WAVES AE
Civil Engineering · Site Development
255 Rounds Avenue, Buffalo, New York 14215 · 585-305-5199 · [email protected]

July 28, 2026
Chairperson and Members of the Planning Board
Town of West Seneca
Town Hall, 1250 Union Road
West Seneca, New York 14224
RE:  Letter of Intent — Site Plan Review
  4350 Seneca Street Building Addition
  4350 Seneca Street, West Seneca, New York 14224 · SBL No. 135.17-3-8.2
  C-2 Commercial District · Applicant: Havens Holding Group
Dear Chairperson and Members of the Board:
On behalf of Havens Holding Group, this letter accompanies the site plan application for a building addition at 4350
Seneca Street and sets out the intent of the proposed work.
Existing conditions. The property is an existing developed commercial parcel improved with a one-story building of
approximately 3,000 square feet occupied by a New York State licensed farm brewery and tasting room, together with
paved parking, circulation, and an outdoor patio and garden area. The facility hosts an average of four staff on site
during peak working hours and approximately 65 guests per day.
Proposed action. The applicant proposes a two-story addition constructed over and adjacent to the existing building,
providing 1,902 square feet of first-floor production area and 2,500 square feet of second-floor office and interior
storage area. More than 90 percent of the addition footprint lies on previously disturbed ground.
Intent. The addition houses existing operations in a larger footprint; it does not expand them. Annual production
remains at approximately 650 to 700 barrels. The replacement equipment installed in the new space reduces energy
consumption, water usage, and production time. The added area provides clear working separation between equipment
for safer operations, floor area for the larger footprint of the newer equipment, interior storage for materials presently
kept elsewhere, and an area of dedicated office and meeting space for staff who at present work from the tasting room.
Peak on-site staffing, occupant loads, and average daily patronage are unchanged, and no increase in trip generation is
anticipated. The applicant has secured a grant from Empire State Development toward furniture, fixtures, and
equipment for the brewery space, which advanced the decision to proceed with the expansion.
Zoning. The property is zoned C-2 Commercial District under Chapter 120 of the Town Code. The addition continues
the established use of the property. No rezoning, use variance, or area variance is requested. Dimensional conformance
is demonstrated in the zoning data block on the accompanying site plan.
Utilities. Existing services are retained without modification. Analyses accompanying this submission demonstrate that
the existing one-inch domestic water service is adequate for the proposed occupancy-managed demand, and that the
existing four-inch sanitary lateral and the receiving 15-inch Town main have adequate capacity. The recently upgraded
two-inch gas service is likewise adequate; no additional gas volume is required. Sanitary loading is unchanged because
occupancy and production volume are unchanged. No fire suppression service is required.
Environmental review. A completed Short Environmental Assessment Form, Part 1, accompanies this submission. The
addition exceeds by 402 square feet the 4,000 square foot threshold at 6 NYCRR 617.5(c)(9), below which such non-
residential expansion is a Type II action requiring no environmental review; the action is therefore Unlisted by a narrow
margin. We would welcome the Board's or staff's guidance as to whether the Town has adopted a supplemental Type II
list under 6 NYCRR 617.5(b) under which an action of this nature would also qualify, obviating environmental review
altogether. Should review be required, then on the record presented — a footprint more than 90 percent on previously
disturbed ground, no change of use, no increase in occupancy, production volume, or utility demand, and reduced
energy and water consumption — we respectfully request that the Board declare itself lead agency and adopt a Negative
Declaration at the same meeting, which the limited scope of the action should readily permit.
We respectfully request that this application be placed on the agenda for the Board's meeting of August 13, 2026. I will
attend to answer questions, and would welcome the opportunity to address any staff or Board comments in advance.
Respectfully submitted,
Jason Havens, P.E.
Principal Civil Design · Waves AE
New York State Professional Engineer License No. 090335
Enclosures: Site plan set · Zoning data block · Water service sizing calculation · Sanitary sewer capacity analysis · Short EAF Part 1 with
Mapper Summary Report

  Page 31 of 84