WEST SENECA - POST DEVELOPMENT
E_App E_Post-Development Model_REV 2 NY-West Seneca 24-hr S1 100-yr Rainfall=5.22"
Prepared by Labella Associates  Printed 7/26/2026
HydroCAD® 10.20-6a s/n 09581 © 2024 HydroCAD Software Solutions LLC  Page 76

  Summary for Reach 9R: East Swale

Inflow Area =  6.227 ac, 0.63% Impervious, Inflow Depth = 3.01" for 100-yr event
Inflow  =  9.64 cfs @ 12.73 hrs, Volume=  1.562 af
Outflow  =  9.63 cfs @ 12.74 hrs, Volume=  1.562 af, Atten= 0%, Lag= 0.4 min
  Routed to Reach 8R : 15" Pipe

Routing by Dyn-Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs
Max. Velocity= 3.79 fps, Min. Travel Time= 2.0 min
Avg. Velocity = 1.50 fps, Avg. Travel Time= 5.1 min

Peak Storage= 1,167 cf @ 12.74 hrs
Average Depth at Peak Storage= 0.64' , Surface Width= 5.87'
Bank-Full Depth= 3.00' Flow Area= 33.0 sf, Capacity= 303.17 cfs

2.00' x 3.00' deep channel, n= 0.022 Earth, clean & straight
Side Slope Z-value= 3.0 '/' Top Width= 20.00'
Length= 460.0' Slope= 0.0101 '/'
Inlet Invert= 599.00', Outlet Invert= 594.35'

  Reach 9R: East Swale
  Hydrograph

  Inflow
  9.64 cfs  Outflow
  10  9.63 cfs
  Inflow Area=6.227 ac
  9
  Avg. Flow Depth=0.64'
  8
  Max Vel=3.79 fps
  7
  n=0.022
  Flow (cfs)

  6
  L=460.0'
  5
  S=0.0101 '/'
  4
  Capacity=303.17 cfs
  3

  2

  1

  0
  0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72
  Time (hours)

  Page 543 of 1174