Text · page 28 of 1174
Read the whole document on one page (all 1174 pages, each with its own heading)
NOT FOR CONSTRUCTION 75 LF 12" SICPP ST @ 1.00% MIN. 599 600 601 MATCH TO INSET ST 300 Pearl Street, Suite 130 Buffalo, NY 14202 END SECTION INV=583.66 716-551-6281 12 LF 12" SICPP @ 1.00% 599 ST 600 labellapc.com 600 599 60 1 C0 598 ST UD UD UD UD UD UD UD UD UD UD UD UD D 598 600.14 599 600 NEW BIORETENTION 600 AREA #1 (± 350 SF) ST-4.0 599 600 ST 75 LF 12" SICPP 4' DIA. MH ST-4.1 597 597 598 599 ST 598 RIM=600.25 599 @ 1.00% MIN. 599 600 24"x24" CB N INV=594.36 600 600 RIM=599.00 W INV=594.46 601 N INV=594.58 S INV=595.25 6" SICPP @ ST 1.00% MIN. ST EXP: EXP: ST N CERTIFICATE OF AUTHORIZATION NUMBER: 2 INSET 60 0 PROFESSIONAL ENGINEERING: 0021272 LAND SURVEYING: 0021271 C301 SCALE: 1"=20' GEOLOGICAL: 0021659 ST NEW PRIVATE FIRE HYDRANT It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 FS ST-3.4 Sec. 7307, for any person, unless acting under the direction of a licensed ST 24"x24" CB architect, professional engineer, or land surveyor, to alter an item in any ST RIM=599.65 way. If an item bearing the seal of an architect, engineer, or land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to S INV=597.58 the item their seal and notation "altered by" followed by their signature and FS date of such alteration, and a specific description of the alteration. ST ST © 2024 2026 LaBella Associates FS 600 ST ST NEW 6" FIRE SERVICE 600 600 (AFTER BACKFLOW PREVENTOR) HOME LEASING 598 FS 598 599 599 ST 75 S CLINTON AVE SUITE 700, 600 ST ROCHESTER, NEW YORK 14604 150 LF 12" SICPP @ 1.00% FS ST 600 ST 595 596 FS 597 ST 598 ST FS NEW BACKFLOW PREVENTOR (IN FS ST MECHANICAL ROOM) FOR COMBINED ST SERVICE. DOMESTIC SERVICE WILL BE PROPOSED METERED AFTER THE BACKFLOW. 600 600 W 3-STORY C0 ST BUILDING C0 W ± 25,000 SF FOOTPRINT ST-3.3 ST 24"x24" CB RIM=599.75 FFE=600.75' 6" SICPP @ N INV=596.08 WEST SENECA APARTMENTS 599 ST 599 1.00% MIN. SW INV=596.08 2544 CLINTON ST, W WEST SENECA, NY 14224 595 596 597 598 NEW 6" PVC SDR-21 C0 ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST SA SANITARY LATERAL 600 599 600 W SA C0 ST CONNECT INTO 600 600 EXISTING SAN CO 600 ST SANITARY MAIN SA SA SA TYP. SA C0 SA W 60 SA 0 S SA SA SA SA SA SA SA SA SA SA SA SA SA SA SA SA SA C0 SA SA ST 4' DIA. SAN MH SA SA SA SA SA SA SA SAN CO 600 RIM=600.15 NEW 6" PVC SDR-21 102 LF 12" TYP. SAN CO E INV=589.50 SICPP @ 1.00% SA SANITARY LATERAL ST TYP. NO: DATE: DESCRIPTION: W INV=589.40 70 LF 6" SICPP W \\cash.lab\P\GLOBAL\Projects\Home Leasing Services\2241067 - Affordable Housing West Seneca\06_Drawings\Civil\C300 UTILITY PLAN.dwg @ 1.00% MIN. Revisions ST SA ST-3.0 PROJECT NUMBER: ST ST-2.0 4' DIA. MH 2241067 SA W 4' DIA. MH RIM=599.33 RIM=599.29 N INV=593.25 599 599 ST W INV=592.12 S INV=592.25 DRAWN BY: 600 E INV=591.25 EMM / SCB SA W INV=591.25 ST 30 LF 12" SICPP REVIEWED BY: SRV / DPB W D D 50 5LF 99 12" SICPP @ 5.00% SA @ 5.00% 599 ISSUED FOR: ST ST-2.2 SITE PLAN APPROVAL 59 24"x24" CB 9 SA ST-1.1 ST ST RIM=598.62 W 4' DIA. MH DATE: E INV=596.12 599 ST 85 LF 12" SICPP 4/20/2026 RIM=599.08 E INV=591.25 @ 2.00% SA SAN CO ST ST ST ST ST ST ST ST TYP. W INV=591.25 35 LF 12" SICPP DRAWING NAME: C0 D D ST ST ST ST ST ST ST @ 3.00% W ST-3.2 SA 120 LF 8" SICPP ST-2.1 ST-3.1 END SECTION ST-1.0 24"x24" CB @ 1.00% 24"x24" CB 24"x24" CB NEW 6" COMBINED ADS STORMTECH CHAMBER RIM=598.50 INV=589.75 RIM=598.87 CONTECH CASCADE CS4 WQU RIM=598.89 599 SYSTEM SC-3500 WATER SERVICE NE INV=595.00 SA W INV=593.62 RIM=599.00 N INV=593.30 NE INV=593.62 E INV=591.15 (100 CHAMBERS) W INV=593.30 599 W INV=595.00 W NEW 4" PVC SDR-21 W INV=591.15 NEW PRIVATE INV=591.25 UTILITY PLAN SA SANITARY LATERAL FIRE HYDRANT MATCH TO SHEET: C302 SA W FS 600 DRAWING NUMBER: SA W C0 600 UTILITY PLAN NOTES: 4/20/2026 1:18:02 PM 1. A MINIMUM OF 10 FEET OF HORIZONTAL AND 18" OF VERTICAL SEPARATION N MUST BE MAINTAINED BETWEEN ALL SANITARY AND WATER SERVICES 1 UTILITY PLAN 0' 20' 40' 60' 2. THE ERIE COUNTY WATER AUTHORITY IS TO BE NOTIFIED A MINIMUM OF C301 48-HOURS PRIOR TO STARTING THE CONNECTION TO THE NEW WATER SERVICE C301 SCALE: 1" = 20' 3. SELECT BACKFILL IS REQUIRED FOR ALL UTILITIES (GAS, WATER, STORM, SANITARY) THAT CROSS THROUGH ANY PAVEMENT AREA Page 28 of 1174