Rustys_Pre-Construction - Copy  Type II 24-hr 10-yr Rainfall=3.14"
Prepared by Waves AE  Printed 7/29/2026
HydroCAD® 10.20-7a s/n 13900 © 2025 HydroCAD Software Solutions LLC  Page 9

  Summary for Subcatchment 2: Subcat 2

[46] Hint: Tc=0 (Instant runoff peak depends on dt)

Runoff  =  1.39 cfs @ 11.89 hrs, Volume=  2,309 cf, Depth> 1.58"
  Routed to Link AP2 : BASIN

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Type II 24-hr 10-yr Rainfall=3.14"

  Area (sf)  CN  Description
  9,291  73  Brush, Good, HSG D
  4,967  98  Paved parking, HSG D
  3,277  98  Unconnected pavement, HSG D
  17,535  85  Weighted Average
  9,291  52.99% Pervious Area
  8,243  47.01% Impervious Area
  3,277  39.75% Unconnected

  Subcatchment 2: Subcat 2
  Hydrograph

  Runoff
  1.39 cfs
  Type II 24-hr
  10-yr Rainfall=3.14"
  Runoff Area=17,535 sf
  1
  Runoff Volume=2,309 cf
  Flow (cfs)

  Runoff Depth>1.58"
  Tc=0.0 min
  CN=85

  0
  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20
  Time (hours)

  Page 59 of 84