Text · page 717 of 1174
Read the whole document on one page (all 1174 pages, each with its own heading)
24-4113 WEST SENECA EXCHANGE EXISTING Type II 24-hr 10-Year Rainfall=3.14" Prepared by Carmina Wood Design Printed 7/13/2026 HydroCAD® 10.20-7a s/n 05019 © 2025 HydroCAD Software Solutions LLC Page 20 Summary for Link 4L: TOTAL EXISTING Inflow Area = 55.600 ac, 85.88% Impervious, Inflow Depth = 2.69" for 10-Year event Inflow = 184.66 cfs @ 12.04 hrs, Volume= 12.453 af Primary = 184.66 cfs @ 12.04 hrs, Volume= 12.453 af, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-60.00 hrs, dt= 0.01 hrs Link 4L: TOTAL EXISTING Hydrograph Inflow 184.66 cfs Primary 200 184.66 cfs 190 180 Inflow Area=55.600 ac 170 160 150 140 130 120 Flow (cfs) 110 100 90 80 70 60 50 40 30 20 10 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 Time (hours) Page 717 of 1174