WATER QUALITY REQUIRED FOR PROPOSED DEVELOPMENT AREA  Area, Acres = 53
(Note: Reference Chap. 9 NYSDEC Stormwater Design Manual)

"Redevelopment Activity", Acres = 47.75  "New development", Acres = 5.25
(existing, disturbed impervious area)

Total proposed impervious, Acres = 47.00  Adjusted impervious, Acres = 11.19
"New" impervious, Acres =  -0.75  (25% redevelopment, 100% new development)

Water Quality Volume (WQv)  WQv=(P*Rv*A)/12

  Where: P=90% Rainfall Event Number  P= 1
  Rv= 0.05+0.009*(I)  Rv= 0.24
  IC=Impervious Cover, Acres  IC= 11.19
  I=Impervious Cover (%)  I= 21
  A=Runoff Area, Acres  A= 53

  WQv (ac-ft)= 1.060
  WQv (cf)= 46,174

RRv PROVIDED FOR PROPOSED DEVELOPMENT AREA (See NYSDEC worksheets)
  WQv, cf  RRv, cf
  Min. RRv Req'd, cf = 0  RRv, none required 0  0
  Min. RRv Req'd, ac-ft = 0.000  WQv, Wet Pond 46,174  0

  TOTAL, cf 46174  0
  TOTAL, ac-ft 1.060  0.000

WQ & RR SUMMARY (ac-ft):

TOTAL WATER QUALITY PROVIDED FOR PROPOSED DEVELOPMENT AREA  1.060

IS WATER QUALITY VOLUME REQUIREMENT MET?  Yes
(WQv provided equal to or greater than WQv required)

IS RUNOFF REDUCTION VOLUME REQUIREMENT MET?  Yes
(RRv provided equal to or greater than Min. RRv required)