24-4113 WEST SENECA EXCAHNGE NY-WestSeneca_NOAA14 24-hr S1 1-yr Rainfall=1.87"
Prepared by Carmina Wood Design  Printed 7/13/2026
HydroCAD® 10.20-7a s/n 05019 © 2025 HydroCAD Software Solutions LLC  Page 12

  Summary for Subcatchment 12S: Slade Ave

[49] Hint: Tc<2dt may require smaller dt

Runoff  =  1.33 cfs @ 11.99 hrs, Volume=  0.062 af, Depth= 1.65"
  Routed to Pond 18P : POND

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-150.00 hrs, dt= 0.01 hrs
NY-WestSeneca_NOAA14 24-hr S1 1-yr Rainfall=1.87"

  Area (ac)  CN  Description
  0.450  98  Paved parking, HSG D
  0.450  100.00% Impervious Area

  Tc Length Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  0.5  30 0.0200  0.96  Sheet Flow, pavement
  Smooth surfaces n= 0.011 P2= 2.50"
  0.4  60 0.0025  2.27 1.78 Pipe Channel, 12" pipe
  12.0" Round Area= 0.8 sf Perim= 3.1' r= 0.25'
  n= 0.013 Corrugated PE, smooth interior
  0.9  90 Total

  Subcatchment 12S: Slade Ave
  Hydrograph

  Runoff
  1.33 cfs
  NY-WestSeneca_NOAA14 24-hr S1 1-yr
  Rainfall=1.87"
  Runoff Area=0.450 ac
  Runoff Volume=0.062 af
  1  Runoff Depth=1.65"
  Flow Length=90'
  Tc=0.9 min
  Flow (cfs)

  CN=98

  0
  0  10  20  30  40  50  60  70  80  90  100  110  120  130  140  150
  Time (hours)

  Page 747 of 1174