24-4113 WEST SENECA EXCAHNG NY-WestSeneca_NOAA14 24-hr S1 100-yr Rainfall=5.20"
Prepared by Carmina Wood Design  Printed 7/13/2026
HydroCAD® 10.20-7a s/n 05019 © 2025 HydroCAD Software Solutions LLC  Page 51

  Summary for Subcatchment 1S: Proposed - West

[47] Hint: Peak is 1492% of capacity of segment #2

Runoff  =  140.14 cfs @ 12.02 hrs, Volume=  7.035 af, Depth= 4.39"
  Routed to Pond 18P : POND

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-150.00 hrs, dt= 0.01 hrs
NY-WestSeneca_NOAA14 24-hr S1 100-yr Rainfall=5.20"

  Area (ac)  CN  Description
  5.060  80  >75% Grass cover, Good, HSG D
  4.110  98  Roofs, HSG D
  10.040  98  Paved parking, HSG D
  19.210  93  Weighted Average
  5.060  26.34% Pervious Area
  14.150  73.66% Impervious Area

  Tc Length Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  1.8  100 0.0100  0.92  Sheet Flow, pavement
  Smooth surfaces n= 0.011 P2= 2.50"
  3.0  950 0.0080  5.32 9.40 Pipe Channel, 18" PIPE
  18.0" Round Area= 1.8 sf Perim= 4.7' r= 0.38'
  n= 0.013 Corrugated PE, smooth interior
  4.8 1,050 Total

  Subcatchment 1S: Proposed - West
  Hydrograph

  Runoff
  150  140.14 cfs
  140  NY-WestSeneca_NOAA14 24-hr S1 100-yr
  Rainfall=5.20"
  130
  Runoff Area=19.210 ac
  120  Runoff Volume=7.035 af
  110  Runoff Depth=4.39"
  Flow Length=1,050'
  100
  Tc=4.8 min
  90  CN=93
  Flow (cfs)

  80
  70
  60
  50

  40
  30

  20
  10
  0
  0  10  20  30  40  50  60  70  80  90  100  110  120  130  140  150
  Time (hours)