through a 48 inch outlet pipe that connects to the existing storm sewer outlet system and ultimately
discharges to Cazenovia Creek. The stormwater management facilities have been designed to satisfy the
requirements of both the Town of West Seneca and the NYSDEC. The overall stormwater management
system, including water quality treatment and peak flow control, has been designed in accordance with
Chapters 4 and 9 of the NYSDEC Stormwater Management Design Manual.

Wet Pond Summary:
Top of basin elevation = 614.50
Permanent pool elevation = 607.80
Bottom of basin elevation = 601.80
100-year storm storage volume = 283,293 cf @ 612.22

Water Quality Summary:
WQv req’d = 46,210 cf (1.061 ac-ft)
RRv min. req’d = 0 cf (0 ac-ft)
WQv provided – Wet Pond = 46,210 cf (1.061 ac-ft)
WQv provided – 46,210 cf = WQv provided = 46,210 cf

Note: Since the proposed redevelopment results in a net decrease in impervious area, no Runoff Reduction
Volume (RRv) is required. All new impervious surfaces associated with the project are classified as
disturbed impervious areas. The proposed wet pond has been designed to provide stormwater treatment for
the ultimate full buildout condition of the site.

Total Runoff Summary:
Event  Ex. Runoff (cfs)  Pro. Runoff (cfs)  Result (cfs)
1-year  103.89  38.71  -65.18
10-year  184.66  87.97  -96.69
25-year  229.09  109.83  -119.26
100-year  317.14  141.36  -175.78

West Seneca Exchange
07/20/2026
3 of 3

  Page 676 of 1174