Southtowns Record

PB Agenda Packet 8.13.2026

Government
Town of West Seneca
Board
Planning Board
Meeting
Aug 13, 2026, 6:00 p.m.
Posted by publisher
Jul 28, 2026
Kind
Agenda packet
Topics
Water, sewer and drainage, Roads and traffic, Housing, Zoning and land use, Parks and recreation, Budget and taxes, Public safety

Original document

Same meeting

Text · page 1112 of 1174

Read the whole document on one page (all 1174 pages, each with its own heading)

Land Surveying
  142LF 24" HDPE @ 0.50%

  Environmental
  DRAINAGE PLAN LEGEND

  Architecture
  Engineering
  0.50%
  PROPERTY LINE
  LIMIT OF DISTURBANCE AND SITEWORK  619

  " HDPE @
  CONTRACT LIMIT LINE
  SAWCUT LINE  619  61

  220LF 30
  8
  STORM LINE  61
  61  8
  9  61
  8
  PROVIDE AND INSTALL TYPE C CATCH BASIN

  619
  620
  PROVIDE AND INSTALL TYPE C-L CATCH BASIN
  MH-100
  PROVIDE AND INSTALL CIRCULAR STRUCTURE  TF=619.54
  INV IN=611.78 (S)  620
  INV IN=613.27 (SE)  620
  PROVIDE AND INSTALL MANHOLE  INV OUT=611.78
  620  (NW)  620  620  355 Research Parkway
  Meriden, CT 06450
  PROVIDE AND INSTALL FOUNDATION  73LF 24" HDPE @ 0.50%  (203) 630-1406
  UNDERDRAIN/ FROST FREE FILL DRAIN
  STORM LINE W/ RIGID CLOSED CELL INSULATION  46LF 6" HDPE @ 0.50%

  APPROXIMATE LOCATION OF 4" PERFORATED
  PVC FROST FREE FILL DRAIN (TYP.). REFER TO

  62
  0
  ARCHITECTURAL DETAILS FOR EXACT LOCATION.

  618
  PROVIDE AND INSTALL 6"  1.46%  CB-204
  HDPE ROOF DRAIN @ MIN.  TF=618.19
  0.5% SLOPE (TYP.)  INV IN=611.03 (SE)
  INV OUT=611.03 (NW)

  ROOF LEADER  APPROXIMATE LOCATION OF 4" PERFORATED  7/17/2026
  INVERT= 614.10  PVC FROST FREE FILL DRAIN (TYP.). REFER TO
  ARCHITECTURAL DETAILS FOR EXACT LOCATION.  619
  PROVIDE AND INSTALL FOOTING DRAIN
  ROOF LEADER INVERT=612.41 (TYP.)  617  INV IN=611.31 (SE)
  INV IN=611.31 (SW)
  INV OUT=611.31 (NW) 61
  9

  220LF 10" HDPE @ 0.50%
  620
  DEVELOPER'S PLAN BY OTHERS

  MH-201
  TF=619.34

  COSTCO WHOLESALE
  TRENCH DRAIN-1  INV IN=611.45 (SW)
  TF=616.43

  ±18K S.F. MDO
  INV IN=611.45 (SE)
  INV OUT=612.63 (NE)

  WEST SENECA, NEW YORK
  INV OUT=611.45 (NW)
  64LF 15" HDPE @ 1.83%  INV IN=611.54 (SE)
  INV IN=611.54 (SW)

  70LF 24" HDPE @ 0.50%
  ROOF LEADER  INV OUT=611.54 (NW)
  INVERT= 614.10  29LF 10" HDPE @ 8.87%

  SLADE AVENUE
  FFE = ±620.60  45LF 10" HDPE @ 4.88%
  620
  INV IN=611.89 (SE)
  INV IN=611.89 (SW)

  191 LF 24" HDPE @ 0.50%
  ROOF LEADER  INV OUT=611.89 (NW)
  INVERT= 614.10

  158K PROTO
  FOUNDATION UNDERDRAIN
  CONNECTION
  4" PVC PIPE @ MIN. 0.50%
  SLOPE
  INV IN=612.21 (SE)
  PROVIDE AND INSTALL FOOTING DRAIN  INV IN=612.21 (SW)
  INV OUT=612.21 (NW)

  812 PARKING SPACES
  ROOF LEADER
  INVERT= 614.10  26LF 24" HDPE @ 0.50%
  45LF 10" HDPE @ 3.90%
  48LF 15" HDPE @ 2.19%
  45LF 10" HDPE @ 4.18%
  INV IN=612.34 (SE)
  SHEET 2.51  SHEET 2.52  TRENCH DRAIN-2
  INV IN=612.34 (SW)
  INV OUT=612.34 (NW)
  ROOF LEADER INVERT=613.24  TF=616.47
  INV OUT=613.47 (NE)  17LF 24" HDPE @ 0.50%
  0
  62
  DN

  MH-200
  TF=618.69
  DN  INV IN=612.43 (E)
  INV IN=612.43 (S)
  APPROXIMATE LOCATION OF 4"  619
  CAUTION

  CAUTION
  CAUTION

  CAUTION

  INV IN=612.43 (SW)
  PERFORATED PVC FROST FREE FILL DRAIN  153LF 10" HDPE @ 0.50%  INV OUT=612.43 (NW)
  (TYP.). REFER TO ARCHITECTURAL
  DETAILS FOR EXACT LOCATION.  8LF 10" HDPE @ 0.50%
  618(SW)
  CAUTION

  CAUTION

  CAUTION
  CAUTION

  CAUTION

  CAUTION

  CAUTION
  CAUTION

  CAUTION
  CAUTION

  INV IN=612.47
  PROVIDE AND INSTALL RIGID INV OUT=612.47 (N)  41LF 18" HDPE @ 0.50%
  ROOF LEADER INVERT=613.56  CLOSED CELL INSULATION (TYP.)  CB-203
  617  TF=616.57
  617  INV IN=612.63 (S)
  INV OUT=612.63 (W)
  CAUTION

  CAUTION

  CAUTION
  617
  CAUTION

  158LF 10" HDPE @ 0.50%
  0%  INV IN=612.77 (S)
  0.5
  DN

  DN

  CB-201  INV IN=612.77 (SW)
  PROVIDE AND INSTALL RIGID  @  INV OUT=612.77 (N)
  TF=616.79
  CLOSED CELL INSULATION (TYP.)  DPE
  INV IN=613.29 (SW)
  "H

  618
  619
  620

  Desc.
  INV OUT=613.29 (NE)  5
  122LF 15" HDPE @ 0.50%  F1

  Xref (s): ; XY240182401 ; XC2401824-10 ; XB2401824-00 ; XC2401824-20 ; XC2401824-21 ; XO2401824-01 ; KM2401824-KeyMap
  SHEET 2.53  100LF 15" HDPE @ 0.50%  81LF 12" HDPE @ 0.50%
  SHEET 2.54  617  L
  52
  9.43%
  86LF 12" HDPE @ 1.32%  66LF 12" HDPE @ 0.50%  51LF 12" HDPE @ 0.50%
  8

  REVISIONS
  62  0  0  61
  0  62  62

  Date
  PROVIDE AND INSTALL RIGID
  KEY MAP  CLOSED CELL INSULATION (TYP.)

  No.
  CB-103  CB-101  CB-200A  CB-200B  CB-202
  CB-102  TF=617.49
  TF=619.61  TF=620.10  TF=620.00  TF=619.76  TF=617.31
  INV IN=615.59 (NE)  INV OUT=616.50 (SW)  INV OUT=614.76 (NE)  INV IN=613.62 (SW)  INV IN=613.03 (SW)
  INV IN=616.09 (NE)  INV OUT=613.62 (NE)
  INV OUT=615.59 (SW)  INV OUT=616.09 (SW)  INV OUT=613.03 (N)  Designed  J.J.L.
  PROVIDE AND INSTALL PAVEMENT  Drawn  J.J.L.
  UNDERDRAINS AT CATCH BASIN (TYP.)
7/17/2026, JLYNN, G:\JOBS24\18\2401824\DWG\C2401824-25.DWG.C2.54 24X36 30SC.

  Reviewed  K.A.K.
  Scale  1"=30'
  Project No.  2401824
  Date  07/17/2026
  CAD File:
  C2401824-25

  Title

  DRAINAGE PLAN

  Sheet No.

  C2.54
  GRAPHIC SCALE

  ISSUED FOR PERMITTING  30  15  0  30

  NOT RELEASED FOR CONSTRUCTION  SCALE IN FEET

  C 2026 BL COMPANIES, INC. THESE DRAWINGS SHALL NOT BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION WITHOUT THE SPECIFIC WRITTEN PERMISSION OF BL COMPANIES.

  Page 1112 of 1174