Text · page 1098 of 1174
Read the whole document on one page (all 1174 pages, each with its own heading)
Land Surveying Environmental PAINT (2) COATS SAFETY YELLOW - Architecture Engineering PAINT (2) COATS SAFETY YELLOW - 1'-0" RADIUS - TYP EXTEND FULL WIDTH OF CART CORRAL 3' - 0" RADIUS 1' - 0" RADIUS - 1'-0" RADIUS - TYP EXTEND FULL WIDTH OF CART CORRAL CONFIRM DEPTH WITH CIVIL DRAWINGS CONFIRM DEPTH WITH CIVIL DRAWINGS 1'-0" CONFIRM DEPTH WITH CIVIL DRAWINGS CONFIRM DEPTH WITH CIVIL DRAWINGS TYPICAL TYPICAL 2'-0" 2'-0" 2' - 0" TYPICAL 1'-0" 1'-6" 9'-6" 20'-0"(UNO) CURB AT CURB AT GALV PIPE 4" WIDE 20'-0"(UNO) ISLAND END END ISLAND 4" WIDE GALV PIPE RAILS - TYP PAINTED 20' - 0" 10' - 0" (UNO) 4" WIDE PAINTED 6" HIGH CONCRETE CURB PAINTED RAILS - TYP LINES - 8' - 0" LINES - LINES - SEE SPECS SEE SPECS EQ EQ SEE SPECS STEP OFF WALK 9'-6" CONCRETE SLAB - SLOPE AWAY WHERE SHOWN FROM POLE BASE CART CORRAL CART CORRAL ELEVATION 355 Research Parkway EQ ELEVATION Meriden, CT 06450 8' - 0" (203) 630-1406 CURB AT ISLAND EQ WALK SURFACE 1'-8" 1'-8" 1'-0" 1'-0" LIGHT POLE BASE 1'-0" 8'-8" 8'-0" 20'-0"(UNO) 1'-0" 20'-0" (UNO) 1'-6" 1'-6" 1'-0" 1'-0" 1'-8" 8'-8" 1'-8" 8'-0" 12'-0" 20' - 0" (UNO) 4" 4" (UNO) TYPICAL 9'-0" 9'-0" 12'-0" 8'-0" 1'-0" 1'-0" PLANTER AREA 16' - 0" PLANTER TYP TYP PER LANDSCAPING AREA PER 4" WIDE PAINTED LINES - LANDSCAPING SEE SPECIFICATIONS RUBBER RUBBER CART STOP 1' - 0" RADIUS / TYPICAL CART STOP 2'-0" 1'-0" 7/17/2026 2'-0" 10'-0" 10'-0" 10'-0" 3'-0" 3'-0" 10'-0" 10'-0" 9'-0" 10'-0" 10'-0" 10'-0" 10'-0" (UNO) (UNO) (UNO) (UNO) (UNO) (UNO) (UNO) (UNO) (UNO) VARIES PER PLAN ISLAND AT LIGHT POLE END ISLAND CURBS MIDDLE ISLAND AT CART CORRAL CART CORRAL & TYPICAL PARKING STALL PAINT (2) COATS SAFETY AT ISLAND AT LANDSCAPING YELLOW - CENTER TEXT TO STALL SLOPE SLOPE HAND HOLE / COVER FIBERGLASS POLE - SEAT OVER STUB ONLY FIBERGLASS OR ALUMINUM STUB (DASHED) COSTCO WHOLESALE PARKING IDENTIFICATION LABEL (BY POLE MANUFACTURER) TIRE EMBED IN CONCRETE AND PROJECT ABOVE BASE WEST SENECA, NEW YORK INFLATION INFLATION PARKING FIBERGLASS OR NOTE: TIRE ALUMINUM STUB - 4'-0"TO CENTERLINE INSERTION DEPTH AND INSTALLATION IS CORRECT ONLY 524 NITROGEN AIR TOWER - OF LIGHT POLE SEE A504 PROJECT ABOVE IF THE BOTTOM OF POLE IS RECESSED BELOW 3'-0"MIN CONCRETE CONCRETE SURFACE AT LEAST 1/2" AND THE POLE DRILL (1) 1/4" DIAMETER LIGHT POLE IS A TIGHT FIT WITH THE FOUNDATION STUB SLADE AVENUE (UNO) 3'-6" 20'-0" ASPHALT BASE DIMENSION WEEP HOLE THRU BOTH CRITICAL 6" CONCRETE BASE TYP - FIBERGLASS SHAFT AND SEALANT ALL AROUND 2'-3" FLUSH CONCRETE WITH MIN 4" ALUMINUM TUBE CENTERED 1" x 6" DEEP REVEAL WITH 1 3/4" MIN ADJOINING PAVEMENT CONCRETE 6" NITROGEN AIR TOWER NON-SHRINK GROUT- FULL DEPTH - FOR ASSISTANCE 1/2" PRE-MOULDED SEE LIGHT POLE INSTALLATION MANUAL BOLLARD - TYP DURING BUSINESS HOURS, SEE TIRE JOINT FILLER CONCRETE CENTER EMPLOYEE AT MARKED BAY DOOR CHAMFER CURB 6" EQ 11" 12" MIN (2) 3/8" DIA PLASTIC TUBE WEEPS 5'-4" HEAVY DUTY WITH COTTON WICK - OPP SIDES 6" CONCRETE SLAB WITH PAVING ACCESS BOX - 2'-6" EQ MEDIUM BROOM FINISH PER ELECTRICAL SMOOTH FINISH EXPOSED CONCRETE - 11" ELEVATION PAVING - PER CIVIL SLOPE 2% DO NOT PATCH AND SACK - NO SPIRAL 2'-0" 2'-0" 1-1/4" CONDUIT SWEEPS 1-1/4" CONDUITS FROM SEAMS OR VERTICAL MARKINGS ALLOWED PER STRUCTURAL DRAWING SIGNAGE ON 6" WAREHOUSE BUILDING BOLLARD (SOIC) 0'-10" EQ EQ MIN 10" MIN CURB (UNO) 20'-0" CONDUIT STUBS UP MIN 17'-4" 6" ABOVE GRADE - TYP #4 CONTINUOUS CURB FIBERGLASS OR ALUMINUM STUB 6" NITROGEN AIR TOP AND BOTTOM PROFILE - (DASHED) 6'-7" LONG UNDERGROUND GAS TIRE AND POWER ROUTING - LOCATE CONDUITS TOWER - SEE A504 524 PER CIVIL CONCRETE BASE - SEE STRUCTURAL WITHIN 4" X 6" AREA PLAN INFLATION SEE ELECTRICAL SITE PER AIR TOWER MFR GROUND ROD - PER ELECTRICAL DRAWINGS FOR REINFORCING LIGHTING PLAN PARKING ELECTRICAL CONDUIT - SEE ONLY 2'-0"MIN ELECTRICAL DRAWINGS PAINT (2) COATS 2'-0" TYP SAFETY YELLOW - CENTER TEXT TO STALL LIGHT POLE LOCATION WHERE PARKING TIRE INFLATION STATION NITROGEN AIR TOWER ENLARGED DETAIL LIGHT POLE BASE AT CONCRETE ISLAND/LANDSCAPING OCCURS CLOSURE PLATE AT TOP OF POST ℄ SYM ABOUT SIGN AS NOTED BY GC PARKING STALL DEPTH PARKING STALL 3/8" x 6" STAINLESS STEEL THROUGH 1'-0" 9'-6" 9'-6" BOLT AND NUT Xref (s): ; XB2401824-00 ; excavateddropinletprotection ; filterfabricdropinletprotection ; reinforcedsiltfence ; siltfence ; stabilizedconstructionaccess 3" SCHEDULE 40 HOT DIPPED GALVANIZED STEEL PIPE SOLID 1'-6" GROUT WITH ROUNDED CONCRETE CAP - CENTER IN FOOTING Desc. 7'-0" (UNO) 4'-0" 2" SCHEDULE 40 HOT DIPPED GALVANIZED STEEL PIPE RAILS - TYP 2" x 2" x 1/8" GALVANIZED REVISIONS 1'-6" SQUARE STEEL TUBE POST 1" CONCRETE WASH Date RUBBER CART STOP - 11" No. PAVING PER CIVIL 1-1/4" HIGH - SEE SPECS 1" SLOPE WASH Designed J.J.L. Drawn J.J.L. 3'-0" Reviewed K.A.K. 2'-0" 7/17/2026, JLYNN, G:\JOBS24\18\2401824\DWG\C2401824-110.DWG.C1.100 24X36. CONCRETE Scale 1"=30' Project No. 2401824 Date 07/17/2026 AGGREGATE BASE CAD File: C2401824-110 1'-0" 1'-0" DIA Title 1'-0" DIA CONC FTG SITE DETAILS CART STORAGE SITE SIGNAGE POST Sheet No. ISSUED FOR PERMITTING C1.100 NOT RELEASED FOR CONSTRUCTION C 2026 BL COMPANIES, INC. THESE DRAWINGS SHALL NOT BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION WITHOUT THE SPECIFIC WRITTEN PERMISSION OF BL COMPANIES. Page 1098 of 1174