Southtowns Record

PB Agenda Packet 8.13.2026

Government
Town of West Seneca
Board
Planning Board
Meeting
Aug 13, 2026, 6:00 p.m.
Posted by publisher
Jul 28, 2026
Kind
Agenda packet
Topics
Water, sewer and drainage, Roads and traffic, Housing, Zoning and land use, Parks and recreation, Budget and taxes, Public safety

Original document

Same meeting

Text · page 487 of 1174

Read the whole document on one page (all 1174 pages, each with its own heading)

WEST SENECA - POST DEVELOPMENT
E_App E_Post-Development Model_REV 2  NY-West Seneca 24-hr S1 1-yr Rainfall=1.82"
Prepared by Labella Associates  Printed 7/26/2026
HydroCAD® 10.20-6a s/n 09581 © 2024 HydroCAD Software Solutions LLC  Page 20

  Summary for Reach 8R: 15" Pipe

[52] Hint: Inlet/Outlet conditions not evaluated

Inflow Area =  6.227 ac, 0.63% Impervious, Inflow Depth = 0.43" for 1-yr event
Inflow  =  1.10 cfs @ 12.82 hrs, Volume=  0.222 af
Outflow  =  1.10 cfs @ 12.84 hrs, Volume=  0.222 af, Atten= 0%, Lag= 1.1 min
  Routed to Reach DP-1 : Design Point
Overflow =  0.00 cfs @ 0.00 hrs, Volume=  0.000 af
  Routed to Reach DP-1 : Design Point

Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs
Max. Velocity= 3.87 fps, Min. Travel Time= 1.5 min
Avg. Velocity = 1.88 fps, Avg. Travel Time= 3.1 min

Peak Storage= 100 cf @ 12.84 hrs
Average Depth at Peak Storage= 0.35' , Surface Width= 1.13'
Defined Flood Depth= 598.00' Flow Area= 100.4 sf, Capacity= -12,672.78 cfs
Bank-Full Depth= 1.25' Flow Area= 1.2 sf, Capacity= 6.33 cfs
Any excess flow will be diverted to the secondary overflow

15.0" Round Pipe
n= 0.013 Corrugated PE, smooth interior
Length= 350.0' Slope= 0.0096 '/'
Inlet Invert= 591.85', Outlet Invert= 588.49'

  Page 487 of 1174