Southtowns Record

PB Agenda Packet 8.13.2026

Government
Town of West Seneca
Board
Planning Board
Meeting
Aug 13, 2026, 6:00 p.m.
Posted by publisher
Jul 28, 2026
Kind
Agenda packet
Topics
Water, sewer and drainage, Roads and traffic, Housing, Zoning and land use, Parks and recreation, Budget and taxes, Public safety

Original document

Same meeting

Text · page 1096 of 1174

Read the whole document on one page (all 1174 pages, each with its own heading)

Land Surveying
  Environmental
  SITE PLAN LEGEND  20'  24'  20'  20'  24'  20'  20'  24'  20'  20'  30'  20'  20'

  Architecture
  Engineering
  10'  10'  10'
  6'
  30'  20'  24'  20'  20'  30'  20'  20'  24'  20'  20'  24'  40'  30'
  PROPERTY LINE
  12'
  EASEMENT LINE  (TYP.)
  PROVIDE AND INSTALL 5 MDO SHIPPING TRUCK STALLS
  LIMIT OF DISTURBANCE AND SITEWORK CONTRACT
  LIMIT LINE
  SAWCUT LINE
  PROVIDE AND
  PROVIDE AND INSTALL CONCRETE CURB AND GUTTER  INSTALL FLUSH
  BITIMOUNOUS
  PROVIDE AND INSTALL CONCRETE PAVEMENT  WALK AT
  STRUCTURE, REINFORCED CONCRETE SIDEWALK, OR  ACCESSIBLE
  MONOLITHIC CONCRETE CURB AND SIDEWALK  PARKING (TYP.)
  PROVIDE AND INSTALL CONCRETE
  LANDSCAPE EDGING (TYP.)

  R=1
  PROVIDE AND INSTALL FULL DEPTH HEAVY DUTY

  5'
  BITUMINOUS CONCRETE PAVEMENT STRUCTURE  355 Research Parkway

  5'

  R=
  ALL RADII TO BE 3' UNLESS  Meriden, CT 06450
  PROVIDE AND INSTALL DETECTABLE  (203) 630-1406
  WARNING PAD (TYP.)  596 PARKING SPACES  OTHERWISE NOTED (TYP.)
  PROVIDE AND INSTALL FULL DEPTH STANDARD  30'  30'
  DUTY BITUMINOUS CONCRETE PAVEMENT
  STRUCTURE  10'
  (TYP.)
  R=
  METAL BEAM GUIDERAIL  29
  '
  20'  PROVIDE AND INSTALL LIGHT POLE,
  PROVIDE AND INSTALL SIGN
  FIXTURE, AND CONCRETE BASE.
  REFER TO LIGHTING PLAN (TYP.)
  180'
  PERMISSIBLE BUILD AREA
  PER BK. 10872 PG. 9162
  PROVIDE AND INSTALL BOLLARD AT RETAINING
  WALL. EXACT LOCATION OF BOLLARDS TO BE FIELD
  PROVIDE AND INSTALL
  PROVIDE AND INSTALL BOLLARDS  LOCATED TO ADEQUATELY PROTECT THE WALL (TYP.)
  RUBBER WHEELSTOP (TYP.)  7/17/2026
  AT GAS METER (TYP.)  PROVIDE AND CONCRETE PAVEMENT STRUCTURE,
  PROVIDE AND INSTALL CONCRETE PAVEMENT
  STRUCTURE, SEE ARCHITECTURAL  PROVIDE AND INSTALL PAINTED  SEE STRUCTURAL PLANS FOR DETAIL (TYP.)
  DRAWINGS FOR DETAILS  ISLAND, 4" SWL 2' O.C. AT 45° (TYP.)
  PROVIDE AND INSTALL CONCRETE TRANSFORMER
  PROVIDE AND INSTALL BOLLARD AT STAIRS. EXACT  PAD AND BOLLARDS IN ACCORDANCE WITH
  LOCATION OF BOLLARDS TO BE FIELD LOCATED TO  ELECTRIC COMPANY STANDARDS.
  ADEQUATELY PROTECT THE WALL (TYP.)
  EXISTING PROPERTY
  LINE (TYP.)

  DEVELOPER'S PLAN BY OTHERS

  COSTCO WHOLESALE
  10'
  50'

  ±18K S.F. MDO

  WEST SENECA, NEW YORK
  SLADE AVENUE
  FFE = ±620.60
  158K PROTO  66'

  PROPOSED PROPERTY LINE (TYP.)

  812 PARKING SPACES
  PROPERTY LINE SHALL BE LIMIT OF DISTURBANCE AND SITEWORK
  CONTRACT LIMIT LINE UNLESS OTHERWISE SHOWN (TYP.)

  10' SIDE BUILDING SETBACK (TYP.)
  PROVIDE AND INSTALL TIRE SERVICE CENTER

  SHEET 1.01  SHEET 1.02
  DN

  PROVIDE AND CONCRETE PAVEMENT STRUCTURE,
  SEE STRUCTURAL PLANS FOR DETAIL (TYP.)
  DN
  CAUTION

  CAUTION
  CAUTION

  CAUTION
  CAUTION

  CAUTION

  CAUTION
  CAUTION

  CAUTION

  CAUTION

  CAUTION
  CAUTION

  CAUTION
  CAUTION

  PROVIDE AND INSTALL BOLLARDS AT
  BUILDING CORNER (TYP. OF 3)
  EXACT LOCATION OF BOLLARDS TO BE
  FIELD LOCATED TO ADEQUATELY PROTECT
  CAUTION
  THE BUILDING CORNERS (TYP.)
  CAUTION

  PROVIDE AND INSTALL RETAINING
  WALL. SEE STRUCTURAL DRAWINGS
  CAUTION
  FOR DETAILS. (TYP.)
  CAUTION

  110'  PROVIDE AND INSTALL BOLLARD AT RETAINING
  DN
  DN

  WALL. EXACT LOCATION OF BOLLARDS TO BE FIELD
  LOCATED TO ADEQUATELY PROTECT THE WALL. SEE
  STRUCTURAL DRAWINGS FOR DETAILS (TYP.)

  Desc.
  SHEET 1.03  SHEET 1.04
  35'
  45'

  REVISIONS
  '
  R=45

  Date
  KEY MAP

  No.
  10'

  Xref (s): ; XY240182401 ; XC2401824-10 ; XB2401824-00 ; XO2401824-01 ; KM2401824-KeyMap
  PROVIDE AND INSTALL CONVEX MIRROR
  PROPOSED LIGHT POLE IN CLOSED PROXIMITY  Designed  J.J.L.
  PERMISSIBLE BUILD AREA  PROVIDE AND INSTALL HEAVY  PROVIDE AND INSTALL CURB & GUTTER (TYP.)  10' SIDE BUILDING SETBACK (TYP.)  TO ELECTRICAL LINES. COORDINATION WITH  Drawn  J.J.L.
  PER BK. 10872 PG. 9162  DUTY BITUMINOUS CONCRETE  UTILITY PROVIDER REQUIRED. (TYP)
7/17/2026, JLYNN, G:\JOBS24\18\2401824\DWG\C2401824-10.DWG.C1.04 24X36 30SC.

  Reviewed  K.A.K.
  PAVEMENT STRUCTURE (TYP.)
  Scale  1"=30'
  Project No.  2401824
  Date  07/17/2026
  CAD File:
  C2401824-10

  Title

  SITE PLAN

  Sheet No.

  C1.04
  GRAPHIC SCALE

  ISSUED FOR PERMITTING  30  15  0  30

  NOT RELEASED FOR CONSTRUCTION  SCALE IN FEET

  C 2026 BL COMPANIES, INC. THESE DRAWINGS SHALL NOT BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION WITHOUT THE SPECIFIC WRITTEN PERMISSION OF BL COMPANIES.

  Page 1096 of 1174