WEST SENECA - PRE DEVELOPMENT
D_App D_Pre-Development Model_REV 1  NY-West Seneca 24-hr S1 1-yr Rainfall=1.82"
Prepared by Labella Associates  Printed 7/26/2026
HydroCAD® 10.20-6a s/n 09581 © 2024 HydroCAD Software Solutions LLC  Page 10

  Summary for Subcatchment ES-3: OFF-SITE DRAINAGE

Runoff  =  0.93 cfs @ 12.89 hrs, Volume=  0.175 af, Depth= 0.42"
  Routed to Reach AP-1 : Cayuga Creek

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs
NY-West Seneca 24-hr S1 1-yr Rainfall=1.82"

  Area (sf)  CN  Description
  2,218  80  >75% Grass cover, Good, HSG D
  570  98  Paved parking, HSG D
  215,230  79  Woods, Fair, HSG D
  218,018  79  Weighted Average
  217,448  99.74% Pervious Area
  570  0.26% Impervious Area

  Tc Length Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  34.2  100 0.0100  0.05  Sheet Flow, 100'
  Woods: Light underbrush n= 0.400 P2= 2.20"
  24.4  732 0.0100  0.50  Shallow Concentrated Flow, REMAINING
  Woodland Kv= 5.0 fps
  58.6  832 Total

  Subcatchment ES-3: OFF-SITE DRAINAGE
  Hydrograph

  Runoff
  1
  0.93 cfs

  NY-West Seneca 24-hr S1 1-yr
  Rainfall=1.82"
  Runoff Area=218,018 sf
  Runoff Volume=0.175 af
  Runoff Depth=0.42"
  Flow (cfs)

  Flow Length=832'
  Slope=0.0100 '/'
  Tc=58.6 min
  CN=79

  0
  0  2 4  6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72
  Time (hours)

  Page 453 of 1174