Text · page 1121 of 1174
Read the whole document on one page (all 1174 pages, each with its own heading)
Land Surveying Environmental SITE UTILITIES LEGEND PROVIDE AND INSTALL FIRE HYDRANT ASSEMBLY, Architecture Engineering 356LF 8" PVC @ 1.83% 6" DIP HYDRANT LATERAL, GATE VALVE, THRUST BLOCKS, AND BOLLARDS AS REQUIRED BY LOCAL UTILITY PROVIDER AND/OR FIRE MARSHALL (TYP.) PROPERTY LINE SMH-5 SMH-6 PROVIDE AND INSTALL FIRE HYDRANT ASSEMBLY, LIMIT OF DISTURBANCE AND SITEWORK TF=619.44 TF=619.02 6" DIP HYDRANT LATERAL, GATE VALVE, THRUST NW INV IN=611.84 (SE) BLOCKS, AND BOLLARDS AS REQUIRED BY LOCAL INV CONTRACT LIMIT LINE INV IN=610.80 (SW) INV IN=609.70 (SW) RIM 608.1 INV OUT=610.70 (NE) UTILITY PROVIDER AND/OR FIRE MARSHALL (TYP.) SAWCUT LINE INV OUT=609.60 (N) SAN 615.15 7 E E ELECTRIC LINE MH 12 G G GAS LINE W W WATER LINE 214LF 8" PVC @ 0.50% S S SANITARY SEWER LINE 200LF 8" PVC @ 0.50% PROVIDE AND INSTALL 10"X6"X10" DIP T T TELECOMMUNICATIONS LINE PROVIDE AND INSTALL 10"X6"X10" DIP TEE FITTING WITH RESTRAINED JOINTS TEE FITTING WITH RESTRAINED JOINTS AND/OR THRUST BLOCK (TYP.) ETC ELECTRIC AND TELECOMMUNICATIONS LINE AND/OR THRUST BLOCK (TYP.) 355 Research Parkway WV WV Meriden, CT 06450 OH OH OVERHEAD ELECTRIC LINE 74LF 6" HPP @ 2.00% (203) 630-1406 STORM LINE PROVIDE AND INSTALL EXTERIOR GAS SERVICE PIPING, SIZE AND TYPE OF PIPE TO BE DETERMINED PROVIDE AND INSTALL BENDS, RESTRAINTS BY PROVIDER, COORDINATE WITH UTILITY PROVIDER AND THRUST BLOCK OER LOCAL UTILITY PROVIDER (TYP.) PROVIDE AND INSTALL GREASE INTERCEPTOR 1 PROVIDE AND INSTALL TRANSFORMER PAD TF=616.65 AND BOLLARDS. COORDINATE WITH INV IN=613.49 (SE) ELECTRIC UTILITY PROVIDER. 7/17/2026 INV OUT=612.99 (NW) 6LF 6" HPP @ 2.00% PROVIDE AND INSTALL (2) 6" PVC SCH BLDG INV OUT=613.60 (NW) 80 CONDUITS ENCASED IN CONCRETE GAS SERVICE CONNECTION TO BUILDING. AND WITH PULL STRINGS FOR PROVIDE AND INSTALL EXTERIOR GAS METER, ELECTRICAL SERVICE TO WAREHOUSE COORDINATE WITH UTILITY PROVIDER PROVIDE AND INSTALL ELECTRIC TRAFFIC RATED HANDHOLE PER UTILITY PROVIDER SPECIFICATIONS (TYP.) PROVIDE AND INSTALL SAND SEPARATOR TF=616.95 INV IN=614.04 (SW) INV OUT=614.24 (NE) COSTCO WHOLESALE PROVIDE AND INSTALL ELECTRIC SECONDARY ±18K S.F. MDO WV CONDUITS FROM TRANSFORMER TO BUILDING, WEST SENECA, NEW YORK NUMBER, TYPE, AND SIZE PER ELECTRIC PLANS PROVIDE AND INSTALL 10"X10"X10" DIP TEE FITTING WITH RESTRAINED JOINTS SLADE AVENUE BLDG INV OUT=614.10 (NE) AND/OR THRUST BLOCK 9LF 6" HPP @ 2.00% SMH-7 TF=619.85 INV IN=614.86 (SW) 4" DIP DOMESTIC WATER SERVICE CONNECTION TO BUILDING, INV OUT=614.76 (NW) PROVIDE AND INSTALL METER PER UTILITY PROVIDER REQUIREMENTS FFE = ±620.60 10" DIP FIRE PROTECTION WATER SERVICE CONNECTION TO BUILDING. PROVIDE AND INSTALL METER AND EQUIPMENT PER UTILITY PROVIDER REQUIREMENTS PROVIDE AND INSTALL GATE VALVE, VALVE BOX, AND COVER (TYP.) 158K PROTO 812 PARKING SPACES SHEET 3.01 SHEET 3.02 PROVIDE AND INSTALL ELECTRIC TRAFFIC RATED HANDHOLE PER UTILITY PROVIDER SPECIFICATIONS (TYP.) DN APPROXIMATE LOCATION OF RELOCATED GAS LINE. CONTRACTOR TO COORDINATE ALL UTILITY WORK WITH DEVELOPER AND UTILITY PROVIDER, CONTRACTOR TO VERIFY EXISTING LOCATION, PRESSURE, AND SIZE PRIOR TO CONSTRUCTION, RELOCATION IN ACCORDANCE WITH DN UTILITY PROVIDER REQUIREMENTS. CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION CAUTION Xref (s): ; XY240182401 ; XC2401824-10 ; XB2401824-00 ; XC2401824-20 ; XC2401824-21 ; XC2401824-30 ; XO2401824-01 ; KM2401824-KeyMap CAUTION CAUTION DN DN Desc. SHEET 3.03 PROVIDE AND INSTALL BENDS, RESTRAINTS SHEET 3.04 AND THRUST BLOCK OER LOCAL UTILITY PROVIDER (TYP.) REVISIONS CONNECT TO EXISTING GAS LINE. CONTRACTOR TO WV COORDINATE ALL UTILITY WORK WITH DEVELOPER Date AND UTILITY PROVIDER, CONTRACTOR TO VERIFY KEY MAP BURIAL DEPTH AND SIZE PRIOR TO CONSTRUCTION, RELOCATION IN ACCORDANCE WITH UTILITY No. PROVIDER REQUIREMENTS. PROVIDE AND INSTALL 10" DIP FIRE PROTECTION WATER LOOP, APPROXIMATE LOCATION, COORDINATE WITH FIRE PROVIDE AND INSTALL 10"X6"X10" DIP TEE FITTING WITH PROTECTION ENGINEER AND UTILITY PROVIDER (TYP.) RESTRAINED JOINTS AND/OR THRUST BLOCK (TYP.) Designed J.J.L. PROVIDE AND INSTALL 4" DOMESTIC PROVIDE AND INSTALL (2) 6" PVC SCH 80 CONDUITS ENCASED IN CONCRETE AND WITH PULL STRINGS Drawn J.J.L. WATER SERVICE (TYP.) PROVIDE AND INSTALL FIRE HYDRANT ASSEMBLY, 7/17/2026, JLYNN, G:\JOBS24\18\2401824\DWG\C2401824-30.DWG.C3.04 24X36 30SC. FOR ELECTRICAL SERVICE TO WAREHOUSE Reviewed K.A.K. 6" DIP HYDRANT LATERAL, GATE VALVE, THRUST BLOCKS, AND BOLLARDS AS REQUIRED BY LOCAL Scale 1"=30' UTILITY PROVIDER AND/OR FIRE MARSHALL (TYP.) Project No. 2401824 Date 07/17/2026 PROVIDE AND INSTALL RIGID CAD File: METAL CONDUIT DOWN POLE TO C2401824-30 SUBSURFACE CONNECTION FOR PRIMARY ELECTRICAL SERVICES Title SITE UTILITY PLAN Sheet No. C3.04 GRAPHIC SCALE ISSUED FOR PERMITTING 30 15 0 30 NOT RELEASED FOR CONSTRUCTION SCALE IN FEET C 2026 BL COMPANIES, INC. THESE DRAWINGS SHALL NOT BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION WITHOUT THE SPECIFIC WRITTEN PERMISSION OF BL COMPANIES. Page 1121 of 1174