Text · page 742 of 1174
Read the whole document on one page (all 1174 pages, each with its own heading)
24-4113 WEST SENECA EXCAHNGE PROPOSED Prepared by Carmina Wood Design Printed 7/13/2026 HydroCAD® 10.20-7a s/n 05019 © 2025 HydroCAD Software Solutions LLC Page 7 Pipe Listing (selected nodes) Line# Node In-Invert Out-Invert Length Slope n Width Diam/Height Inside-Fill Node Number (feet) (feet) (feet) (ft/ft) (inches) (inches) (inches) Name 1 1S 0.00 0.00 950.0 0.0080 0.013 0.0 18.0 0.0 2 6S 0.00 0.00 580.0 0.0040 0.025 0.0 36.0 0.0 3 12S 0.00 0.00 60.0 0.0025 0.013 0.0 12.0 0.0 4 13S 0.00 0.00 60.0 0.0025 0.013 0.0 12.0 0.0 5 14S 0.00 0.00 700.0 0.0050 0.013 0.0 24.0 0.0 6 16P 603.56 601.35 641.0 0.0034 0.013 58.0 94.0 0.0 7 18P 607.95 604.56 685.0 0.0049 0.013 0.0 48.0 0.0 Page 742 of 1174