Southtowns Record

PB Agenda Packet 8.13.2026

Government
Town of West Seneca
Board
Planning Board
Meeting
Aug 13, 2026, 6:00 p.m.
Posted by publisher
Jul 28, 2026
Kind
Agenda packet
Topics
Water, sewer and drainage, Roads and traffic, Housing, Zoning and land use, Parks and recreation, Budget and taxes, Public safety

Original document

Same meeting

Text · page 1092 of 1174

Read the whole document on one page (all 1174 pages, each with its own heading)

Land Surveying
  Environmental
  STOP

  Architecture
  Engineering
  ZONING INFORMATION
  LOCATION: WEST SENECA, ERIE COUNTY, NEW YORK

  ZONE: M-1 (MANUFACTURING)  610
  605
  USE: RETAIL (PERMITTED USE), WAREHOUSE (PERMITTED USE), GAS STATION (SPECIAL PERMIT USE)

  ITEM  REQUIREMENTS  PROPOSED  VARIANCE

  787,828 S.F.
  MINIMUM LOT AREA  NONE REQUIRED  NO

  STOP
  (18.08 AC.)  605

  MINIMUM LOT WIDTH  NONE REQUIRED  760 FEET  NO

  STOP
  SHEET C1.01  SHEET C1.02
  MINIMUM LOT FRONTAGE  NONE REQUIRED  1,840 FEET  NO
  RESTAURANT 2,380 SF
  25 FEET OR

  605
  355 Research Parkway

  605
  MINIMUM FRONT SETBACK  159 FEET  NO  FUTURE DRIVE-THRU
  50 FEET WHEN OPPOSITE ANY R DISTRICT  RETAIL
  Meriden, CT 06450
  MINIMUM SIDE SETBACK  10 FEET  45 FEET  NO  2,925 G.S.F.  (203) 630-1406
  610
  MINIMUM REAR SETBACK  10 FEET  N/A  NO  615
  FUTURE
  MAXIMUM BUILDING HEIGHT  40 FEET  ±33 FEET  NO  STOP
  615
  615
  615  615
  MAXIMUM BUILDING COVERAGE  NONE REQUIRED  24 PERCENT  NO
  615

  615  615  615  615
  615

  615
  615

  PARKING INFORMATION  615

  ITEM  REQUIREMENTS  PROPOSED  VARIANCE

  BUILDING SIZE  NONE REQUIRED  187,050 S.F.  NO
  7/17/2026
  RETAIL:
  5 SPACES PER EVERY 1000 S.F. OF GROSS  RESTAURANT 2,380 SF
  FLOOR AREA (160,000 S.F.) = 800 SPACES  FUTURE DRIVE-THRU
  TIRE CENTER:
  3 SPACES FOR EACH SERVICE BAY = 15 SPACES

  WAREHOUSE:
  PARKING REQUIRED  1 SPACE FOR EACH 1000 S.F. OF GROSS FLOOR  812 SPACES  YES
  AREA USED FOR SUCH PURPOSED, BUT SHALL

  CAUTION

  CAUTION
  CAUTION

  CAUTION
  E
  NOT BE LESS THAN 1 SPACE FOR EACH 2
  EMPLOYEES AND NEED NOT BE MORE THAN 1

  U
  FOR EACH 1.5 EMPLOYEES (18,000 SF) =
  18 SPACES

  EN
  TOTAL REQUIRED: 833

  MINIMUM ADA PARKING SPACES REQUIRED  17 SPACES  17 SPACES  NO

  AV

  COSTCO WHOLESALE
  RETAIL:

  E

  WEST SENECA, NEW YORK
  3 SPACES FOR GROSS FLOOR AREA OVER

  D
  50,000 S.F.
  MINIMUM LOADING SPACES  5 SPACES  NO
  WAREHOUSE:
  2 SPACES FOR GROSS FLOOR AREA UNDER

  L A

  SLADE AVENUE
  40,000 S.F.

  S

  CAUTION
  MINIMUM PARKING DIMENSIONS  9 FEET X 18 FEET  10 FEET X 20 FEET  NO

  CAUTION

  CAUTION
  CAUTION

  CAUTION

  CAUTION

  CAUTION
  CAUTION

  CAUTION
  CAUTION
  MINIMUM AISLE WIDTH  NONE REQUIRED  24 FEET - 2-WAY  NO

  MINIMUM FRONT SETBACK  10 FEET  10 FEET  NO
  MINIMUM SIDE SETBACK  NONE REQUIRED  10 FEET  NO
  MINIMUM REAR SETBACK  NONE REQUIRED  28 FEET  NO
  10' WIDE MEDIANS NOT PROVIDED BETWEEN
  10' WIDE MEDIANS BETWEEN PARKING BLOCKS
  EVERY PARKING BLOCK
  DRIVE AISLES AND LANDSCAPED ISLANDS
  MORE THAN 20 PARKING SPACES IN A ROW
  SHALL BE INSTALLED SO THAT NOT MORE THAN
  MINIMUM INTERIOR LANDSCAPING  YES
  20 PARKING SPACES IN A SINGLE ROW OR 40 IN WITHOUT INTERRUPTION
  A DOUBLE ROW GO UNINTERRUPTED
  FOR 812 PARKING SPACES, 82 SHADE TREES
  1 SHADE TREE PER 10 PARKING SPACES  ARE REQUIRED AND PROVIDED
  10% OF REQUIRED VEHICLE PARKING
  MINIMUM BICYCLE PARKING  (MAXIMUM OF 20 BICYCLE SPACES)  20 SPACES  NO

  SIGN LEGEND
  CAUTION

  SIGN NO.  MUTCD NO.  LEGEND
  RID

  CAUTION

  ±18K S.F. MDO
  A  R1-1
  STOP  30"
  GE

  VIOLATORS WILL
  BE FINED

  B  R7-8  FFE = ±620.60
  ROA

  HANDICAPPED  CAUTION

  PARKING

  158K PROTO
  STATE PERMIT
  REQUIRED

  812 PARKING SPACES
  CAUTION

  VAN
  D

  C  R7-8P  ACCESSIBLE

  SHEET C1.03  SHEET C1.04  DN

  Desc.
  DN

  D  R5-1

  REVISIONS
  DateNo.
  E  R3-8

  Xref (s): ; XY240182401 ; XC2401824-10 ; XB2401824-00 ; XO2401824-01 ; KM2401824-KeyMap
  ONLY ONLY

  Designed  J.J.L.
7/17/2026, KKILGUSS, G:\JOBS24\18\2401824\DWG\C2401824-10.DWG.C1.00 24X36 60SC.

  Drawn  J.J.L.
  NOTE: ALL HANDICAP ACCESSIBLE PARKING STALL SIGNAGE TO BE INSTALLED IN PIPE BOLLARDS (SEE  Reviewed  K.A.K.
  DETAIL) AND BE IN FULL COMPLIANCE WITH THE LATEST BUILDING CODE.  Scale  1"=60'
  Project No.  2401824
  Date  07/17/2026
  CAD File:
  C2401824-10

  Title

  OVERALL SITE PLAN

  Sheet No.

  C1.00
  GRAPHIC SCALE

  ISSUED FOR PERMITTING  60  30  0  60

  NOT RELEASED FOR CONSTRUCTION  SCALE IN FEET

  C 2026 BL COMPANIES, INC. THESE DRAWINGS SHALL NOT BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION WITHOUT THE SPECIFIC WRITTEN PERMISSION OF BL COMPANIES.

  Page 1092 of 1174