Text · page 1170 of 1174
Read the whole document on one page (all 1174 pages, each with its own heading)
Profile Report Engineering Profile - CB-117 TO CB-115 (C-DAT-2401824-StormCAD-2026-07-14.stsw) CB-117 Rim: 617.17 ft Invert: 609.67 ft CB-116 Rim: 617.32 ft Invert: 609.33 ft CB-115 Rim: 617.44 ft Invert: 607.50 ft 620.00 Elevation (ft) 615.00 610.00 P43: 74.0 ft @ 0.005 ft/ft 605.00 Circle - 18.0 in HDPE P42: 67.0 ft @ 0.005 ft/ft -0+50 0+00 0+50 1+00 1+50 Circle - 18.0 in HDPE Station (ft) StormCAD C-DAT-2401824-StormCAD-2026-07-14.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.04.00.158] 7/16/2026 76 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203-755- Page 1 of 1 1666 Page 1170 of 1174