Text · page 1114 of 1174
Read the whole document on one page (all 1174 pages, each with its own heading)
Land Surveying Environmental Architecture Engineering EXTERIOR GRADE PER CIVIL FOOTING PER STRUCTURAL FROST LINE PER FINISHED FLOOR GEOTECHNICAL - FOOTING MAY BE LOWER EXTERIOR WALL PAVING, PER CIVIL -OR- LANDSCAPING 355 Research Parkway Meriden, CT 06450 AGGREGATE BASE (203) 630-1406 NOTCH FOOTING PIPE INVERT PER WHERE REQUIRED CIVIL - 2% MINIMUM DAMPPROOFING CAST IRON FITTING CAST IRON PIPE DRAIN ROCK ISOMETRIC MINIMUM 6" COVER ABOVE PIPE SCALE: NTS GRID 1'-0" MIN COLUMN PER STRUCTURAL / METAL BUILDING SUPPLIER GEOTEXTILE FABRIC SURROUND - MIN EXTEND UP WALL 2" COLUMN PLINTH EXTERIOR WALL PER PLAN 7/17/2026 BELOW FLOOR MAIN FRAME COLUMNS COLUMN FOOTING BELOW MINIMUM 4" DIA RIGID NOTE: 6" MIN PVC PERFORATED CONNECT TO STORM SYSTEM FOOTING DRAIN - 6'-0" MIN AT COLUMN INSTALL WITH HOLES DOWN FOOTING BELOW WALL FOOTING BELOW FOOTING DRAIN NOTE: RUN RAIN LEADER STRIGHT FROM ROOF DRAIN WITHOUT OFFSETS TO WALL - LOCATE TO MISS PLINTH STORM SEWER INLET NOTCH FOOTING BELOW AS REQUIRED PAVEMENT - SLOPE PER GRADING PLAN COSTCO WHOLESALE AGGREGATE BASE COURSE WEST SENECA, NEW YORK WALL FOOTING BELOW 1'-0" 1'-1" PAVEMENT UNDERDRAIN - PLAN 4" MINIMUM PENETRATION INTO SUBGRADE 4" DIAMETER SLOPE SLOPE SLADE AVENUE COLUMN BEYOND EXTERIOR WALL PER PLAN PERFORATED PVC PIPE - PLACED WITH PERFORATIONS DOWN PAVEMENT OR INSULATION ON RAIN LEADER LANDSCAPING - SEE PLAN 6" PVC WRAP TO 8'-0" AFF WHERE EXPOSED SLOPE 2% MINIMUM AASHTO #57 STONE - COMPACTED TO A POINT OF NON-MOVEMENT 1'-0" NOTE: VARIES - SEE CIVIL DRAWINGS - BENEATH THE COMPACTING EQUIPMENT BLOCK-OUT SLAB 2" LARGER THAN MINIMUM 1" RAIN LEADER SIZE - PROVIDE 4" 4" SEALANT AND BACK ROD ALL AROUND 0'-0" FIN FLR MIRAFI 140NS NON-WOVEN SLOPE GEOTEXTILE OR EQUIVALENT - 2" EXTERIOR GRADE . OVERLAP MINIMUM OF 12" ON TOP CONCRETE FOOTING - VERIFY . FOOTING DEPTH / THICKNESS FROST DEPTH WITH STRUCTURAL DRAWINGS PER GEOTECHNICAL NOTCH FOOTING AT RAIN LEADER WHERE REQUIRED BOTTOM OF FOOTING MAY BE LOWER THAN FROST - . CONCRETE FOOTING SEE STRUCT DRAWINGS AT COLUMN BEYOND 2% MINIMUM PAVEMENT UNDERDRAIN DETAIL MINIMUM 6" COVER ABOVE PIPE SLOPE RAIN LEADER UNDER FOOTING INVERT NOTE: PAVEMENT UNDERDRAINS SHALL EXTEND OUT A MINIMUM SECTION ELEVATION OF 10 FEET FROM ALL SIDES OF INLETS BELOW PAVEMENT SECTION (+/-) 5'-0" BY PLUMBING PER CIVIL RAIN LEADER INVERT ELEVATION PAVEMENT UNDERDRAIN AT INLETS Xref (s): ; XB2401824-00 ; excavateddropinletprotection ; filterfabricdropinletprotection ; reinforcedsiltfence ; siltfence ; stabilizedconstructionaccess Desc. CONCRETE SLAB REVISIONS DENSOBAND WAREHOUSE WALL PER PLAN Date PAVING SLOPE 2% MAX No. Designed J.J.L. Drawn J.J.L. Reviewed K.A.K. UNDER-SLAB OVER STRUCT FILL 7/17/2026, JLYNN, G:\JOBS24\18\2401824\DWG\C2401824-110.DWG.C2.101 24X36. EXCAVATION PER GEOTECH Scale 1"=30' STRUCTURAL FILL Project No. 2401824 (AS REQUIRED) Date 07/17/2026 CAD File: C2401824-110 Title GRADING AND DRAIN TILE LOWER THAN FOOTING, CONNECT TO STORM SEWER DRAINAGE DETAILS FOOTING OVER EXCAVATION/ STRUCTURAL FILL (AS REQUIRED) Sheet No. WALKWAY AT PARKING ISSUED FOR PERMITTING C2.101 NOT RELEASED FOR CONSTRUCTION C 2026 BL COMPANIES, INC. THESE DRAWINGS SHALL NOT BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION WITHOUT THE SPECIFIC WRITTEN PERMISSION OF BL COMPANIES. Page 1114 of 1174