GRADED AND COMPACTED PAVEMENT SUBGRADE

  Buffalo
  NOTES:  51/2"  1'-8"
  (TYP)  NOTE: CONCRETE PAVEMENT MATERIAL SHALL CONFORM TO NYSDOT
  1. CONTROL JOINTS TO BE 2" DEEP AT 15'-0" O.C. - SEE SPECIFICATIONS FOR FURTHER JOINT REQUIREMENTS NYSDOT 702-0700.  8'-5"  STANDARD SPECIFICATION 501 AND CONSTRUCTION METHODS
  2. WHERE THE CURB DROPS (IS FLUSH WITH ASPHALT) THE DEPTH OF CURB BELOW GRADE SHALL BE INCREASED TO 1'-6" AND  CENTERED IN LANE  SHALL CONFORM TO NYSDOT STANDARD SPECIFICATION 502-3.
  OTHER DIMENSIONS ADJUSTED ACCORDINGLY.  SEE PLAN

  EXTERIOR CONCRETE
  TYPE "A" CONCRETE CURB - 1  STOP BAR DETAIL - 3  SLAB-ON-GRADE SECTION - 9
  NOT TO SCALE  NOT TO SCALE
  NOT TO SCALE

  PAVEMENT WIDTH VARIES SEE SITE PLAN
  1" ASPHALT TOP COURSE, TYPE 7  2'-0"
  (N.Y.S.D.O.T. ITEM 403.18)  TYP.  NOTE:CROSS SLOPE WITHIN
  3" ASPHALT BINDER COURSE, TYPE 3  NEW CONCRETE (MIN. 3,500 PSI) NYSDOT R.O.W. IS 1.5% MAX.

  TYP.
  (N.Y.S.D.O.T. ITEM 403.13)  EXPANSION JOINT  SIDEWALK - 4" MIN. THK.

  2'-0"
  1/2 " RECESS  DRIVEWAY - 6" MIN THK. W/W.W.F.6X6/10X10  B  A

  5'-0"
  10" SUBBASE COURSE MATERIAL, TYPE 1  1'R  SLOPE
  (N.Y.S.D.O.T. ITEM 304.02)  EXISTING SIDEWALK  GRASS AREA

  4'-0"
  1/4 "/FT.  CURB  50% - 65% of
  3'R  base dia.  CURB

  1:1

  West Seneca Exchange
  PAVEMENT  EXPANSION JOINT

  2
  TACTILE WARNING  1:12  1/2 " RECESS
  5'-0"  4'-0"  FIELD, COLOR TO  A
  1'-0"  CONTRAST WITH RAMP  1:12
  NONWOVEN GEOTEXTILE  TYP.  5'-0  B
  FABRIC MIRAFI 600X OR  FORM SUBBASE  STONE SUBBASE MATERIAL  MATERIAL  "M

  Slade Ave, Ridge Rd & Orchard Park Rd
  0.9"  IN.

  0.2"
  APPROVED EQUAL  CROSS SECTION  TYPE 2 (N.Y.S.D.O.T. ITEM 304.12)
  MIN. 4" THK (SIDEWALK)
  MIN. 6" THK (DRIVEWAY)  DOME SECTION
  GRADED AND COMPACTED PAVEMENT SUBGRADE  PAINTED TRAFFIC ARROWS - 4  NOTES:
  TO BE FLUSH WITH
  EDGE OF PAVEMENT
  NOT TO SCALE
  1. CONTROL JOINTS TO BE AT 5'-0" O.C., BOTH WAYS WHERE APPLICABLE. SEE SPECIFICATIONS FOR FURTHER JOINT
  NOTE: CONSTRUCTION METHODS FOR ASPHALT PAVEMENT SHALL  REQUIREMENTS NYSDOT 702-0700.  2.35"  1"  CURB
  CONFORM TO NYSDOT STANDARD SPECIFICATION 401-3, WITH  typ.  HIGHWAY
  dome (typ.)  PAVEMENT  RAMP
  SUBBASE CONSTRUCTION METHODS CONFORMING TO NYSDOT  SIDEWALK

  2.35"
  5' MIN.  2.  CONCRETE SIDEWALK AND DRIVEWAY MATERIAL SHALL CONFORM TO NYSDOT STANDARD SPECIFICATION 501 AND
  STANDARD SPECIFICATION 304-3.  CONSTRUCTION METHODS SHALL CONFORM TO NYSDOT STANDARD SPECIFICATION 608-3.
  6" CONCRETE (MIN. 3500 PSI) W/6X6

  2'
  3.  SUBBASE GRADE SHALL FOLLOW THE PROPOSED GRADE OF THE SIDEWALK AND SLOPE AWAY FROM BUILDING WHERE  10/10 WWM 4" STONE SUBBASE
  HEAVY DUTY ASPHALT SECTION - 2

  West Seneca New York
  APPLICABLE, PROVIDE CONTINUOUS STONE PATH TO CURB UNDERDRAIN WHERE PROVIDED.  SECTION A-A
  WHITE PAVEMENT

  typ.
  NOT TO SCALE  PAINT

  1"
  4.  FULL DEPTH EXPANSION JOINTS SHALL BE INSTALLED EVERY 20' O.C., BOTHWAYS WHERE APPLICABLE. SEE  DOME SPACING  1:12 5'-0" MIN.  1:12
  © CARMINA WOOD DESIGN

  SPECIFICATIONS FOR FURTHER JOINT REQUIREMENTS NYSDOT 702-0700.  PAVEMENT SURFACE
  SIDE SLOPE RAMP  SIDE SLOPE
  NOTE: TACTILE WARNING
  FIXTURE FURNISHED,  5.  SEE CURB DETAIL FOR DOWLING REQUIREMENTS WHERE ABUTTING CURB.  DEVICES SHALL BE PER ICC/ANSI
  24"

  INSTALLED AND WIRED BY ELECTRICAL  A117.1-1998, SECTION 705.3.1.2  CURB
  12"

  CONTRACTOR.  6.  INSTALL 6" LONG #3 DOWELS @ 12" O.C. WHERE SIDEWALK ABUTS A BUILDING WALL AT AN ENTRANCE, THICKEN SIDEWALK  OR CURRENT UPDATE  SECTION B-B
  TO 6" AT BUILDING WALL AND INSTALL DOWEL CENTERED IN THE 6" DEPTH. DOWELS AND THICKENING OF SIDEWALK
  SHALL EXTEND 18" EITHER SIDE OF ENTRANCE.
  4" WHITE
  7.  INSTALL 1/2" PREMOLDED EXPANSION JOINT WITH BACKER ROD & SEALANT WHERE SIDEWALK ABUTS BUILDING OR OTHER
  SIDEWALK CURB RAMP - 7
  PAVEMENT  NOT TO SCALE
  STRUCTURE.
  ELECTRICAL CONTRACTOR FURNISHED POLE  STRIPE
  4"x6" GASKET HAND HOLE  25' HEIGHT UNLESS OTHERWISE NOTED
  ELECT. CONTRACTOR TO
  CONNECT OR CADWELD
  GROUND WIRE TO
  FURNISHED AND INSTALL IN-LINE
  BALLAST FUSES IN BUSSMANN
  CONCRETE SIDEWALK - 6
  "TRON" WEATHERPROOF FUSE  NOT TO SCALE
  1"x45° CHAMFER  HOLDERS #HEB-AD WITH #KTK
  ROUND FORMED CONCRETE
  BASE 24" DIAMETER
  FUSES (SIZE AS REQUIRED)
  4 - 40"x1"Ø ANCHOR BOLTS
  CROSSWALK STRIPING - 8

  Date
  NOT TO SCALE
  #3 REINFORCING TIES
  12" ON CENTER
  SEE NOTE

  FINISHED GRADE
  #6 BARE GROUND WIRE
  CADWELD CONNECTION
  3'-0" MIN.

  (BOTH ENDS)
  6'-0" MIN. AND DOWN

  3/4 "x10" COPPER WELD
  TO SOLID BEARING

  GROUND ROD (LIGHTING
  PROTECTION)
  CARLON PLASTIC CONDUIT

  No. Description
  3" COVER  GALVANIZED STEEL TO CARLON
  CONDUIT CONNECTOR

  REVISIONS:
  GALVANIZED CONDUIT "ELL"
  4 - #8 VERTICAL
  REINF. BARS
  ALL CONCRETE WORK AND
  REINFORCING SHALL BE  24" DIA.
  BY SITE CONTRACTOR  CONCRETE
  BASE
  NOTES:
  1. FOR LOCATIONS OF FOUNDATIONS SEE SITE PLAN
  2. FOR LIGHT FIXTURE ORDERING INFORMATION SEE SITE LIGHTING PLAN
  3. LIGHT POLE BASE EXPOSURE ABOVE GRADE SHALL BE:
  IN CURBED ISLANDS: 6" ABOVE TOP OF CURB ELEVATION
  IN PAVEMENT: 3' ABOVE GRADE
  IN NON-CURBED GRASS AREAS: 6" ABOVE GRADE

  Sealed 07/20/2026
  LIGHT POLE FOUNDATION - 5
  NOT TO SCALE

  DRAWING NAME:

  Site Details

  Date:  07/20/26
  Drawn By:  C. Wood
  Scale:  As Noted
  DRAWING NO.

  C-104
  Project No:  24-4113

  Page 1052 of 1174