Text · page 548 of 1174
Read the whole document on one page (all 1174 pages, each with its own heading)
WEST SENECA - POST DEVELOPMENT E_App E_Post-Development Model_REV 2 NY-West Seneca 24-hr S1 100-yr Rainfall=5.22" Prepared by Labella Associates Printed 7/26/2026 HydroCAD® 10.20-6a s/n 09581 © 2024 HydroCAD Software Solutions LLC Page 81 Primary OutFlow Max=0.02 cfs @ 12.26 hrs HW=599.07' TW=0.00' (Dynamic Tailwater) 1=Exfiltration Through Media (Exfiltration Controls 0.02 cfs) Secondary OutFlow Max=0.44 cfs @ 12.26 hrs HW=599.07' TW=0.00' (Dynamic Tailwater) 3=Culvert (Passes 0.44 cfs of 1.54 cfs potential flow) 2=Overflow Grate (Weir Controls 0.44 cfs @ 0.84 fps) Tertiary OutFlow Max=0.00 cfs @ 0.00 hrs HW=594.42' TW=0.00' (Dynamic Tailwater) 4=Emergency Overflow Weir ( Controls 0.00 cfs) Pond BIO-1A: Filtration Bioretention Hydrograph Inflow 1.29 cfs Outflow Inflow Area=0.232 ac Primary Secondary Tertiary Peak Elev=599.07' Storage=1,508 cf 1 Flow (cfs) 0.46 cfs 0.45 cfs 0.02 cfs 0.00 cfs 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) Page 548 of 1174