William Smith May 26, 2026 Page 2 https://dec.ny.gov/regulatory/permits-licenses/waterways-coastlines- wetlands/freshwater-wetlands#Determine 2. Please note that Big Sister Creek has a water classification and standard of C(T), pursuant to 6 NYCRR Part 835, Item 2. Therefore, any physical alteration (i.e. land clearing, filling, drainage pipe/ditch installation, etc.) to the bed or banks (within 50 feet of the stream) will require an Article 15, Title 5, Protection of Waters Permit from the NYSDEC. 3. We have reviewed the available information in the New York State Natural Heritage Program databases on known occurrences of rare or state-listed animals and plants, of significant natural communities, and other significant habitats. Bald Eagle (Haliaeetus leucocphalus), a NYS listed threatened species, was last identified in 2019 year in the Town of Evans. For most sites, comprehensive field surveys have not been conducted. We cannot provide a definitive statement as to the presence or absence of all rare or state-listed species or significant natural communities. This information should not be substituted for on-site surveys that may be required for environmental impact assessment. Depending on the nature of the project and the conditions at the project site, further information from on-site surveys or other sources may be required to fully assess impacts on biological resources. 4. Please recognize that this proposed project is defined as a Sanitary Sewer Extension and will require approval from the Erie County Department of Environment and Planning, Division of Sewerage Management (ECDSM), as well as approval from the Erie County Department of Health, 503 Kensington Avenue, Buffalo, New York 14214, telephone: 716/961-6800, which acts as our agent and will be the approving agency. This Sanitary Sewer Extension project will also require stamped Professional Engineering Certification that the downstream capacity analysis [DSCA] and the proposed infiltration and inflow [I/I] mitigation work submitted for the project are in accordance with appropriate NYSDEC and ECDSM guidelines and standards. A detailed Downstream Sewer Capacity Analysis must be performed and submitted for the project as part of the Project’s Engineering Report. Recent wet weather flow monitoring data and proposed new development flow should be analyzed relative to theoretical capacity at key nodes in the downstream sewer system and at pump stations (if any) to determine if capacity exists. Recent wet weather system flow data can consist of: Comprehensive information from recent Sanitary Sewer System Evaluation Studies, or Wet weather data collected at (minimum of 3) key downstream nodes specified by the municipality. o This dated information can consist of instantaneous flow measurements or continuous flow or sewer depth measurements obtained during significant wet weather events, preferably during high groundwater conditions. Peak sewer flow recording methods are an acceptable method to collect this information. o Depth or flow measurements should continue until a significant wet weather event occurs, but would not have to extend beyond three